3-Layer 35kV AAAC Tree Wire Spacer Cable

The 3-Layer 35kV AAAC Tree Wire Spacer Cable is an overhead distribution conductor designed for voltages up to 35kV. Its multi-layer construction combined with spacers ensures optimal conductor separation, mechanical strength, and electrical performance, suitable for urban, suburban, and environmentally sensitive overhead power lines.

  • slide

3-Layer 35kV AAAC Tree Wire Spacer Cable


3-Layer 35kV AAAC Tree Wire Spacer Cable

  • Conductor 6201-81 aluminum alloy (AAAC)
  • Insulation Cross-linked polyethylene(XLPE)
  • Sheath High-density track-resistant Polyethylene(HDPE)
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

3-Layer 35kV AAAC Tree Wire Spacer Cable Application

The tree wire is used for primary and secondary overhead distribution where limited space is available or desired for rights-of-way. Installed the same as bare conductors, however, covering is effective in preventing direct shorts and instantaneous flashovers with other objects. The close-proximity configuration minimizes the amount of space and hardware required for line installation, making it particularly useful in congested areas such as alleyways or tight corridors.

3-Layer 35kV AAAC Tree Wire Spacer Cable Standard

ICEA S-121-733, ASTM B231, ASTM B399, ASTM B232

Construction

3-Layer 35kV AAAC Tree Wire Spacer Cable Construction
The tree wire is designed with concentrically stranded conductors - AAC (1350-H19) which are either compressed or compact depending on conductor size, available with AAAC or ACSR. The conductors can be covered with high-density track-resistant Polyethylene (HDTRPE) or track-resistant crosslinked Polyethylene (XLPE) insulation to meet different applications.

TECHNICAL DATA :

Temperature :

- Normal operation 90°C.

- Emergency over load conditions 130°C.

- Short circuit conditions 250°C.

Voltage rating :

15 kV phase to phase AC TESTING VOLTAGE : 27 kV for 5 minutes

3-Layer 35kV AAAC Tree Wire Spacer Cable
Size
 (kcmil)
Equivalent AAC
 (AWG or kcmil)
Stranding Conductor Diameter
(mils)
Covering Thickness (mils) Cable O.D.
(mils)
Rated Strength
(lbs)
Weight per 1000 ft.
(lbs)
Conductor Shield Inner Layer Outer Layer
48.69 4 7 250 15 175 125 880 1584 278
77.47 2 7 316 15 175 125 946 2520 333
123.3 1/0 7 398 15 175 125 1028 4014 411
155.4 2/0 7 447 15 175 125 1077 4851 462
195.7 3/0 7 502 15 175 125 1132 6111 523
246.9 4/0 7 563 15 175 125 1193 7704 598
312.8 266.8 19 642 15 175 125 1272 9900 689
394.5 336.4 19 720 15 175 125 1351 11970 799
465.4 397.5 19 783 15 175 125 1412 14040 892
559.5 477 19 858 20 175 125 1498 16920 1024
652.4 556.5 19 927 20 175 125 1567 19710 1141