1.5mm 2.5mm 12 Core Steel Wire Armoured SWA Cable

This is a 12-core Steel Wire Armoured (SWA) control cable with PVC insulation and PVC sheathing, rated for 0.6/1kV. The cable cores are 1.5mm² and 2.5mm², typically used for control and instrumentation purposes in industrial settings. The steel wire armouring provides mechanical protection against external physical damage, making it suitable for installation in harsh environments, underground, or outdoor locations. The PVC insulation and sheath offer good chemical, moisture, and abrasion resistance, ensuring reliable performance and long-term durability of the electrical system.

  • slide

1.5mm 2.5mm 12 Core Steel Wire Armoured SWA Cable


PVC Insulated, PVC Sheathed Armoured 12 Core Control Cable 0.6/1kV

  • Rated Voltage 600/1000 Volts
  • Conductor Material Copper
  • Insulation PVC
  • Package Export wooden drum


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

1.5mm 2.5mm 12 Core Steel Wire Armoured SWA Cable Application

2.5mm 12 Core Armoured Cable is commonly found supplying mains voltage electricity to powered devices and networks. For example, it could be used to power outdoor buildings such as garden sheds or workshops as well as garden features such as jacuzzi/hot tubs.The cable contains a steel wire armour, meaning it provides a mechanical protection for the insulating layers underneath. This also enables the cable to have higher pulling loads, making it perfectly suitable for dispensing from a cable drum on a building site, etc. It’s construction is commonly identified by the plain annealed stranded copper for the cores, the PVC (Polyvinyl Chloride) for the bedding and sheathing, armour made from steel wire and PVC (Polyvinyl Chloride) for the insulation. The Steel Wire can also be used as a CPC (Circuit Protective Conductor), meaning the armour can be used an earth for the cable. This means that even though the cable has an earth core, it is still protected, meaning it abides by all health and safety regulations.

1.5mm 2.5mm 12 Core Steel Wire Armoured SWA Cable Standard

MS 2103 / IEC 60502 – 1

CONSTRUCTION :

Conductor : Plain Annealed Copper Conductor
Insulation : PVC (Polyvinyl Chloride) PVC/A
Colour of Insulation : White with black numbering
Bedding : PVC (Polyvinyl Chloride) ST1
Armoured : Galvanised Steel Wires
Sheath : PVC (Polyvinyl Chloride) ST1
Voltage : 600/1000 Volts

TECHNICAL

Nominal Voltage : U / U 0.6 / 1kV O
Insulation Resistance : Min. 20 GΩ x cm
Temperature Range : Flexing -5°C to +70°C. Fixed installation -30°C to +70°C
Minimum Bending Radius : Flexing 15 x cable ø. Fixed installation 4 x cable ø
Test Voltage : 4000V
Breakdown Voltage : Min. 8000V

PARAMETER :
Number of cores (mm2)
Nominal cross-sectional area (sq.mm) Construction, number/wire diameter (No./mm) Thickness of Insulation (mm) Thickness of Bedding (mm) Dianeter of steel wire (mm) Thickness of Sheath (mm) Approx.overall diameter (mm) Approx. Net Weight (kg/km)
5 1.5 7/0.53 0.6 0.8 0.9 1.4 14 456
7 1.5 7/0.53 0.6 0.8 0.9 1.4 14.9 467
9 1.5 7/0.53 0.6 0.8 1.25 1.5 18.1 693
12 1.5 7/0.53 0.6 0.8 1.25 1.5 19.1 784
19 1.5 7/0.53 0.6 0.8 1.25 1.6 21.8 1027
27 1.5 7/0.53 0.6 1 1.6 1.7 26.4 1512
37 1.5 7/0.53 0.6 1 1.6 1.8 30.1 1848
48 1.5 7/0.53 0.6 1 1.6 1.9 34.6 2246
5 2.5 7/0.67 0.7 0.8 0.9 1.5 15.9 516
7 2.5 7/0.67 0.7 0.8 1.25 1.5 17.6 707
9 2.5 7/0.67 0.7 0.8 1.25 1.6 20.6 887
12 2.5 7/0.67 0.7 0.8 1.25 1.6 21.9 1019
19 2.5 7/0.67 0.7 1 1.6 1.7 26.2 1550
27 2.5 7/0.67 0.7 1 1.6 1.8 30.4 1994
37 2.5 7/0.67 0.7 1.2 1.6 1.9 35 2508
48 2.5 7/0.67 0.7 1.2 2 2.1 41.2 3365
5 4 7/0.85 0.8 0.8 1.25 1.5 18.5 766
7 4 7/0.85 0.8 0.8 1.25 1.6 20 915
9 4 7/0.85 0.8 1 1.6 1.7 24.6 1329
12 4 7/0.85 0.8 1 1.6 1.7 26.2 1535
19 4 7/0.85 0.8 1 1.6 1.8 30 2052