{"id":11783,"date":"2025-10-27T09:14:54","date_gmt":"2025-10-27T01:14:54","guid":{"rendered":"https:\/\/totcables.com\/?p=11783"},"modified":"2025-10-27T09:15:43","modified_gmt":"2025-10-27T01:15:43","slug":"flame-retardant-and-fire-resistant-control-cable-za-zb-zc-series","status":"publish","type":"post","link":"https:\/\/totcables.com\/?p=11783","title":{"rendered":"Flame-Retardant and Fire-Resistant Control Cable (ZA, ZB, ZC Series)"},"content":{"rendered":"<p>{&#8220;main-title&#8221;:{&#8220;component&#8221;:&#8221;hc_title&#8221;,&#8221;id&#8221;:&#8221;main-title&#8221;,&#8221;title&#8221;:&#8221;&#8221;,&#8221;subtitle&#8221;:&#8221;The Flame-Retardant and Fire-Resistant Control Cable is designed for power transmission, instrumentation, and control systems under rated voltage 0.6\/1kV. It provides excellent flame retardancy, fire resistance, and stable electrical performance, suitable for use in environments requiring high safety and reliability, such as power plants, petrochemical industries, and industrial automation systems.&#8221;,&#8221;title_content&#8221;:{&#8220;component&#8221;:&#8221;hc_title_image&#8221;,&#8221;id&#8221;:&#8221;title-image&#8221;,&#8221;image&#8221;:&#8221;https:\/\/totcables.com\/wp-content\/uploads\/2025\/10\/kyjv-kyjvp-cable.webp|734|730|11784&#8243;,&#8221;full_screen&#8221;:false,&#8221;full_screen_height&#8221;:&#8221;&#8221;,&#8221;parallax&#8221;:false,&#8221;bleed&#8221;:&#8221;&#8221;,&#8221;ken_burn&#8221;:&#8221;&#8221;,&#8221;overlay&#8221;:&#8221;transparent-dark&#8221;,&#8221;breadcrumbs&#8221;:true,&#8221;white&#8221;:true,&#8221;position&#8221;:&#8221;&#8221;}},&#8221;section_5ZtkF&#8221;:{&#8220;component&#8221;:&#8221;hc_section&#8221;,&#8221;id&#8221;:&#8221;section_5ZtkF&#8221;,&#8221;section_width&#8221;:&#8221;&#8221;,&#8221;animation&#8221;:&#8221;&#8221;,&#8221;animation_time&#8221;:&#8221;&#8221;,&#8221;timeline_animation&#8221;:&#8221;&#8221;,&#8221;timeline_delay&#8221;:&#8221;&#8221;,&#8221;timeline_order&#8221;:&#8221;&#8221;,&#8221;vertical_row&#8221;:&#8221;&#8221;,&#8221;box_middle&#8221;:&#8221;&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;section_content&#8221;:[{&#8220;component&#8221;:&#8221;hc_column&#8221;,&#8221;id&#8221;:&#8221;column_vtfQF&#8221;,&#8221;column_width&#8221;:&#8221;col-md-12&#8243;,&#8221;animation&#8221;:&#8221;&#8221;,&#8221;animation_time&#8221;:&#8221;&#8221;,&#8221;timeline_animation&#8221;:&#8221;&#8221;,&#8221;timeline_delay&#8221;:&#8221;&#8221;,&#8221;timeline_order&#8221;:&#8221;&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;main_content&#8221;:[{&#8220;component&#8221;:&#8221;hc_wp_editor&#8221;,&#8221;id&#8221;:&#8221;Xhugf&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;editor_content&#8221;:&#8221;<\/p>\n<p data-start='339' data-end='772'>The <strong data-start='343' data-end='395'>Flame-Retardant and Fire-Resistant Control Cable<\/strong> is designed for <strong data-start='412' data-end='472'>power transmission, instrumentation, and control systems<\/strong> under rated voltage <strong data-start='493' data-end='504'>0.6\/1kV<\/strong>.<br data-start='505' data-end='508'>It provides <strong data-start='520' data-end='567'>excellent flame retardancy, fire resistance<\/strong>, and <strong data-start='573' data-end='606'>stable electrical performance<\/strong>, suitable for use in environments requiring <strong data-start='651' data-end='682'>high safety and reliability<\/strong>, such as <strong data-start='692' data-end='769'>power plants, petrochemical industries, and industrial automation systems<\/strong>.<\/p>\n<p>\\n<\/p>\n<p data-start='774' data-end='958'>Available in <strong data-start='787' data-end='803'>PVC-sheathed<\/strong> or <strong data-start='807' data-end='822'>PE-sheathed<\/strong> constructions, this cable family meets various <strong data-start='870' data-end='918'>flame-retardant classifications (ZA, ZB, ZC)<\/strong> and <strong data-start='923' data-end='945'>fire-resistant (N)<\/strong> standards.<\/p>\n<p>\\n\\n\\n<div id=\"attachment_11784\" style=\"width: 308px\" class=\"wp-caption aligncenter\"><img aria-describedby=\"caption-attachment-11784\" class='size-medium wp-image-11784' src='https:\/\/totcables.com\/wp-content\/uploads\/2025\/10\/kyjv-kyjvp-cable-298x300.webp' alt='kyjv kyjvp cable' width='298' height='300'><p id=\"caption-attachment-11784\" class=\"wp-caption-text\">kyjv kyjvp cable<\/p><\/div>\\n\\n<\/p>\n<hr data-start='960' data-end='963'>\\n\\n<\/p>\n<h2 data-start='965' data-end='1006'><strong data-start='968' data-end='1006'>Product Models and Structure Types<\/strong><\/h2>\n<p>\\n<\/p>\n<div class='mobile-scroll-table'>\\n<\/p>\n<div class='group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse' tabindex='-1'>\\n<\/p>\n<table class='w-fit