N2XOH Cable Triple

N2XOH Freetox Triple cable is a high-performance, halogen-free power cable featuring three copper conductors with XLPE insulation, designed for critical installations where fire safety, low smoke emission, and minimal toxic gas release are essential requirements in industrial and commercial environments.

  • N2xoh Cable Triple

N2XOH Cable Triple


Cable Freetox N2XOH Triple 0.6/1 kV

  • Rated Voltage 0.6/1kV
  • Conductor Material Plain annealed copper
  • Insulation Material XLPE
  • Sheath LSZH
  • Number of cores Triplex
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

Cable Freetox N2XOH Triple Application

N2xoh cable suitable in low voltage power distribution networks. Special application in places with poor ventilation, direct application in places with public attendance high. It can be installed in ducts, ladders or cable trays, in dry, humid or wet environments.

Cable Freetox N2XOH Triple Standards:

National : NTP-IEC 60228; NTP-IEC 60502-1

International : IEC 60228; IEC 60332-1; IEC 60332-3-24 Cat.C; IEC 60502-1; IEC 60684-2; IEC 60754-2; IEC 60811-1-1; IEC 60811-1-2; IEC 60811-1-3; IEC 60811-1-4; IEC 60811-2-1; IEC 60811-3-1; IEC 61034

Construction

Cable Freetox N2XOH Triple Construction

Cable Freetox N2XOH Triple Construction

1. Conductor: Soft copper, class 2.

2. Insulation: Cross linked polyethylene XLPE.

3. Outer sheath: Halogen free thermoplastic compound HFFR-UV.

4. Tape: Polyester tape.

Colour:

Insulation: Natural.

TECHNICAL DATA :

Main characteristics:

The cable has excellent electric properties. The cross-linked polyethylene insulation allows a higher power capacity current under any operation conditions, lower dielectric losses, high insulation resistance. The outer sheath has the following characteristics: Fire retardant, low emission dense smoke and halogen free. Sunlight resistance.

Rated voltage:0.6/1kV
Test voltage:3.5kV A.C.
Maximum conductor temperature : 90°C.
Maximum operating temperature:130 °C
Short-circuit max. conductor temperature:250 °C

PARAMETER :

N2XOH TRIPLE CABLES Design Parameters

No. Conductor x Section No x mm2Minimum number of wiresConductor diameter mmInsulation thickness mmSheath thickness mmOutside diameter mmNominal Weight kg/kmCurrent capacity (*)
Buried AAir ADuct A
3-1x472,50,71,47,5x23255655555
3-1x673,00,71,48,0x24330856568
3-1x1073,80,71,48,5x264501159095
3-1x1674,80,71,410x30660155125125
3-1x2576,00,91,412x36990200160160
3-1x3577,20,91,413x391 260240200195
3-1x50198,81,01,415x451 680280240230
3-1x701910,41,11,417x512 310345305275
3-1x951912,01,11,519x573 120415375330
3-1x1203713,51,21,521x633 840470435380
3-1x1503715,21,41,623x694 710520510410
3-1x1853716,81,61,625x755 850590575450
3-1x2403719,21,71,728x847 560690690525
3-1x3003721,51,81,831x939 420775790600
3-1x4006124,92,01,935x10512 030895955680
3-1x5006127,82,22,039x11715 1801 0101100700
Need Help?