3 Core Armoured Cable Copper Cu/XLPE/PVC/SWA/PVC BS5467 0.6/1kV

The 3-core armoured cable with Copper Cu/XLPE/PVC/SWA/PVC construction is a high-quality low voltage power cable rated at 0.6/1kV. It features stranded copper conductors for excellent conductivity, XLPE insulation for enhanced thermal and electrical performance, and PVC outer and inner sheathing for durability and environmental protection. The steel wire armour (SWA) provides robust mechanical protection, making this cable suitable for underground, outdoor, and industrial applications where safety and reliability are essential. Designed in accordance with BS5467 standards, it is ideal for distributing electrical power in demanding environments.

  • slide

3 Core Armoured Cable Copper Cu/XLPE/PVC/SWA/PVC BS5467 0.6/1kV


3 Core Armoured Cable Copper XLPE PVC SWA 0.6/1kV

  • Rated Voltage 600/1000 Volts
  • Conductor Material soft annealed copper
  • Insulation Cross Linked Poly Ethylene (XLPE)
  • Armour Steel Wire Armoured
  • Oversheath PVC


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

3 Core SWA Armoured Cable Application

These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage. The lead sheath brings an enhanced resistance to aromatic hydrocarbons.

3 Core SWA Armoured Cable Standard

BS 5467 IEC 60502-1.

TECHNICAL DATA :

3 Core SWA Armoured Cable Technical Data

STANDARD IEC 60502-1, BS 5467 and BS 6346
APPLICATION Distribution networks, Industrial use
CHEMICAL PERFORMANCE Chemical & Oil resistance: Good
MECHANICAL PERFORMANCE Minimum bending raduis: x15cable diameter (unarmoured)
Minimum bending raduis: x20 cable diameter (armoured)
FIRE PERFORMANCE Flame non-propagation base on IEC 60332-1
Reduced emission of Halogens chlorine<15%
TERMINAL PERFORMANCE Maximum service temperature: 90°C
Maximum short-circuit temperature: 150°C(max. 5s)
Minimum service temperature: -40°C
3 Core SWA Armoured Cable Parameter
No. of Core x Nominal Section( mm2 ) Insulation Thickness( mm ) Approx. Diameter( mm ) SWA Diamete( mm ) Approx. Overall Diameter( mm ) Calculated Cable Weight( kg/km ) Max. DC Resistance at 20(Ω/ km ) Clipped On perf. cable Direct ( A ) tray or free air( A ) Voltage Drop( mV/A/m )
3 x 1.5 0.7 8 0.8 13.2 344 12.1 23 25 27
3 x 2.5 0.7 8.9 0.8 14.1 400 7.41 31 33 16
3 x 4 0.7 10 0.8 15.2 476 4.61 42 44 10
3 x 6 0.7 11.1 0.8 17.2 720 3.08 53 56 6.8
3 x 10 0.7 12.8 1.25 18.9 905 1.83 73 78 4
3 x 16 0.7 14.7 1.25 20.8 1152 1.15 94 99 2.5
3 x 25 0.9 18 1.6 24.8 1735 0.73 124 131 1.65
3 x 35 0.9 20.4 1.6 27.2 2137 0.52 154 162 1.15
3 x 50 1 23.6 1.6 30.7 2740 0.39 187 197 0.87
3 x 70 1.1 27.5 2 35.7 3849 0.27 238 251 0.6
3 x 95 1.1 30.9 2 39.4 4776 0.19 289 304 0.45
3 x 120 1.2 34.4 2 43.1 5719 0.15 335 353 0.37
3 x 150 1.4 38.7 2.5 48.7 7443 0.12 386 406 0.3
3 x 185 1.6 42.8 2.5 53.1 8785 0.1 441 463 0.26
3 x 240 1.7 47.9 2.5 58.7 10773 0.08 520 546 0.21
3 x 300 1.8 53.1 2.5 64.2 12915 0.06 599 628 0.19
3 x 400 2 60.7 3.15 73.6 17504 0.05 673 728 0.17