min-w-(--thread-content-width)' data-start='1008' data-end='2494'>\\n<\/p>\n<thead data-start='1008' data-end='1125'>\\n<\/p>\n<tr data-start='1008' data-end='1125'>\\n<\/p>\n<th data-start='1008' data-end='1020' data-col-size='sm'><strong data-start='1010' data-end='1019'>Model<\/strong><\/th>\n<p>\\n<\/p>\n<th data-start='1020' data-end='1039' data-col-size='sm'><strong data-start='1022' data-end='1038'>Construction<\/strong><\/th>\n<p>\\n<\/p>\n<th data-start='1039' data-end='1060' data-col-size='sm'><strong data-start='1041' data-end='1059'>Shielding Type<\/strong><\/th>\n<p>\\n<\/p>\n<th data-start='1060' data-end='1077' data-col-size='sm'><strong data-start='1062' data-end='1076'>Armor Type<\/strong><\/th>\n<p>\\n<\/p>\n<th data-start='1077' data-end='1099' data-col-size='sm'><strong data-start='1079' data-end='1098'>Sheath Material<\/strong><\/th>\n<p>\\n<\/p>\n<th data-start='1099' data-end='1125' data-col-size='sm'><strong data-start='1101' data-end='1123'>Rated Voltage (kV)<\/strong><\/th>\n<p>\\n<\/tr>\n<p>\\n<\/thead>\n<p>\\n<\/p>\n<tbody data-start='1247' data-end='2494'>\\n<\/p>\n<tr data-start='1247' data-end='1306'>\\n<\/p>\n<td data-start='1247' data-end='1270' data-col-size='sm'>(ZA, ZB, ZC)(N)-KYJV<\/td>\n<p>\\n<\/p>\n<td data-start='1270' data-end='1283' data-col-size='sm'>PVC sheath<\/td>\n<p>\\n<\/p>\n<td data-start='1283' data-end='1287' data-col-size='sm'>\u2014<\/td>\n<p>\\n<\/p>\n<td data-start='1287' data-end='1291' data-col-size='sm'>\u2014<\/td>\n<p>\\n<\/p>\n<td data-start='1291' data-end='1297' data-col-size='sm'>PVC<\/td>\n<p>\\n<\/p>\n<td data-start='1297' data-end='1306' data-col-size='sm'>0.6\/1<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='1307' data-end='1380'>\\n<\/p>\n<td data-start='1307' data-end='1331' data-col-size='sm'>(ZA, ZB, ZC)(N)-KYJVP<\/td>\n<p>\\n<\/p>\n<td data-start='1331' data-end='1344' data-col-size='sm'>PVC sheath<\/td>\n<p>\\n<\/p>\n<td data-start='1344' data-end='1361' data-col-size='sm'>Braided shield<\/td>\n<p>\\n<\/p>\n<td data-start='1361' data-end='1365' data-col-size='sm'>\u2014<\/td>\n<p>\\n<\/p>\n<td data-start='1365' data-end='1371' data-col-size='sm'>PVC<\/td>\n<p>\\n<\/p>\n<td data-start='1371' data-end='1380' data-col-size='sm'>0.6\/1<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='1381' data-end='1459'>\\n<\/p>\n<td data-start='1381' data-end='1406' data-col-size='sm'>(ZA, ZB, ZC)(N)-KYJVP2<\/td>\n<p>\\n<\/p>\n<td data-start='1406' data-end='1419' data-col-size='sm'>PVC sheath<\/td>\n<p>\\n<\/p>\n<td data-start='1419' data-end='1440' data-col-size='sm'>Copper tape shield<\/td>\n<p>\\n<\/p>\n<td data-start='1440' data-end='1444' data-col-size='sm'>\u2014<\/td>\n<p>\\n<\/p>\n<td data-start='1444' data-end='1450' data-col-size='sm'>PVC<\/td>\n<p>\\n<\/p>\n<td data-start='1450' data-end='1459' data-col-size='sm'>0.6\/1<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='1460' data-end='1548'>\\n<\/p>\n<td data-start='1460' data-end='1485' data-col-size='sm'>(ZA, ZB, ZC)(N)-KYJVP3<\/td>\n<p>\\n<\/p>\n<td data-start='1485' data-end='1498' data-col-size='sm'>PVC sheath<\/td>\n<p>\\n<\/p>\n<td data-start='1498' data-end='1529' data-col-size='sm'>Aluminum\/plastic tape shield<\/td>\n<p>\\n<\/p>\n<td data-start='1529' data-end='1533' data-col-size='sm'>\u2014<\/td>\n<p>\\n<\/p>\n<td data-start='1533' data-end='1539' data-col-size='sm'>PVC<\/td>\n<p>\\n<\/p>\n<td data-start='1539' data-end='1548' data-col-size='sm'>0.6\/1<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='1549' data-end='1645'>\\n<\/p>\n<td data-start='1549' data-end='1574' data-col-size='sm'>(ZA, ZB, ZC)(N)-KYJVP4<\/td>\n<p>\\n<\/p>\n<td data-start='1574' data-end='1587' data-col-size='sm'>PVC sheath<\/td>\n<p>\\n<\/p>\n<td data-start='1587' data-end='1626' data-col-size='sm'>Copper\/plastic composite tape shield<\/td>\n<p>\\n<\/p>\n<td data-start='1626' data-end='1630' data-col-size='sm'>\u2014<\/td>\n<p>\\n<\/p>\n<td data-start='1630' data-end='1636' data-col-size='sm'>PVC<\/td>\n<p>\\n<\/p>\n<td data-start='1636' data-end='1645' data-col-size='sm'>0.6\/1<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='1646' data-end='1716'>\\n<\/p>\n<td data-start='1646' data-end='1671' data-col-size='sm'>(ZA, ZB, ZC)(N)-KYJV22<\/td>\n<p>\\n<\/p>\n<td data-start='1671' data-end='1684' data-col-size='sm'>PVC sheath<\/td>\n<p>\\n<\/p>\n<td data-start='1684' data-end='1688' data-col-size='sm'>\u2014<\/td>\n<p>\\n<\/p>\n<td data-start='1688' data-end='1701' data-col-size='sm'>Steel tape<\/td>\n<p>\\n<\/p>\n<td data-start='1701' data-end='1707' data-col-size='sm'>PVC<\/td>\n<p>\\n<\/p>\n<td data-start='1707' data-end='1716' data-col-size='sm'>0.6\/1<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='1717' data-end='1807'>\\n<\/p>\n<td data-start='1717' data-end='1745' data-col-size='sm'>(ZA, ZB, ZC)(N)-KYJVP2-22<\/td>\n<p>\\n<\/p>\n<td