AAC-All Aluminum Stranded Conductor CSA C49

AAC All Aluminum Conductor to CSA C49 is a bare overhead conductor widely used in Canadian power transmission lines. It's a popular choice due to its simple construction, ease of installation, and low cost. The conductor is suitable for a wide range of applications, including installations across rivers and valleys.

  • Aac All Aluminum Stranded Conductor Csa C49

AAC-All Aluminum Stranded Conductor CSA C49


AAC CSA C 49 Stranded Aluminum Conductors Canadian Sizes

  • Nominal Area circular and sectional
  • Sectional area 6AWG to 3500MCM
  • Insulation N/A
  • Standard ASC CSA C49


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

AAC (All Aluminum Conductor) to CSA C49 is a bare overhead conductor widely used in Canadian power transmission lines. It's a popular choice due to its simple construction, ease of installation, and low cost. The conductor is suitable for a wide range of applications, including installations across rivers and valleys.


Key Specifications

  • Standard: CSA C49, which covers stranded aluminum conductors for Canadian sizes.
  • Conductor Material: Consists of concentric-lay-stranded hard-drawn 1350-H19 aluminum wires with a minimum purity of 99.55%.
  • Construction: The wires are helically wrapped around a central core, with each successive layer having six more wires than the one beneath it.
  • Insulation: None; this is a bare conductor.
  • Nominal Area: The conductor is available in a wide range of sizes, from 6 AWG to 3500 MCM.
  • Temperature Rating: Designed for continuous use at temperatures up to C.

Application Classes

The conductor's flexibility is defined by its class:

  • Class AA: Used for bare overhead lines, this is the least flexible class.
  • Class A: Used for conductors with weather-resistant coverings or where greater flexibility is needed.
  • Compact Strand: An option for bare overhead applications or with weather-resistant coverings, offering increased flexibility.

Parameter Table

Code WordAWG & MCMSectional Area (mm²)StrandingOverall Diameter (mm)Breaking Load (kN)D.C. Resistance (/km)Current Rating (A)
Rose421.167/1.96 mm5.894.11.35110
Lily326.657/2.20 mm6.615.01.072124
Iris233.617/2.47 mm7.426.20.8497136
Pansy142.397/2.77 mm8.337.60.6739157
Poppy1/053.487/3.12 mm9.369.20.5341180
Aster2/067.427/3.50 mm10.5111.60.4236207
Phlox3/085.037/3.93 mm11.8214.10.3362237
Oxlip4/0107.27/4.41 mm13.2517.70.2664273
Valerian250126.719/2.91 mm14.5722.30.2274305
Daisy266.8135.167/4.96 mm14.922.40.2113313
Tulip336.4170.4519/3.38 mm16.9129.40.1638364
Canna397.5201.4219/3.67 mm18.3634.00.1427401
Cosmos477241.6819/4.02 mm20.1240.00.1188447
Zinnia500253.3519/4.12 mm20.6641.90.1132459
Dahlia556.528219/4.34 mm21.7346.70.1018489
Orchid636322.2637/3.33 mm23.3155.60.0896531
Violet715.5362.5837/3.53 mm24.7462.50.0797570
Arbutus795402.8437/3.72 mm26.0668.10.0715605
Magnolia954483.4237/4.07 mm28.5580.00.0597675
Marigold1113563.9361/3.43 mm30.8997.20.0512738
Narcissus1272644.5161/3.66 mm33.02108.80.0457797
Carnation1431725.1661/3.89 mm35.03119.90.0408854
Corepsis1590.5805.6861/4.09 mm36.91133.20.0358907
-17001700861.4261/4.23 mm38.15142.60.0335942
-18001800912.0661/3.57 mm39.28153.90.0316975
Need Help?