NYY Cable

NYY cable is a type of power and control cable commonly used for fixed installations, particularly in energy supply systems. It is characterized by its PVC insulation and sheathing, making it suitable for indoor, tunnel, and pipe installations. NYY cables are known for their flexibility and resistance to moisture and dust.

  • Nyy Cable

NYY Cable


Power Cable 0.6/1kv with CU conductor PVC Insulated and PVC Jacket

  • Rated Voltage 0.6/1kV
  • Construction Cu / Pvc / Pvc
  • Standard IEC60502-1
  • Max. operating temperature +70°C
  • Max. curcuit temperature 160°C
  • Min. bending radius 12xD
  • Cable Type NYY Cable


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

NYY cable is a type of power and control cable commonly used for fixed installations, particularly in energy supply systemsIt is characterized by its PVC insulation and sheathing, making it suitable for indoor, tunnel, and pipe installations. NYY cables are known for their flexibility and resistance to moisture and dust. 

NYY Cable Application

NYY Cable used as lighting and power distribution cable, installed in areas where severe mechanical stress is avoided. Can be laid in doors,out-doors,buried or in cable tranches.

Construction

Construction of NYY Cable

Construction of NYY Cable

TECHNICAL FEATURES :

NYY Cable Technical Features
0,6/1 kV PVC insulated, multi-core cables with copper conductor.

ConstructionCu / Pvc / Pvc / Pvc
StandardIEC60502-1
Application AreaUsed as lighting and power distribution cable, installed in areas where severe mechanical stress is avoided. Can be laid in doors,out-doors,buried or in cable tranches.
Max. operating temperature+70°C
Max. curcuit temperature160°C
Min. bending radius12xD

PARAMETER :