data-start='1745' data-end='1758' data-col-size='sm'>PVC sheath<\/td>\n<p>\\n<\/p>\n<td data-start='1758' data-end='1779' data-col-size='sm'>Copper tape shield<\/td>\n<p>\\n<\/p>\n<td data-start='1779' data-end='1792' data-col-size='sm'>Steel tape<\/td>\n<p>\\n<\/p>\n<td data-start='1792' data-end='1798' data-col-size='sm'>PVC<\/td>\n<p>\\n<\/p>\n<td data-start='1798' data-end='1807' data-col-size='sm'>0.6\/1<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='1808' data-end='1878'>\\n<\/p>\n<td data-start='1808' data-end='1833' data-col-size='sm'>(ZA, ZB, ZC)(N)-KYJV32<\/td>\n<p>\\n<\/p>\n<td data-start='1833' data-end='1846' data-col-size='sm'>PVC sheath<\/td>\n<p>\\n<\/p>\n<td data-start='1846' data-end='1850' data-col-size='sm'>\u2014<\/td>\n<p>\\n<\/p>\n<td data-start='1850' data-end='1863' data-col-size='sm'>Steel wire<\/td>\n<p>\\n<\/p>\n<td data-start='1863' data-end='1869' data-col-size='sm'>PVC<\/td>\n<p>\\n<\/p>\n<td data-start='1869' data-end='1878' data-col-size='sm'>0.6\/1<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='1879' data-end='1936'>\\n<\/p>\n<td data-start='1879' data-end='1902' data-col-size='sm'>(ZA, ZB, ZC)(N)-KYJY<\/td>\n<p>\\n<\/p>\n<td data-start='1902' data-end='1914' data-col-size='sm'>PE sheath<\/td>\n<p>\\n<\/p>\n<td data-start='1914' data-end='1918' data-col-size='sm'>\u2014<\/td>\n<p>\\n<\/p>\n<td data-start='1918' data-end='1922' data-col-size='sm'>\u2014<\/td>\n<p>\\n<\/p>\n<td data-start='1922' data-end='1927' data-col-size='sm'>PE<\/td>\n<p>\\n<\/p>\n<td data-start='1927' data-end='1936' data-col-size='sm'>0.6\/1<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='1937' data-end='2008'>\\n<\/p>\n<td data-start='1937' data-end='1961' data-col-size='sm'>(ZA, ZB, ZC)(N)-KYJYP<\/td>\n<p>\\n<\/p>\n<td data-start='1961' data-end='1973' data-col-size='sm'>PE sheath<\/td>\n<p>\\n<\/p>\n<td data-start='1973' data-end='1990' data-col-size='sm'>Braided shield<\/td>\n<p>\\n<\/p>\n<td data-start='1990' data-end='1994' data-col-size='sm'>\u2014<\/td>\n<p>\\n<\/p>\n<td data-start='1994' data-end='1999' data-col-size='sm'>PE<\/td>\n<p>\\n<\/p>\n<td data-start='1999' data-end='2008' data-col-size='sm'>0.6\/1<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='2009' data-end='2085'>\\n<\/p>\n<td data-start='2009' data-end='2034' data-col-size='sm'>(ZA, ZB, ZC)(N)-KYJYP2<\/td>\n<p>\\n<\/p>\n<td data-start='2034' data-end='2046' data-col-size='sm'>PE sheath<\/td>\n<p>\\n<\/p>\n<td data-start='2046' data-end='2067' data-col-size='sm'>Copper tape shield<\/td>\n<p>\\n<\/p>\n<td data-start='2067' data-end='2071' data-col-size='sm'>\u2014<\/td>\n<p>\\n<\/p>\n<td data-start='2071' data-end='2076' data-col-size='sm'>PE<\/td>\n<p>\\n<\/p>\n<td data-start='2076' data-end='2085' data-col-size='sm'>0.6\/1<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='2086' data-end='2172'>\\n<\/p>\n<td data-start='2086' data-end='2111' data-col-size='sm'>(ZA, ZB, ZC)(N)-KYJYP3<\/td>\n<p>\\n<\/p>\n<td data-start='2111' data-end='2123' data-col-size='sm'>PE sheath<\/td>\n<p>\\n<\/p>\n<td data-start='2123' data-end='2154' data-col-size='sm'>Aluminum\/plastic tape shield<\/td>\n<p>\\n<\/p>\n<td data-start='2154' data-end='2158' data-col-size='sm'>\u2014<\/td>\n<p>\\n<\/p>\n<td data-start='2158' data-end='2163' data-col-size='sm'>PE<\/td>\n<p>\\n<\/p>\n<td data-start='2163' data-end='2172' data-col-size='sm'>0.6\/1<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='2173' data-end='2267'>\\n<\/p>\n<td data-start='2173' data-end='2198' data-col-size='sm'>(ZA, ZB, ZC)(N)-KYJYP4<\/td>\n<p>\\n<\/p>\n<td data-start='2198' data-end='2210' data-col-size='sm'>PE sheath<\/td>\n<p>\\n<\/p>\n<td data-start='2210' data-end='2249' data-col-size='sm'>Copper\/plastic composite tape shield<\/td>\n<p>\\n<\/p>\n<td data-col-size='sm' data-start='2249' data-end='2253'>\u2014<\/td>\n<p>\\n<\/p>\n<td data-col-size='sm' data-start='2253' data-end='2258'>PE<\/td>\n<p>\\n<\/p>\n<td data-col-size='sm' data-start='2258' data-end='2267'>0.6\/1<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='2268' data-end='2336'>\\n<\/p>\n<td data-start='2268' data-end='2293' data-col-size='sm'>(ZA, ZB, ZC)(N)-KYJY23<\/td>\n<p>\\n<\/p>\n<td data-start='2293' data-end='2305' data-col-size='sm'>PE sheath<\/td>\n<p>\\n<\/p>\n<td data-start='2305' data-end='2309' data-col-size='sm'>\u2014<\/td>\n<p>\\n<\/p>\n<td data-start='2309' data-end='2322' data-col-size='sm'>Steel tape<\/td>\n<p>\\n<\/p>\n<td data-start='2322' data-end='2327' data-col-size='sm'>PE<\/td>\n<p>\\n<\/p>\n<td data-start='2327' data-end='2336' data-col-size='sm'>0.6\/1<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='2337' data-end='2425'>\\n<\/p>\n<td data-start='2337' data-end='2365' data-col-size='sm'>(ZA, ZB, ZC)(N)-KYJYP2-23<\/td>\n<p>\\n<\/p>\n<td data-start='2365' data-end='2377' data-col-size='sm'>PE sheath<\/td>\n<p>\\n<\/p>\n<td