NFC 33-209 Aerial Bundle Conductor ABC Cable 2x25mm2

This NFC 33-209 Aerial Bundle Conductor (ABC) Cable 2x25mm² is a low-voltage power cable designed for overhead distribution lines. It has two 25mm² stranded aluminum conductors with XLPE insulation. The conductors are twisted together to form a compact and durable cable bundle. It complies with the National French Standard NFC 33-209.

  • Nfc 33 209 Aerial Bundle Conductor Abc Cable 2x25mm2

NFC 33-209 Aerial Bundle Conductor ABC Cable 2x25mm2


2x25mm2 Twist Cable Overhead Line with Aluminum Conductor XLPE Insulation

  • Conductor Stranded Round Aluminum Conductor
  • Insulation XLPE
  • Voltage 0.6/1kV
  • Number of cores 2 Core
  • Package 100 Meters One Roll with Export Wooden Case & Pallet


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

This NFC 33-209 Aerial Bundle Conductor (ABC) Cable 2x25mm² is a low-voltage power cable designed for overhead distribution lines. It has two 25mm² stranded aluminum conductors with XLPE insulation. The conductors are twisted together to form a compact and durable cable bundle. It complies with the National French Standard NFC 33-209.


Applications

This 2x25mm² ABC cable is used to supply power from a pole-mounted transformer to a user's service head. It is suitable for applications with a phase-to-phase voltage of 600V or less, where the conductor temperature doesn't exceed 90°C.


Standards Compliance

The cable is manufactured and tested according to the following international standards:

  • Aerial Bundled Conductors: National French Standard NFC 33-209
  • Insulation and Extruded Cables: IEC 60502-1

Construction Details

2 core ABC Cable Construction

The construction of the 2-core ABC cable includes:

  • Phase Conductor: Round stranded compressed aluminum (RM).
  • Insulation: Black XLPE.
  • Assembly: The cores are stranded together with a right-hand lay.

Technical Data & Parameters

ParameterValue
Standards ReferenceIEC 60502-1, NFC 33-209
Rated Voltage0.6/1 kV
Test Voltage4 kV (Veff)
Type of Cable2x25mm²
Conductor MaterialStranded Aluminum wire
Stranding (No. of wires)7
Approx. Diameter of Conductor6.0 mm
Insulation MaterialBlack XLPE
Nominal Thickness of Insulation1.4 mm
Approx. Diameter of Insulated Conductor8.8 mm
Approx. Overall Diameter of Cable18.0 mm
Max. DC Resistance @ 20°C1.2 /km
Approx. Weight of Cable202 kg/km
Laying Temperature (min.)-5°C
Operating Temperature-15°C to +90°C
Conductor Temperature (max.)+90°C
Short-Circuit Temperature (max.)+250°C for 5 seconds
Bending Radius (min.)15 x Ø of cable
Need Help?