XLPE Insulated 6mm2 4 Cores Copper Cable 4x6mm2

This is a 4-core copper cable with a cross-sectional area of 6mm² per core, insulated with XLPE and protected with a PVC sheath. Rated at 0.6/1kV, it is suitable for low to medium voltage power distribution applications. The XLPE insulation offers excellent thermal and electrical properties, ensuring safety, durability, and efficient performance. The PVC sheath provides additional protection against environmental factors, making the cable suitable for indoor and outdoor installations. As an unarmoured cable, it is typically installed in conduits, trunking, or cable trays, ideal for industrial, commercial, and residential electrical systems requiring reliable power transmission.

  • slide

XLPE Insulated 6mm2 4 Cores Copper Cable 4x6mm2


XLPE Insulated, PVC Sheathed Unarmoured 6mm2 4 Cores Copper Cable, 0.6/1kV

  • Number of cores 4
  • Cross section area 6mm2
  • Conductor Copper
  • Rated Voltage 600/1000 Volts
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

XLPE 6mm2 4 Cores Copper Cable Application

XLPE insulated 4-core power cables are normally used in power transmission and distribution systems. The 4-core XLPE cable is referred to as IEC60502 CU/XLPE/PVC 0.6/1KV.

These cables are used for outdoor and indoor installations in damp and wet applications. They are normally used for power distribution in urban networks, industrial plants and energy distribution. For mains, submains and subcircuits unenclosed, enclosed in conduit, buried direct or in underground ducts for buildings and industrial plants where not subject to mechanical damage. Suitable where space is at a premium.

XLPE 6mm2 4 Cores Copper Cable Standard

IEC 60228 Conductors
IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV) up to 35kV(Um=40.5kV) - Part 1: Cables for rated voltages of 1 kV(Um=1.2kV) and 3 kV(Um=3.6kV)

CONSTRUCTION :

XLPE 6mm2 4Cores Copper Cable Construction
1. Conductor: Plain annealed copper, Class 1: solid conductor, or Class 2: stranded conductor
2. Insulation: Cross-linked polyethylene XLPE
3. Filler: Non-hygroscopic material
4. Binder tape: Non-hygroscopic material
5. Outer sheath: Polyvinyl chloride PVC

XLPE 4 Cores Copper Cable Construction

XLPE 4 Cores Copper Cable Construction

PARAMETER :

XLPE 6mm2 4 Cores Copper Cable Parameter

Cable Type: CU/XLPE/PVC
Operating voltage, U0 / U (V): 600/1000
Number of cores: 4
Nominal Area (mm2): 6
Conductor Stranding: 1 or 7
Insulation Thickness (mm): 0.7
Sheath Thickness (mm): 1.8
Cable Overall Diameter (O.D.) (mm): 16.0
Cable Weight Per 1000 Meters (kg): 380
Resistance DC 20°C Per 1000 Meters (Ω): 3.08
Allowable Ampacity in Air (Amps): 47
Allowable Ampacity  in Ground (Amps): 64
Test Voltage:
3.5kV for 5 minutes
Operating temperature (°C) : -15 to +90
Final short circuit temperature (°C):
250