data-start='2377' data-end='2398' data-col-size='sm'>Copper tape shield<\/td>\n<p>\\n<\/p>\n<td data-start='2398' data-end='2411' data-col-size='sm'>Steel tape<\/td>\n<p>\\n<\/p>\n<td data-start='2411' data-end='2416' data-col-size='sm'>PE<\/td>\n<p>\\n<\/p>\n<td data-start='2416' data-end='2425' data-col-size='sm'>0.6\/1<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='2426' data-end='2494'>\\n<\/p>\n<td data-start='2426' data-end='2451' data-col-size='sm'>(ZA, ZB, ZC)(N)-KYJY33<\/td>\n<p>\\n<\/p>\n<td data-start='2451' data-end='2463' data-col-size='sm'>PE sheath<\/td>\n<p>\\n<\/p>\n<td data-start='2463' data-end='2467' data-col-size='sm'>\u2014<\/td>\n<p>\\n<\/p>\n<td data-start='2467' data-end='2480' data-col-size='sm'>Steel wire<\/td>\n<p>\\n<\/p>\n<td data-start='2480' data-end='2485' data-col-size='sm'>PE<\/td>\n<p>\\n<\/p>\n<td data-start='2485' data-end='2494' data-col-size='sm'>0.6\/1<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/tbody>\n<p>\\n<\/table>\n<p>\\n<\/p><\/div>\n<p>\\n<\/p><\/div>\n<p>\\n\\n<\/p>\n<hr data-start='2496' data-end='2499'>\\n\\n<\/p>\n<h2 data-start='2501' data-end='2520'><strong data-start='2504' data-end='2520'>Key Features<\/strong><\/h2>\n<p>\\n<\/p>\n<ul data-start='2522' data-end='3335'>\\n \\t<\/p>\n<li data-start='2522' data-end='2701'>\\n\n<p data-start='2524' data-end='2701'>\ud83d\udd25 <strong data-start='2527' data-end='2564'>Flame-Retardant &amp; Fire-Resistant:<\/strong> Available in ZA, ZB, and ZC classes for different safety levels; fire-resistant type ensures circuit integrity under flame conditions.<\/p>\n<p>\\n<\/li>\n<p>\\n \\t<\/p>\n<li data-start='2702' data-end='2849'>\\n\n<p data-start='2704' data-end='2849'>\u26a1 <strong data-start='2706' data-end='2743'>Excellent Electrical Performance:<\/strong> Cross-linked polyethylene (XLPE) insulation ensures superior dielectric strength and thermal stability.<\/p>\n<p>\\n<\/li>\n<p>\\n \\t<\/p>\n<li data-start='2850' data-end='2959'>\\n\n<p data-start='2852' data-end='2959'>\ud83e\uddef <strong data-start='2855' data-end='2882'>High Safety Protection:<\/strong> Low smoke and low toxicity reduce secondary hazards during fire incidents.<\/p>\n<p>\\n<\/li>\n<p>\\n \\t<\/p>\n<li data-start='2960' data-end='3086'>\\n\n<p data-start='2962' data-end='3086'>\ud83d\udcaa <strong data-start='2965' data-end='2991'>Mechanical Durability:<\/strong> Optional steel tape or steel wire armor enhances resistance to mechanical stress and impact.<\/p>\n<p>\\n<\/li>\n<p>\\n \\t<\/p>\n<li data-start='3087' data-end='3209'>\\n\n<p data-start='3089' data-end='3209'>\ud83e\udde9 <strong data-start='3092' data-end='3123'>Multiple Shielding Options:<\/strong> Braided, copper tape, or composite shields effectively prevent signal interference.<\/p>\n<p>\\n<\/li>\n<p>\\n \\t<\/p>\n<li data-start='3210' data-end='3335'>\\n\n<p data-start='3212' data-end='3335'>\ud83c\udf27\ufe0f <strong data-start='3216' data-end='3243'>Versatile Installation:<\/strong> Suitable for indoor laying, cable trenches, conduits, vertical shafts, and direct burial.<\/p>\n<p>\\n<\/li>\n<p>\\n<\/ul>\n<p>\\n\\n<\/p>\n<hr data-start='3337' data-end='3340'>\\n\\n<\/p>\n<h2 data-start='3342' data-end='3361'><strong data-start='3345' data-end='3361'>Applications<\/strong><\/h2>\n<p>\\n<\/p>\n<p data-start='3363' data-end='3523'>These cables are widely used in <strong data-start='3395' data-end='3428'>industrial automation systems<\/strong>, <strong data-start='3430' data-end='3457'>instrumentation control<\/strong>, <strong data-start='3459' data-end='3481'>power distribution<\/strong>, and <strong data-start='3487' data-end='3517'>safety monitoring circuits<\/strong> in:<\/p>\n<p>\\n\\n<\/p>\n<ul data-start='3524' data-end='3698'>\\n \\t<\/p>\n<li data-start='3524' data-end='3558'>\\n\n<p data-start='3526' data-end='3558'>Power stations and substations<\/p>\n<p>\\n<\/li>\n<p>\\n \\t<\/p>\n<li data-start='3559' data-end='3605'>\\n\n<p data-start='3561' data-end='3605'>Petrochemical and metallurgical industries<\/p>\n<p>\\n<\/li>\n<p>\\n \\t<\/p>\n<li data-start='3606' data-end='3657'>\\n\n<p data-start='3608' data-end='3657'>Building automation and fire protection systems<\/p>\n<p>\\n<\/li>\n<p>\\n \\t<\/p>\n<li data-start='3658' data-end='3698'>\\n\n<p data-start='3660' data-end='3698'>Transportation and mining facilities<\/p>\n<p>\\n<\/li>\n<p>\\n<\/ul>\n<p>\\n\\n<\/p>\n<hr data-start='3700' data-end='3703'>\\n\\n<\/p>\n<h2 data-start='3705' data-end='3726'><strong data-start='3708' data-end='3726'>Technical Data<\/strong><\/h2>\n<p>\\n<\/p>\n<div class='_tableContainer_1rjym_1'>\\n<\/p>\n<div class='group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse' tabindex='-1'>\\n<\/p>\n<table class='w-fit min-w-(--thread-content-width)' data-start='3728' data-end='4147'>\\n<\/p>\n<thead