Aerial Insulated Cable (IEC 60502-2)

The Aerial Insulated Cable designed according to IEC 60502-2 is a type of overhead power cable with extruded insulation suitable for medium-voltage applications. It is constructed to ensure reliable electrical performance, mechanical strength, and environmental durability when installed in outdoor aerial networks.

  • slide

Aerial Insulated Cable (IEC 60502-2)


Aerial Insulated Cable (IEC 60502-2)

  • Conductor Circular compressed aluminum, aluminum-alloy, copper.
  • Conductor shield Semi-conducting cross-linked polyethylene.
  • Insulation Cross-linked polyethylene (Natural)
  • Sheath PE & XLPE
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

Aerial Insulated Cable (IEC 60502-2) Application:

Aerial Insulated Cables with voltages of 10kV.The products primarily used for the distribution of electrical energy under normal conditions of overhead (aerial) installations.The conductors must be installed on insulators and/or spacers adequate for the service voltage. The user may want to give consideration to the dielectric compatibility of the covering, insulator, spacer etc.

>Aerial Insulated Cable (IEC 60502-2) Description

The conductors are stranded,circular compressed aluminum, aluminum-alloy, copper. The conductor screen is the extruded Semi-conducting conductor shield in Black. And the outer Insulation is mainly thermoplastic polyethylene (PE) or cross-linked polyethylene (XLPE) in Black with Weather or UV resistant. This standard covers both thermoplastic and cross linked polyethylene constructions, rated for 75°C or 90°C normal service temperature.

>Aerial Insulated Cable (IEC 60502-2) SPECIFICATION

GB/T 14049 (Equal to IEC 60502-2) Aerial Insulated Cables For Rated Voltage of 10kV

Type No. of Cores Nominal size
mm²
CU/XLPE,AAC/XLPE,AAAC/XLPE 1 10 ~ 400
3 25 ~ 400
3+k(A) or 3+k(B) 25 ~ 400 ; k:25~120
CU/PE,AAC/PE,AAAC/PE,CU/XLPE,AAC/XLPE,AAAC/XLPE 1 10 ~ 400
AAC/XLPE,AAAC/XLPE 3 25 ~ 400
3+k(A) or 3+k(B) 25 ~ 400 ; k:25~120
The k is a load-bearing core. (A) means steel carrying stranded wire, (B) means aluminum alloy carrying stranded wire.

Parameter-Copper Conductor

10kV Aerial Insulated Cables

Nominal Size Min. No.
of Wires
Approx. Diameter of Conductor Min.
Thickness of Conductor screen
(Approx.)
Nominal Thickness of Insulation Nominal Thickness of Insulation Screen Min. Breaking Load
Reduced Nominal Hard Copper Soft Copper Hard Copper
mm² No. mm mm mm mm Ω/km Ω/km N
10 6 3.8 0.5 - 3.4 - 1.830 -
16 6 4.8 0.5 - 3.4 - 1.150 -
25 6 6.0 0.5 2.5 3.4 0.749 0.727 8465
35 6 7.0 0.5 2.5 3.4 0.540 0.524 11731
50 6 8.3 0.5 2.5 3.4 0.399 0.387 16052
70 12 10.0 0.5 2.5 3.4 0.276 0.268 23461
95 15 11.6 0.6 2.5 3.4 0.199 0.193 31759
120 18 13.0 0.6 2.5 3.4 0.158 0.153 39911
150 18 14.6 0.6 2.5 3.4 0.128 - 49505
185 30 16.2 0.6 2.5 3.4 0.1021 - 61846
240 34 18.4 0.6 2.5 3.4 0.0777 - 79823
300 34 20.6 0.6 2.5 3.4 0.0619 - 99788
400 53 23.8 0.6 2.5 3.4 0.0484 - 133040