XLPE Insulated 3×300+1x150mm2 3+1 Cores Copper Cable

This is an unarmoured copper power cable with XLPE insulation and PVC sheathing, comprising three cores of 300mm² and one core of 150mm² (3+1 configuration). Rated for 0.6/1kV, it is designed for low-voltage power distribution in industrial, commercial, and infrastructure projects. The XLPE insulation provides excellent thermal, chemical, and mechanical properties, while the PVC sheath offers environmental protection. This cable is suitable for indoor and outdoor installations where mechanical protection is not required, ensuring reliable and efficient electrical transmission.

  • Xlpe Insulated 3x3001x150mm2 31 Cores Copper Cable

XLPE Insulated 3x300+1x150mm2 3+1 Cores Copper Cable


XLPE Insulated, PVC Sheathed Unarmoured 3x300+1x150mm2 3+1 Cores Copper Cable, 0.6/1kV

  • Number of cores 3+1
  • Cross section area 3x300+1x150mm2
  • Conductor Copper
  • Rated Voltage 600/1000 Volts
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

XLPE 3x300+1x150mm2 Copper Cable Application

The structure of 3 cores+1 earth cable wire is designed for application where the earth wires are required according to customer requirements. This 3 core and earth cable/wire ais often referred 3 cores +1 cables XLPE insulated with voltage 0.6/1000v or IEC 60502 3 core and earth cable.

3 core plus earth cable has three conductors which are coded three different colors plus the earth. One of the main applications for this three core and earth lighting cable is when two way lighting is required, it provides the additional conductor between two switches operating the same light fitting.

XLPE 3x300+1x150mm2 Copper Cable Standard

IEC 60228 Conductors
IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV) up to 35kV(Um=40.5kV) - Part 1: Cables for rated voltages of 1 kV(Um=1.2kV) and 3 kV(Um=3.6kV)

CONSTRUCTION :

XLPE 3x300+1x150mm2 Cable Construction
1. Conductor: Plain annealed copper, Class 2: stranded conductor
2. Insulation: Cross-linked polyethylene XLPE
3. Filler: Non-hygroscopic material
4. Binder tape: Non-hygroscopic material
5. Outer sheath: Polyvinyl chloride PVC

XLPE 3+1 Cores Cable Construction

XLPE 3+1 Cores Cable Construction

PARAMETER :

XLPE 3x300+1x150mm2 Copper Cable Parameter

Cable Type: CU/XLPE/PVC
Operating voltage, U0 / U (V): 600/1000
Number of cores: 3+1
Phase Conductor Nominal Area (mm2): 300
Earth Conductor Nominal Area (mm2):

150
Phase Conductor Stranding: 60
Earth Conductor Stranding:

30
Phase Conductor Insulation Thickness (mm): 1.8
Earth Conductor Insulation Thickness (mm):

1.4
Sheath Thickness (mm): 2.9
Cable Overall Diameter (O.D.) (mm): 57
Cable Weight Per 1000 Meters (kg): 10000
Phase Conductor Resistance DC 20°C Per 1000 Meters (Ω): 0.0601
Earth Conductor Resistance DC 20°C Per 1000 Meters (Ω):

0.124
Allowable Ampacity in Air (Amps): 555
Allowable Ampacity  in Ground (Amps): 565
Test Voltage:
3.5kV for 5 minutes
Operating temperature (°C) : -15 to +90

Final short circuit temperature (°C):

250