data-start='3728' data-end='3760'>\\n<\/p>\n<tr data-start='3728' data-end='3760'>\\n<\/p>\n<th data-start='3728' data-end='3739' data-col-size='sm'><strong data-start='3730' data-end='3738'>Item<\/strong><\/th>\n<p>\\n<\/p>\n<th data-start='3739' data-end='3760' data-col-size='md'><strong data-start='3741' data-end='3758'>Specification<\/strong><\/th>\n<p>\\n<\/tr>\n<p>\\n<\/thead>\n<p>\\n<\/p>\n<tbody data-start='3795' data-end='4147'>\\n<\/p>\n<tr data-start='3795' data-end='3823'>\\n<\/p>\n<td data-start='3795' data-end='3811' data-col-size='sm'>Rated Voltage<\/td>\n<p>\\n<\/p>\n<td data-start='3811' data-end='3823' data-col-size='md'>0.6\/1 kV<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='3824' data-end='3855'>\\n<\/p>\n<td data-start='3824' data-end='3836' data-col-size='sm'>Conductor<\/td>\n<p>\\n<\/p>\n<td data-start='3836' data-end='3855' data-col-size='md'>Annealed Copper<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='3856' data-end='3905'>\\n<\/p>\n<td data-start='3856' data-end='3869' data-col-size='sm'>Insulation<\/td>\n<p>\\n<\/p>\n<td data-start='3869' data-end='3905' data-col-size='md'>Cross-linked Polyethylene (XLPE)<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='3906' data-end='3928'>\\n<\/p>\n<td data-start='3906' data-end='3915' data-col-size='sm'>Sheath<\/td>\n<p>\\n<\/p>\n<td data-start='3915' data-end='3928' data-col-size='md'>PVC or PE<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='3929' data-end='3971'>\\n<\/p>\n<td data-start='3929' data-end='3953' data-col-size='sm'>Operating Temperature<\/td>\n<p>\\n<\/p>\n<td data-start='3953' data-end='3971' data-col-size='md'>-40\u00b0C to +90\u00b0C<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='3972' data-end='4010'>\\n<\/p>\n<td data-start='3972' data-end='3996' data-col-size='sm'>Flame Retardant Class<\/td>\n<p>\\n<\/p>\n<td data-start='3996' data-end='4010' data-col-size='md'>ZA, ZB, ZC<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='4011' data-end='4056'>\\n<\/p>\n<td data-start='4011' data-end='4029' data-col-size='sm'>Fire Resistance<\/td>\n<p>\\n<\/p>\n<td data-start='4029' data-end='4056' data-col-size='md'>IEC 60331 or GB\/T 19666<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/p>\n<tr data-start='4057' data-end='4147'>\\n<\/p>\n<td data-start='4057' data-end='4082' data-col-size='sm'>Minimum Bending Radius<\/td>\n<p>\\n<\/p>\n<td data-start='4082' data-end='4147' data-col-size='md'>6 \u00d7 Cable Diameter (unarmored), 12 \u00d7 Cable Diameter (armored)<\/td>\n<p>\\n<\/tr>\n<p>\\n<\/tbody>\n<p>\\n<\/table>\n<p>\\n<\/p><\/div>\n<p>\\n<\/p><\/div>\n<p>\\n\\n<\/p>\n<hr data-start='4149' data-end='4152'>\\n\\n<\/p>\n<h2 data-start='4154' data-end='4171'><strong data-start='4157' data-end='4171'>Advantages<\/strong><\/h2>\n<p>\\n<\/p>\n<ul data-start='4173' data-end='4451'>\\n \\t<\/p>\n<li data-start='4173' data-end='4249'>\\n\n<p data-start='4175' data-end='4249'>Complies with <strong data-start='4189' data-end='4202'>IEC 60502<\/strong>, <strong data-start='4204' data-end='4217'>GB\/T 9330<\/strong>, and <strong data-start='4223' data-end='4237'>GB\/T 19666<\/strong> standards<\/p>\n<p>\\n<\/li>\n<p>\\n \\t<\/p>\n<li data-start='4250' data-end='4335'>\\n\n<p data-start='4252' data-end='4335'>Ensures <strong data-start='4260' data-end='4282'>signal reliability<\/strong> and <strong data-start='4287' data-end='4308'>long service life<\/strong> in critical environments<\/p>\n<p>\\n<\/li>\n<p>\\n \\t<\/p>\n<li data-start='4336' data-end='4451'>\\n\n<p data-start='4338' data-end='4451'>Offers <strong data-start='4345' data-end='4385'>comprehensive structure combinations<\/strong> to meet shielding, armoring, and environmental protection needs<\/p>\n<p>\\n<\/li>\n<p>\\n<\/ul>\n<p>\\n\\n<\/p>\n<hr data-start='4453' data-end='4456'>\\n\\n<\/p>\n<h2 data-start='4458' data-end='4475'><strong data-start='4461' data-end='4475'>Conclusion<\/strong><\/h2>\n<p>\\n<\/p>\n<p data-start='4477' data-end='4742'>The <strong data-start='4481' data-end='4556'>(ZA, ZB, ZC)(N) Series Flame-Retardant and Fire-Resistant Control Cable<\/strong> is a <strong data-start='4562' data-end='4635'>premium choice for industrial automation, control, and safety systems<\/strong>, providing <strong data-start='4647' data-end='4714'>reliable performance, enhanced protection, and stable operation<\/strong> under extreme conditions.<\/p>\n<p>\\n<\/p>\n<p data-start='4744' data-end='4857'>\ud83d\udc49 <strong data-start='4747' data-end='4775'>Contact TOT Wire &amp; Cable<\/strong> for detailed specifications or to request a quotation tailored to your project.