NYY CABLE SPECIFICATION

0.6/1kV-1 core copper conductor PVC insulated PVC sheathed power cable
0.6/1kV-1 core copper conductor PVC insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of InsulationThickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
1X101.01.48.61591.835584
1X161.01.49.62251.1574110
1X251.21.411.23210.72795135
1X351.21.412.24180.524115165
1X501.41.413.65520.387140195
1X701.41.415.57540.268180240
1X951.61.517.710200.193220290
1X1201.61.519.112680.153255325
1X1501.81.62115840.124295370
1X1852.01.723.319420.0991340420
1X2402.21.826.225140.0754405485
1x3002.41.92931270.0601470550
1x4002.6232.340540.047550630
1x5002.82.136.251640.0366635715
1X6302.82.24064310.0283735820
0.6/1kV-2 core copper conductor PVC insulated PVC sheathed power cable
0.6/1kV-2 core copper conductor PVC insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of InsulationThickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
2X2.50.81.810.91497.4125-
2X411.812.72284.6133-
2X611.813.72783.0842-
2X1011.816.23801.835884
2X1611.818.45301.1576110
2X251.21.821.77540.72798140
2X351.21.823.09620.524120175
2X501.41.826.412740.387145205
2X701.41.929.717240.268185255
2X951.62.034.223330.193230305
2X1201.62.137.228860.153265350
2X1501.82.241.236010.124305390
2X18522.445.544150.0991350440
0.6/1kV-3 core copper conductor PVC insulated PVC sheathed power cable
0.6/1kV-3 core copper conductor PVC insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of InsulationThickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
3X2.50.81.811.41847.4121-
3X41.01.813.32634.6128-
3X61.01.814.53373.0836-
3X101.01.817.14951.834972
3X161.01.819.57031.156694
3X251.21.823.110100.72784120
3X351.21.824.513110.524100145
3X501.41.828.217460.387125175
3X701.41.931.823900.268160210
3X951.62.136.632470.193195255
3X1201.62.239.940340.153235295
3X1501.82.344.250440.124260330
3X18522.548.861910.0991305370
3X2402.22.755.080310.0754360425
3X3002.42.860.899890.0601410480
0.6/1kV-4 core copper conductor PVC insulated PVC sheathed power cable
0.6/1kV-4 core copper conductor PVC insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of InsulationThickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
4X2.50.81.812.32237.4121-
4X411.814.43254.6128-
4X611.815.74213.0836-
4X1011.818.76241.834972
4X1611.821.38951.156694
4X251.21.825.312930.72784120
4X351.21.826.916900.524100145
4X501.41.931.222710.387125175
4X701.42.035.331170.268160210
4X951.62.240.742410.193195255
4X1201.62.344.352760.153235295
4X1501.82.549.266030.124260330
4X18522.654.481110.0991305370
4X2402.22.961.3105310.0754360425
4X3002.43.167.8131090.0601410480
0.6/1kV-5 core copper conductor PVC insulated PVC sheathed power cable
0.6/1kV-5 core copper conductor PVC insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of InsulationThickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
5X2.50.81.813.32747.4121-
5X411.815.63974.6128-
5X611.817.15083.0836-
5X1011.820.47681.834972
5X1611.823.410951.156694
5X251.21.827.915890.72784120
5X351.21.929.720910.524100145
5X501.42.034.628180.387125175
5X701.42.239.238730.268160210
5X951.62.345.252750.193195255
5X1201.62.549.365670.153235295
5X1501.82.654.882220.124260330
5X18522.860.5101040.0991305370
5X2402.23.168.3131240.0754360425
5X3002.43.375.5163420.0601410480
0.6/1kV-3+1 core copper conductor PVC insulated PVC sheathed power cable
0.6/1kV-3+1 core copper conductor PVC insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of InsulationThickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
3*4+1*2.51.0/0.81.813.95004.61/7.4128-
3*6+1*41.0/1.01.815.43973.08/4.6136-
3*10+1*61.0/1.01.818.05731.83/3.084972
3*16+1*101.0/1.020.71.88271.15/1.836694
3*25+1*161.2/1.01.824.412190.727/1.1584120
3*35+1*161.2/1.01.825.615020.524/1.15100145
3*50+1*251.4/1.21.929.820420.387/0.727125175
3*70+1*351.4/1.22.033.327840.268/0.524160210
3*95+1*501.6/1.42.138.437610.193/0.387195255
3*120+1*701.6/1.42.242.247480.153/0.268235295
3*150+1*701.8/1.42.445.956380.124/0.268260330
3*185+1*952.0/1.62.551.071660.0991/0.193305370
3*240+1*1202.2/1.62.757.291930.0754/0.153360425
3*300+1*1502.4/1.82.963.3114520.0601/0.124410480
0.6/1kV-4+1 core copper conductor PVC insulated PVC sheathed power cable
0.6/1kV-4+1 core copper conductor PVC insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of InsulationThickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
4*4+1*2.51.0/0.81.815.23654.61/7.4128-
4*6+1*41.0/1.01.816.84843.08/4.6136-
4*10+1*61.0/1.01.819.77071.83/3.084972
4*16+1*101.0/1.01.822.810261.15/1.836694
4*25+1*161.2/1.01.827.015050.727/1.1584120
4*35+1*161.2/1.01.828.418830.524/1.15100145
4*50+1*251.4/1.22.033.225870.387/0.727125175
4*70+1*351.4/1.22.137.335250.268/0.524160210
4*95+1*501.6/1.42.343.148480.193/0.387195255
4*120+1*701.6/1.42.447.360630.153/0.268235295
4*150+1*701.8/1.42.551.672240.124/0.268260330
4*185+1*952.0/1.62.757.591260.0991/0.193305370
4*240+1*1202.2/1.63.064.5117780.0754/0.153360425
4*300+1*1502.4/1.83.271.4146450.0601/0.124410480
0.6/1kV-3+2 core copper conductor PVC insulated PVC sheathed power cable
0.6/1kV-3+2 core copper conductor PVC insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of InsulationThickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
3*4+2*2.51.0/0.81.814.73414.61/7.4128-
3*6+2*41.0/1.01.816.54613.08/4.6136-
3*10+2*61.0/1.01.819.06571.83/3.084972
3*16+2*101.0/1.01.822.29591.15/1.836694
3*25+2*161.2/1.01.826.013990.727/1.1584120
3*35+2*161.2/1.01.827.016800.524/1.15100145
3*50+2*251.4/1.21.932.023310.387/0.727125175
3*70+2*351.4/1.22.035.431620.268/0.524160210
3*95+2*501.6/1.42.241.043180.193/0.387195255
3*120+2*701.6/1.42.345.354980.153/0.268235295
3*150+2*701.8/1.42.448.563790.124/0.268260330
3*185+2*952.0/1.62.654.481680.0991/0.193305370
3*240+2*1202.2/1.62.860.7104620.0754/0.153360425
3*300+2*1502.4/1.83.067.2129560.0601/0.124410480