N2XBH Cable

The N2XBH cable is a 0.6/1 kV power cable with copper conductors, XLPE insulation, steel tape armor for mechanical protection, and HFFR (Halogen-Free Flame Retardant) sheathing. It is designed for safe and reliable power distribution in industrial and building installations, offering durability, flexibility, and enhanced fire safety.

  • slide

N2XBH Cable


Power cable 0,6/1 kV with Cu conductors, XLPE insulated Steel Tape Armoured HFFR sheathed

  • Rated Voltage 0.6/1kV
  • Conductor Material Plain annealed copper
  • Insulation Material XLPE
  • Sheath HFFR
  • Package Export wooden drum


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

N2XBH Cable Application

0.6/1 kV XLPE insulated, halogen-free, flame retardant, galvanized steel tape armoured power cables are used in generally underground where high tensile stresses and mechanical protection are needed during the operation. These cables are used in intelligent or semi-intelligent buildings which has high dense human population like hospitals, cinemas, theatres, schools, shopping centers.

N2XBH Cable Standard

DIN VDE 0276-604, TS HD 604.S1, IS 1516.1, IEC 60502-1
Flame retardant according to IEC 60332-3-24 Cat. C Low Smoke Zero Halogen according to IEC/EN 60754-1/2, IEC/ EN 61034-1/2

CONSTRUCTION :

Conductor: Class 2 Stranded copper
Insulation : XLPE (Cross-Linked Polyethylene)
Filler : HFFR (Halogen free flame retardant)
Armour: Double galvanized steel tape
Outer Sheath : HFFR (Halogen free flame retardant)

Core Identification
2 core: Blue Brown
3 core: Brown Black Grey
4 core: Blue Brown Black Grey
5 core: Blue Brown Black Grey Black
Sheath Colour : Black Green

TECHNICAL :

Operating Voltage:0.6/1 kV
Test Voltage:3.5 kV
Max. Operating Temperature:90 °C
Flame Retardancy:IEC/EN 60332-3-24
Smoke Density:IEC/EN 61034-1+2
Corrosive Gases Measurement:IEC/EN 60754-2
Amount of Halogen Acid Gas:IEC/EN 60754-1
Min. Bending Radius:Single Core: 15 x Cable Diameter, Multicore: 12 x Cable Diameter

PARAMETER :

NO. OF CORES NOMINAL CROSS SECTIONAL AREA NOMINAL DIAMETER OF CONDUCTOR NOMINAL THICKNESS OF INSULATION NOMINAL THICKNESS OF OUTER SHEATH NOMINAL OVERALL DIAMETER NOMINAL WEIGHT
mm² mm mm mm mm kg/km
2 2.5 1.76 0.7 1.24 13 276
2 4 2.21 0.7 1.24 14 326
2 6 2.71 0.7 1.24 15 384
2 10 3.85 0.7 1.24 17 498
2 16 4.8 0.7 1.24 19 649
2 25 5.85 0.9 1.24 22 882
2 35 6.9 0.9 1.32 24 1113
2 50 8.1 1 1.4 27 1421
2 70 9.7 1.1 1.48 31 1899
2 95 11.4 1.1 1.64 35 2482
3 1.5 1.36 0.7 1.24 12 265
3 2.5 1.76 0.7 1.24 14 342
3 4 2.21 0.7 1.24 15 417
3 6 2.71 0.7 1.24 16 501
3 10 3.85 0.7 1.24 19 704
3 16 4.8 0.7 1.24 21 938
3 25 5.85 0.9 1.24 24 1315
3 35 6.9 0.9 1.32 26 1682
3 50 8.1 1 1.4 29 2176
3 70 9.7 1.1 1.48 34 2949
3 95 11.4 1.1 1.64 38 4004
3 120 12.65 1.2 1.72 42 5215
3 150 14.4 1.4 1.88 47 6413
3 185 15.75 1.6 2.04 51 7719
3 240 18.2 1.7 2.2 58 9961
3 16+10 4.8 0.7 1.24 21 1073
3 25+16 5.85 0.9 1.24 25 1511
3 35+16 6.9 0.9 1.32 27 1861
3 50+25 8.1 1 1.4 30 2377
3 70+35 9.7 1.1 1.56 35 3235
3 95+70 11.4 1.1 1.64 39 4634
3 120+70 12.65 1.2 1.8 44 5813
3 150+70 14.4 1.4 1.88 48 6888
3 185+95 15.75 1.6 2.04 52 8412
3 240+120 18.2 1.7 2.2 59 10679
4 1.5 1.36 0.7 1.24 13 309
4 2.5 1.76 0.7 1.24 14 369
4 4 2.21 0.7 1.24 16 469
4 6 2.71 0.7 1.24 17 577
4 10 3.85 0.7 1.24 20 821
4 16 4.8 0.7 1.24 22 1113
4 25 5.85 0.9 1.32 25 1593
4 35 6.9 0.9 1.4 28 2060
4 50 8.1 1 1.48 32 2637
4 70 9.7 1.1 1.56 36 3611
4 95 11.4 1.1 1.72 41 5355
4 120 12.65 1.2 1.88 46 6590
4 150 14.4 1.4 1.96 51 8096
4 185 15.75 1.6 2.12 56 9795
4 240 18.2 1.7 2.36 63 12585
5 1.5 1.36 0.7 1.24 14 368
5 2.5 1.76 0.7 1.24 15 432
5 4 2.21 0.7 1.24 17 543
5 6 2.71 0.7 1.24 18 679
5 10 3.85 0.7 1.24 21 981
5 16 4.8 0.7 1.24 24 1351
5 25 5.85 0.9 1.32 28 1960
5 35 6.9 0.9 1.4 31 2539
5 50 8.1 1 1.48 35 3333
5 70 9.7 1 1.48 39 4507
5 95 11.4 1.1 1.56 44 6038