3-Layer 25kV AAAC Tree Wire Spacer Cable

The 3-Layer 25kV AAAC Tree Wire Spacer Cable is designed for overhead electrical distribution lines operating at 25kV. Its three-layer layered configuration with spacers ensures optimal conductor spacing, mechanical strength, and electrical performance, making it suitable for urban, suburban, and environmentally sensitive overhead power systems.

  • slide

3-Layer 25kV AAAC Tree Wire Spacer Cable


3-Layer 25kV AAAC Tree Wire Spacer Cable

  • Conductor 6201-81 aluminum alloy (AAAC)
  • Insulation Cross-linked polyethylene(XLPE)
  • Sheath High-density track-resistant Polyethylene(HDPE)
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

3-Layer 25kV AAAC Tree Wire Spacer Cable Application

The tree wire is used for primary and secondary overhead distribution where limited space is available or desired for rights-of-way. Installed the same as bare conductors, however, covering is effective in preventing direct shorts and instantaneous flashovers with other objects. The close-proximity configuration minimizes the amount of space and hardware required for line installation, making it particularly useful in congested areas such as alleyways or tight corridors.

3-Layer 25kV AAAC Tree Wire Spacer Cable Standard

ICEA S-121-733, ASTM B231, ASTM B399, ASTM B232

Construction

3-Layer 25kV AAAC Tree Wire Spacer Cable Construction
The tree wire is designed with concentrically stranded conductors - AAC (1350-H19) which are either compressed or compact depending on conductor size, available with AAAC or ACSR. The conductors can be covered with high-density track-resistant Polyethylene (HDTRPE) or track-resistant crosslinked Polyethylene (XLPE) insulation to meet different applications.

TECHNICAL DATA :

Temperature :

- Normal operation 90°C.

- Emergency over load conditions 130°C.

- Short circuit conditions 250°C.

Voltage rating :

15 kV phase to phase AC TESTING VOLTAGE : 27 kV for 5 minutes

3-Layer 25kV AAAC Tree Wire Spacer Cable
Size
(kcmil)
Equivalent AAC
 (AWG or kcmil)
Stranding Conductor
Diameter
(mils)
Covering Thickness (mils) Cable O.D.
(mils)
Rated Strength
(lbs)
Weight per 1000 ft.
(lbs)
Conductor Shield Inner Layer Outer Layer
48.69 4 7 250 15 125 125 780 1584 225
77.47 2 7 316 15 125 125 846 2520 275
123.3 1/0 7 398 15 125 125 928 4014 348
155.4 2/0 7 447 15 125 125 977 4851 396
195.7 3/0 7 502 15 125 125 1032 6111 454
246.9 4/0 7 563 15 125 125 1093 7704 525
312.8 266.8 19 642 15 125 125 1172 9900 611
394.5 336.4 19 720 15 125 125 1251 11970 716
465.4 397.5 19 783 15 125 125 1313 14040 805
559.5 477 19 858 20 125 125 1398 16920 932
652.4 556.5 19 927 20 125 125 1467 19710 1044
740.8 636 37 990 20 125 125 1530 21960 1148
927.2 795 37 1108 20 125 125 1648 27450 1389