<\/p>\n<p>&#8220;}]}],&#8221;section_settings&#8221;:&#8221;&#8221;},&#8221;scripts&#8221;:{},&#8221;css&#8221;:{},&#8221;css_page&#8221;:&#8221; .mobile-scroll-table {\\n    overflow-x: auto;\\n    width: 100%;\\n  }\\n\\n  .mobile-scroll-table table {\\n    border-collapse: collapse;\\n    min-width: 800px;\\n    width: 100%;\\n    font-family: Arial, sans-serif;\\n  }\\n\\n  .mobile-scroll-table th,\\n  .mobile-scroll-table td {\\n    border: 1px solid #ccc;\\n    padding: 8px;\\n    text-align: center;\\n    white-space: nowrap;\\n  }\\n\\n  .mobile-scroll-table thead {\\n    background-color: #f2f2f2;\\n  }\\n\\n  .mobile-scroll-table .subheader {\\n    font-size: 13px;\\n    font-weight: normal;\\n    background-color: #fafafa;\\n  }\\n\\n  .mobile-scroll-table .header-row th {\\n    vertical-align: middle;\\n  }&#8221;,&#8221;template_setting&#8221;:{&#8220;settings&#8221;:{&#8220;id&#8221;:&#8221;settings&#8221;}},&#8221;template_setting_top&#8221;:{},&#8221;page_setting&#8221;:{&#8220;settings&#8221;:[&#8220;lock-mode-off&#8221;]},&#8221;post_type_setting&#8221;:{&#8220;settings&#8221;:{&#8220;image&#8221;:&#8221;https:\/\/totcables.com\/wp-content\/uploads\/2025\/10\/kyjv-kyjvp-cable.webp|734|730|11784&#8243;,&#8221;excerpt&#8221;:&#8221;The Flame-Retardant and Fire-Resistant Control Cable is designed for power transmission, instrumentation, and control systems under rated voltage 0.6\/1kV.\\nIt provides excellent flame retardancy, fire resistance, and stable electrical performance, suitable for use in environments requiring high safety and reliability, such as power plants, petrochemical industries, and industrial automation systems.&#8221;,&#8221;extra_1&#8243;:&#8221;&#8221;,&#8221;extra_2&#8243;:&#8221;&#8221;,&#8221;icon&#8221;:{&#8220;icon&#8221;:&#8221;&#8221;,&#8221;icon_style&#8221;:&#8221;&#8221;,&#8221;icon_image&#8221;:&#8221;&#8221;}}}}<\/p>\n","protected":false},"excerpt":{"rendered":"<p>{&#8220;main-title&#8221;:{&#8220;component&#8221;:&#8221;hc_title&#8221;,&#8221;id&#8221;:&#8221;main-title&#8221;,&#8221;title&#8221;:&#8221;&#8221;,&#8221;subtitle&#8221;:&#8221;The Flame-Retardant and Fire-Resistant Control Cable is designed for power transmission, instrumentation, and control systems under rated voltage 0.6\/1kV. It provides excellent flame retardancy, fire resistance, and stable electrical performance, suitable for use in environments requiring high safety and reliability, such as power plants, petrochemical industries, and industrial automation systems.&#8221;,&#8221;title_content&#8221;:{&#8220;component&#8221;:&#8221;hc_title_image&#8221;,&#8221;id&#8221;:&#8221;title-image&#8221;,&#8221;image&#8221;:&#8221;https:\/\/totcables.com\/wp-content\/uploads\/2025\/10\/kyjv-kyjvp-cable.webp|734|730|11784&#8243;,&#8221;full_screen&#8221;:false,&#8221;full_screen_height&#8221;:&#8221;&#8221;,&#8221;parallax&#8221;:false,&#8221;bleed&#8221;:&#8221;&#8221;,&#8221;ken_burn&#8221;:&#8221;&#8221;,&#8221;overlay&#8221;:&#8221;transparent-dark&#8221;,&#8221;breadcrumbs&#8221;:true,&#8221;white&#8221;:true,&#8221;position&#8221;:&#8221;&#8221;}},&#8221;section_5ZtkF&#8221;:{&#8220;component&#8221;:&#8221;hc_section&#8221;,&#8221;id&#8221;:&#8221;section_5ZtkF&#8221;,&#8221;section_width&#8221;:&#8221;&#8221;,&#8221;animation&#8221;:&#8221;&#8221;,&#8221;animation_time&#8221;:&#8221;&#8221;,&#8221;timeline_animation&#8221;:&#8221;&#8221;,&#8221;timeline_delay&#8221;:&#8221;&#8221;,&#8221;timeline_order&#8221;:&#8221;&#8221;,&#8221;vertical_row&#8221;:&#8221;&#8221;,&#8221;box_middle&#8221;:&#8221;&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;section_content&#8221;:[{&#8220;component&#8221;:&#8221;hc_column&#8221;,&#8221;id&#8221;:&#8221;column_vtfQF&#8221;,&#8221;column_width&#8221;:&#8221;col-md-12&#8243;,&#8221;animation&#8221;:&#8221;&#8221;,&#8221;animation_time&#8221;:&#8221;&#8221;,&#8221;timeline_animation&#8221;:&#8221;&#8221;,&#8221;timeline_delay&#8221;:&#8221;&#8221;,&#8221;timeline_order&#8221;:&#8221;&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;main_content&#8221;:[{&#8220;component&#8221;:&#8221;hc_wp_editor&#8221;,&#8221;id&#8221;:&#8221;Xhugf&#8221;,&#8221;css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_classes&#8221;:&#8221;&#8221;,&#8221;custom_css_styles&#8221;:&#8221;&#8221;,&#8221;editor_content&#8221;:&#8221; The Flame-Retardant and Fire-Resistant Control [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":11784,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1],"tags":[],"class_list":["post-11783","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-news"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v25.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Flame-Retardant and Fire-Resistant Control Cable (ZA, ZB, ZC Series)<\/title>\n<meta name=\"description\" content=\"The Flame-Retardant and Fire-Resistant Control Cable is designed for power transmission, instrumentation, and control systems under rated voltage 0.6\/1kV.It provides excellent flame retardancy, fire resistance, and stable electrical performance, suitable for use in environments requiring high safety and reliability, such as power plants, petrochemical industries, and industrial automation systems.