2-Layer 15kV AAC Tree Wire Spacer Cable

The 2-Layer 15kV AAC (All Aluminum Conductor) Tree Wire Spacer Cable is a specialized overhead distribution cable designed for urban and suburban power lines where aesthetics, safety, and reliability are important. It features a layered construction with spacers, providing electrical insulation, mechanical strength, and proper conductor spacing to prevent faults and improve line performance.

  • slide

2-Layer 15kV AAC Tree Wire Spacer Cable


2-Layer 15kV AAC Tree Wire Spacer Cable

  • Conductor 1350-H19 aluminum (AAC)
  • Insulation Cross-linked polyethylene(XLPE)
  • Sheath High-density track-resistant Polyethylene(HDPE)
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

2-Layer 15kV AAC Tree Wire Spacer Cable Application

The tree wire is used for primary and secondary overhead distribution where limited space is available or desired for rights-of-way. Installed the same as bare conductors, however, covering is effective in preventing direct shorts and instantaneous flashovers with other objects. The close-proximity configuration minimizes the amount of space and hardware required for line installation, making it particularly useful in congested areas such as alleyways or tight corridors.

2-Layer 15kV AAC Tree Wire Spacer Cable Standard

ICEA S-121-733, ASTM B231, ASTM B399, ASTM B232

Construction

2-Layer 15kV AAC Tree Wire Spacer Cable Construction
The tree wire is designed with concentrically stranded conductors - AAC (1350-H19) which are either compressed or compact depending on conductor size, available with AAAC or ACSR. The conductors can be covered with high-density track-resistant Polyethylene (HDTRPE) or track-resistant crosslinked Polyethylene (XLPE) insulation to meet different applications.

TECHNICAL DATA :

Temperature :

- Normal operation 90°C.

- Emergency over load conditions 130°C.

- Short circuit conditions 250°C.
Voltage rating :
15 kV phase to phase AC TESTING VOLTAGE : 27 kV for 5 minutes

2-Layer 15kV AAC Tree Wire Spacer Cable
Size  
(AWG or kcmil)
Stranding Conductor Covering Thickness Cable O.D. Rated Weight per
Diameter (mils) Strength 1000 ft.
(mils) Inner Layer Outer Layer (mils) (lbs) (lbs)
1/0 7 336 75 75 636 1791 196
2/0 7 376 75 75 676 2259 230
3/0 7 423 75 75 723 2736 272
4/0 7 475 75 75 775 3447 325
266.8 19 537 75 75 837 4473 387
336.4 19 603 75 75 903 5535 466
397.5 19 659 75 75 959 6399 535
477 19 722 75 75 1022 7524 623
556.5 37 780 75 75 1080 8946 708
636 37 835 75 75 1135 10260 794