Aerial Insulated Cable (IEC 60502-2)

This is a medium-voltage aerial insulated cable that complies with the IEC 60502-2 standard. It's designed for overhead power distribution at 10kV. Conductors can be made of aluminum, aluminum alloy, or copper, with insulation and a semi-conductive shield. The conductors must be installed on insulators or spacers appropriate for the service voltage.

  • Aerial Insulated Cable Iec 60502 2

Aerial Insulated Cable (IEC 60502-2)


Aerial Insulated Cable (IEC 60502-2)

  • Conductor Circular compressed aluminum, aluminum-alloy, copper.
  • Conductor shield Semi-conducting cross-linked polyethylene.
  • Insulation Cross-linked polyethylene (Natural)
  • Sheath PE & XLPE
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

This is a medium-voltage aerial insulated cable that complies with the IEC 60502-2 standard. It's designed for overhead power distribution at 10kV. Conductors can be made of aluminum, aluminum alloy, or copper, with insulation and a semi-conductive shield. The conductors must be installed on insulators or spacers appropriate for the service voltage.

Applications

This cable is used for the distribution of electrical energy in overhead (aerial) installations. When installing, it is essential to use appropriate insulators and spacers. The dielectric compatibility of all components (covering, insulator, spacer, etc.) should be taken into consideration for the service voltage.

Aerial Insulated Cable (IEC 60502-2) SPECIFICATION

GB/T 14049 (Equal to IEC 60502-2) Aerial Insulated Cables For Rated Voltage of 10kV

TypeNumber of CoresNominal Size (mm²)
CU/XLPE, AAC/XLPE, AAAC/XLPE110 ~ 400
325 ~ 400
3 + k(A) or 3 + k(B)25 ~ 400; k: 25 ~ 120
CU/PE, AAC/PE, AAAC/PE110 ~ 400
325 ~ 400
3 + k(A) or 3 + k(B)25 ~ 400; k: 25 ~ 120

Parameter-Copper Conductor

10kV Aerial Insulated Cables

Nominal SizeMin. No.
of Wires
Approx. Diameter of ConductorMin.
Thickness of Conductor screen
(Approx.)
Nominal Thickness of InsulationNominal Thickness of Insulation ScreenMin. Breaking Load
ReducedNominalHard CopperSoft CopperHard Copper
mm²No.mmmmmmmmΩ/kmΩ/kmN
1063.80.5-3.4-1.830-
1664.80.5-3.4-1.150-
2566.00.52.53.40.7490.7278465
3567.00.52.53.40.5400.52411731
5068.30.52.53.40.3990.38716052
701210.00.52.53.40.2760.26823461
951511.60.62.53.40.1990.19331759
1201813.00.62.53.40.1580.15339911
1501814.60.62.53.40.128-49505
1853016.20.62.53.40.1021-61846
2403418.40.62.53.40.0777-79823
3003420.60.62.53.40.0619-99788
4005323.80.62.53.40.0484-133040