This is a 4-core copper cable with a cross-sectional area of 300mm² per core, insulated with XLPE and protected with a PVC sheath. Rated at 0.6/1kV, it is designed for high-capacity medium-voltage power distribution. The XLPE insulation provides excellent thermal endurance, electrical stability, and long-term reliability, suitable for heavy-duty industrial and infrastructure applications. The PVC sheath offers additional environmental and mechanical protection, guarding against moisture, chemicals, and physical damage. As an unarmoured cable, it is typically installed in conduit, cable trays, or trunking systems, making it suitable for reliable, high-current power transmission where mechanical protection is not required.

  • slide

XLPE Insulated 300mm2 4 Cores Copper Cable 4x300mm2


XLPE Insulated, PVC Sheathed Unarmoured 300mm2 4 Cores Copper Cable, 0.6/1kV

  • Number of cores 4
  • Cross section area 300mm2
  • Conductor Copper
  • Rated Voltage 600/1000 Volts
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

XLPE 300mm2 4 Cores Copper Cable Application

XLPE insulated 4-core power cables are normally used in power transmission and distribution systems. The 4-core XLPE cable is referred to as IEC60502 CU/XLPE/PVC 0.6/1KV.

These cables are used for outdoor and indoor installations in damp and wet applications. They are normally used for power distribution in urban networks, industrial plants and energy distribution. For mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage. Suitable where space is at a premium.

XLPE 300mm2 4 Cores Copper Cable Standard

IEC 60228 Conductors
IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV) up to 35kV(Um=40.5kV) - Part 1: Cables for rated voltages of 1 kV(Um=1.2kV) and 3 kV(Um=3.6kV)

CONSTRUCTION :

XLPE 300mm2 4Cores Copper Cable Construction
1. Conductor: Plain annealed copper, Class 1: solid conductor, or Class 2: stranded conductor
2. Insulation: Cross-linked polyethylene XLPE
3. Filler: Non-hygroscopic material
4. Binder tape: Non-hygroscopic material
5. Outer sheath: Polyvinyl chloride PVC

XLPE 4 Cores Copper Cable Construction

XLPE 4 Cores Copper Cable Construction

PARAMETER :

XLPE 300mm2 4 Cores Copper Cable Parameter

Cable Type: CU/XLPE/PVC
Operating voltage, U0 / U (V): 600/1000
Number of cores: 4
Nominal Area (mm2): 300
Conductor Stranding: 48
Insulation Thickness (mm): 1.8
Sheath Thickness (mm): 3.0
Cable Overall Diameter (O.D.) (mm): 63.5
Cable Weight Per 1000 Meters (kg): 12000
Resistance DC 20°C Per 1000 Meters (Ω): 0.0601
Allowable Ampacity in Air (Amps): 455
Allowable Ampacity  in Ground (Amps): 565
Test Voltage:
3.5kV for 5 minutes
Operating temperature (°C) : -15 to +90
Final short circuit temperature (°C):
250