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/totcables.com\/?p=11783\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Flame-Retardant and Fire-Resistant Control Cable (ZA, ZB, ZC Series)\" \/>\n<meta property=\"og:description\" content=\"The Flame-Retardant and Fire-Resistant Control Cable is designed for power transmission, instrumentation, and control systems under rated voltage 0.6\/1kV.It provides excellent flame retardancy, fire resistance, and stable electrical performance, suitable for use in environments requiring high safety and reliability, such as power plants, petrochemical industries, and industrial automation systems.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/totcables.com\/?p=11783\" \/>\n<meta property=\"og:site_name\" content=\"TOT Wire &amp; Cable\" \/>\n<meta property=\"article:published_time\" content=\"2025-10-27T01:14:54+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-10-27T01:15:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/totcables.com\/wp-content\/uploads\/2025\/10\/kyjv-kyjvp-cable.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"730\" \/>\n\t<meta property=\"og:image:height\" content=\"734\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"totcables\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"totcables\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/totcables.com\/?p=11783\",\"url\":\"https:\/\/totcables.com\/?p=11783\",\"name\":\"Flame-Retardant and Fire-Resistant Control Cable (ZA, ZB, ZC Series)\",\"isPartOf\":{\"@id\":\"https:\/\/totcables.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/totcables.com\/?p=11783#primaryimage\"},\"image\":{\"@id\":\"https:\/\/totcables.com\/?p=11783#primaryimage\"},\"thumbnailUrl\":\"https:\/\/totcables.com\/wp-content\/uploads\/2025\/10\/kyjv-kyjvp-cable.webp\",\"datePublished\":\"2025-10-27T01:14:54+00:00\",\"dateModified\":\"2025-10-27T01:15:43+00:00\",\"author\":{\"@id\":\"https:\/\/totcables.com\/#\/schema\/person\/66a1609cf8573817b344f580b01fc402\"},\"description\":\"The Flame-Retardant and Fire-Resistant Control Cable is designed for power transmission, instrumentation, and control systems under rated voltage 0.6\/1kV.It provides excellent flame retardancy, fire resistance, and stable electrical performance, suitable for use in environments requiring high safety and reliability, such as power plants, petrochemical industries, and industrial automation systems.\",\"breadcrumb\":{\"@id\":\"https:\/\/totcables.com\/?p=11783#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/totcables.com\/?p=11783\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/totcables.com\/?p=11783#primaryimage\",\"url\":\"https:\/\/totcables.com\/wp-content\/uploads\/2025\/10\/kyjv-kyjvp-cable.webp\",\"contentUrl\":\"https:\/\/totcables.com\/wp-content\/uploads\/2025\/10\/kyjv-kyjvp-cable.webp\",\"width\":730,\"height\":734,\"caption\":\"kyjv kyjvp cable\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/totcables.com\/?p=11783#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"\u9996\u9875\",\"item\":\"https:\/\/totcables.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Flame-Retardant and Fire-Resistant Control Cable (ZA, ZB, ZC Series)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/totcables.com\/#website\",\"url\":\"https:\/\/totcables.com\/\",\"name\":\"TOT Wire & Cable\",\"description\":\"Leading Wire and Cable Supplier &amp; Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/totcables.com\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/totcables.com\/#\/schema\/person\/66a1609cf8573817b344f580b01fc402\",\"name\":\"totcables\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/totcables.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/60f095fd74e776119ea1c6bf287b8a494a9337c31ecfddd4b710685b0eba600e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/60f095fd74e776119ea1c6bf287b8a494a9337c31ecfddd4b710685b0eba600e?s=96&d=mm&r=g\",\"caption\":\"totcables\"},\"sameAs\":[\"https:\/\/totcables.com\"],\"url\":\"https:\/\/totcables.com\/?author=1\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Flame-Retardant and Fire-Resistant Control Cable (ZA, ZB, ZC Series)","description":"The Flame-Retardant and Fire-Resistant Control Cable is designed for power transmission, instrumentation, and control systems under rated voltage 0.6\/1kV.It provides excellent flame retardancy, fire resistance, and stable electrical performance, suitable for use in environments requiring high safety and reliability, such as power plants, petrochemical industries, and industrial automation systems.