6-6-6 Patella Aluminum Conductor Triplex Overhead Service Drop Cable Wire

The 6-6-6 Patella Aluminum Conductor Triplex Overhead Service Drop Cable Wire is crafted for dependable overhead electrical connections. Featuring three aluminum conductors arranged in a triplex configuration, each with a 6 AWG size, this cable provides efficient and safe power transmission from utility poles to residential or commercial establishments. Constructed with high-quality aluminum using the Patella technique, it offers excellent flexibility, strength, and resistance to environmental factors such as moisture, corrosion, and weathering. Designed for outdoor overhead use, this durable cable ensures long-lasting performance and reliable electrical service in various outdoor conditions.

  • slide

6-6-6 Patella Aluminum Conductor Triplex Overhead Service Drop Cable Wire


Overhead Neutral-supported Multiplex Conductor:Patella

  • Code Word Patella
  • Size AWG (Phase Conductors) 6
  • Voltage 600V
  • Number of cores Triplex
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

6-6-6 Patella Aluminum Conductor Triplex Overhead Service Drop Cable Wire Application

6-6-6 Patella Triplex aluminum wire has three conductors, with one of them being for neutral path, and two electrodes. Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.

6-6-6 Patella Aluminum Conductor Triplex Overhead Service Drop Cable Wire Standard

ASTM B-230 Aluminum Wire 1350-H19 for Electrical Purposes.
ASTM B-231 Aluminum Conductors, Concentric-Lay-Stranded
ASTM B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
ASTM B-309 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
ASTM B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474.

6-6-6 Patella Aluminum Conductor Triplex Overhead Service Drop Cable Wire Construction

 Triplex Overhead Service Drop Cable Wire Construction

Triplex Overhead Service Drop Cable Wire Construction

Phase Conductor Strand or Compressed 1350-H19 Series Aluminum Conductor.
Neutral(Messenger)Conductor Bare AAC messenger.
Insulation Black Cross Linked Polyethylene (XLP) Insulation.

6-6-6 Patella Aluminum Conductor Triplex Overhead Service Drop Cable Wire Technical Data

Rated voltage V 600
Test voltage Veff kV/Hz 4/50
Laying temperature °C min. -5
Operating temperature °C -30 ~ +90
Conductor temperature °C max. +90
Short-circuit temperature °C/s max. +250 /5
Bending radius (min.) mm 20 × Ø of cable
6-6-6 Patella Aluminum Conductor Triplex Overhead Service Drop Cable Wire Parameter
Code Name Patella
Phase Conductor Size/AWG 6
Phase Conductor Stranding 7/w
Phase Conductor Insulation Thickness 45 mls
Bare Neutral Messenger Size/AWG 6
Bare Neutral Messenger Stranding 7
Bare Neutral Messenger Breaking Strength 563 Lbs
Weight Per (lb/1000 ft) XLP 109.1 Lbs
Weight (lb/1000 ft) Poly 101.6 Lbs
Ampacity XLP 85 Amps
Ampacity Poly 70 Amps