2-Layer 15kV ACSR Tree Wire Spacer Cable

The 2-Layer 15kV ACSR (Aluminum Conductor Steel Reinforced) Tree Wire Spacer Cable is specially designed for overhead distribution lines requiring high strength, reliability, and optimal conductor spacing. Its layered construction with spacers ensures proper separation between conductors, reduces electrical interference, and enhances line stability and safety, especially in urban and suburban environments.

  • 2 Layer 15kv Acsr Tree Wire Spacer Cable

2-Layer 15kV ACSR Tree Wire Spacer Cable


2-Layer 15kV ACSR Tree Wire Spacer Cable

  • Conductor ACSR
  • Insulation Cross-linked polyethylene(XLPE)
  • Sheath High-density track-resistant Polyethylene(HDPE)
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

2-Layer 15kV ACSR Tree Wire Spacer Cable Application

The tree wire is used for primary and secondary overhead distribution where limited space is available or desired for rights-of-way. Installed the same as bare conductors, however, covering is effective in preventing direct shorts and instantaneous flashovers with other objects. The close-proximity configuration minimizes the amount of space and hardware required for line installation, making it particularly useful in congested areas such as alleyways or tight corridors.

2-Layer 15kV ACSR Tree Wire Spacer Cable Standard

ICEA S-121-733, ASTM B231, ASTM B399, ASTM B232

Construction

2-Layer 15kV ACSR Tree Wire Spacer Cable Construction
The tree wire is designed with concentrically stranded conductors - AAC (1350-H19) which are either compressed or compact depending on conductor size, available with AAAC or ACSR. The conductors can be covered with high-density track-resistant Polyethylene (HDTRPE) or track-resistant crosslinked Polyethylene (XLPE) insulation to meet different applications.

TECHNICAL DATA :

Temperature :

- Normal operation 90°C.

- Emergency over load conditions 130°C.

- Short circuit conditions 250°C.

Voltage rating :

15 kV phase to phase AC TESTING VOLTAGE : 27 kV for 5 minutes

2-Layer 15kV ACSR Tree Wire
2-Layer 15kV ACSR Tree Wire
Size
(AWG or kcmil)
Stranding Conductor Diameter
(mils)
Covering Thickness (mils) Cable
O.D.
Rated Strength
(lbs)
Weight per 1000 ft.
(lbs)
Inner Layer Outer Layer
4 6/1 250 75 75 550 1767 136
2 6/1 316 75 75 616 2708 184
1/0 6/1 398 75 75 698 4161 255
2/0 6/1 447 75 75 747 5045 303
3/0 6/1 502 75 75 802 6289 362
4/0 6/1 563 75 75 863 7933 432
266.8 18/1 609 75 75 909 6536 441
266.8 26/7 642 75 75 942 10735 452
336.4 18/1 684 75 75 984 8246 536
336.4 26/7 720 75 75 1020 13395 555
336.4 30/7 741 75 75 1041 16435 621
397.5 18/1 743 75 75 1043 9443 611
397.5 24/7 772 75 75 1072 13870 609
397.5 26/7 783 75 75 1083 1545 645
477 24/7 846 75 75 1146 16340 719
477 26/7 858 75 75 1158 18525 762
477 30/7 883 75 75 1183 22610 854
556.5 18/1 879 75 75 1179 13015 813
556.5 24/7 914 75 75 1214 18810 828
556.5 26/7 927 75 75 1227 21470 878
636 18/1 940 75 75 1240 14915 912
636 24/7 977 75 75 1277 20900 936
636 26/7 990 75 75 1290 23940 993
795 26/7 1108 80 75 1428 29925 1234
795 45/7 1063 80 80 1383 20995 1031