Copper Conductor Quadruplex Service Drop Cable 600V

The Copper Conductor Quadruplex Service Drop Cable 600V is designed for overhead electrical service connections from utility poles to residential or commercial buildings. Constructed with high-quality copper conductors, this cable offers excellent conductivity and durability to withstand outdoor environmental conditions. Its quadruplex configuration includes two insulated phase conductors, one insulated neutral, and a bare or insulated ground wire, providing a reliable and safe power delivery. Rated for 600 volts, it is suitable for overhead service drops, ensuring efficient and secure electrical supply. The weather-resistant insulation and robust construction make it ideal for outdoor installation, meeting industry standards for safety and performance.

  • slide

Copper Conductor Quadruplex Service Drop Cable 600V


NS75/NS90 Quadruplex Unjacketed Overhead Neutral Supported Cable

  • Conductor Stranded compressed soft copper
  • Insulation Thermoplastic Polyethylene or Cross-linked Polyethylene
  • Voltage 600V
  • Number of cores Quadruplex
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

Copper Quadruplex Service Drop Cable Application

Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. Also suitable for installations for street lighting, security lights, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75 ºC for polyethylene insulated conductors and 90 ºC for cross-linked polyethylene (XLP) insulated conductors.

Copper Quadruplex Service Drop Cable Specifications

Meets or exceeds the following ASTM specifications:
B-1 Hard-Drawn Copper Wire.
B-3 Soft or Annealed Copper Wire.
B-8 Concentric-Lay-Stranded Copper Conductors, Hard, Medium-Hard, or Soft.
Meets or exceeds all applicable requirements of ANSI/ICEA S-76-474 for polyethylene and cross-linked polyethylene insulated conductors.

Copper Quadruplex Overhead Service Drop Cable Wire Construction

Conductors are concentrically stranded compressed soft copper insulated with either cross-linked polyethylene, or conventional polyethylene.
Neutral messengers are either solid or concentrically stranded bare hard-drawn copper.

Notes:
Code words for XLP insulated products are formed by adding ''XLP'' to the conventional polyethylene code words above (e.g.-Theta/XLP).
Ampacity figures for black insulation only. Based on conductor temperature of 75 ºC for polyethylene insulated conductors, 90 ºC for XLP insulated conductors, ambient temperature of 40 ºC 2 ft./sec. wind in sun.

Copper Quadruplex Overhead Service Drop Cable Wire Technical Data

Rated voltage

kV

0.6/1

Test voltage

Veff kV/Hz

4/50

Laying temperature

°C

min. -5

Operating temperature

°C

-30 ~ +90

Conductor temperature

°C

max. +90

Short-circuit temperature

°C/s

max. +250 /5

Bending radius (min.)

mm

20 × Ø of cable

Quadruplex Cable – Copper Service Drop Cable Wire Parameter
Code Word Copper Phase Conductor Bare Copper Neutral Messenger Weight Per 1000 Ft. (lbs.) Allowable Ampacities+
Size (AWG) Stranding Insulation Thickness (mils.) Size (AWG) Stranding Rated Strength (lbs.) Polyethylene XLP Polyethylene XLP
Atlanta 6 7 45 6 Solid 1280 368 374 75 95
Tallahassee 6 7 45 6 7 1228 369 376 75 95
Richmond 4 7 45 4 7 1938 573 581 100 125
Baton Rouge 4 7 45 4 Solid 1970 570 578 100 125
Jackson 2 7 45 2 Solid 3003 889 889 135 170
Seattle 2 7 45 2 7 3050 893 893 135 170
Nashville 1/0 19 60 1/0 7 4752 1420 1457 180 230
Lincoln 2/0 19 60 2/0 7 5926 1773 1773 205 265
Raleigh 3/0 19 60 3/0 7 7366 2220 2220 235 305
Denver 4/0 19 60 4/0 7 9154 2781 2803 270 350