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/totcables.com\/?p=11783","og_locale":"en_US","og_type":"article","og_title":"Flame-Retardant and Fire-Resistant Control Cable (ZA, ZB, ZC Series)","og_description":"The Flame-Retardant and Fire-Resistant Control Cable is designed for power transmission, instrumentation, and control systems under rated voltage 0.6\/1kV.It provides excellent flame retardancy, fire resistance, and stable electrical performance, suitable for use in environments requiring high safety and reliability, such as power plants, petrochemical industries, and industrial automation systems.","og_url":"https:\/\/totcables.com\/?p=11783","og_site_name":"TOT Wire &amp; Cable","article_published_time":"2025-10-27T01:14:54+00:00","article_modified_time":"2025-10-27T01:15:43+00:00","og_image":[{"width":730,"height":734,"url":"https:\/\/totcables.com\/wp-content\/uploads\/2025\/10\/kyjv-kyjvp-cable.webp","type":"image\/webp"}],"author":"totcables","twitter_card":"summary_large_image","twitter_misc":{"Written by":"totcables","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/totcables.com\/?p=11783","url":"https:\/\/totcables.com\/?p=11783","name":"Flame-Retardant and Fire-Resistant Control Cable (ZA, ZB, ZC Series)","isPartOf":{"@id":"https:\/\/totcables.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/totcables.com\/?p=11783#primaryimage"},"image":{"@id":"https:\/\/totcables.com\/?p=11783#primaryimage"},"thumbnailUrl":"https:\/\/totcables.com\/wp-content\/uploads\/2025\/10\/kyjv-kyjvp-cable.webp","datePublished":"2025-10-27T01:14:54+00:00","dateModified":"2025-10-27T01:15:43+00:00","author":{"@id":"https:\/\/totcables.com\/#\/schema\/person\/66a1609cf8573817b344f580b01fc402"},"description":"The Flame-Retardant and Fire-Resistant Control Cable is designed for power transmission, instrumentation, and control systems under rated voltage 0.6\/1kV.It provides excellent flame retardancy, fire resistance, and stable electrical performance, suitable for use in environments requiring high safety and reliability, such as power plants, petrochemical industries, and industrial automation systems.","breadcrumb":{"@id":"https:\/\/totcables.com\/?p=11783#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/totcables.com\/?p=11783"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/totcables.com\/?p=11783#primaryimage","url":"https:\/\/totcables.com\/wp-content\/uploads\/2025\/10\/kyjv-kyjvp-cable.webp","contentUrl":"https:\/\/totcables.com\/wp-content\/uploads\/2025\/10\/kyjv-kyjvp-cable.webp","width":730,"height":734,"caption":"kyjv kyjvp cable"},{"@type":"BreadcrumbList","@id":"https:\/\/totcables.com\/?p=11783#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"\u9996\u9875","item":"https:\/\/totcables.com\/"},{"@type":"ListItem","position":2,"name":"Flame-Retardant and Fire-Resistant Control Cable (ZA, ZB, ZC Series)"}]},{"@type":"WebSite","@id":"https:\/\/totcables.com\/#website","url":"https:\/\/totcables.com\/","name":"TOT Wire & Cable","description":"Leading Wire and Cable Supplier &amp; Manufacturer","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/totcables.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/totcables.com\/#\/schema\/person\/66a1609cf8573817b344f580b01fc402","name":"totcables","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/totcables.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/60f095fd74e776119ea1c6bf287b8a494a9337c31ecfddd4b710685b0eba600e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/60f095fd74e776119ea1c6bf287b8a494a9337c31ecfddd4b710685b0eba600e?s=96&d=mm&r=g","caption":"totcables"},"sameAs":["https:\/\/totcables.com"],"url":"https:\/\/totcables.com\/?author=1"}]}},"_links":{"self":[{"href":"https:\/\/totcables.com\/index.php?rest_route=\/wp\/v2\/posts\/11783","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/totcables.com\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/totcables.com\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/totcables.com\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/totcables.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=11783"}],"version-history":[{"count":2,"href":"https:\/\/totcables.com\/index.php?rest_route=\/wp\/v2\/posts\/11783\/revisions"}],"predecessor-version":[{"id":11786,"href":"https:\/\/totcables.com\/index.php?rest_route=\/wp\/v2\/posts\/11783\/revisions\/11786"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/totcables.com\/index.php?rest_route=\/wp\/v2\/media\/11784"}],"wp:attachment":[{"href":"https:\/\/totcables.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=11783"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/totcables.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=11783"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/totcables.com\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=11783"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}