XV Cable

XV Cable is used for electricity supply in low voltage installation systems. It is well adapted to underground use in industrial applications with an additional mechanical protection. XV cable can be fixed on cable trays, within conduits or fixed to walls.

  • Xv Cable

XV Cable


Low Voltage Copper Codnductor Cable with XLPE Insulation and PVC Jacket

  • Rated Voltage 0.6/1kV
  • Conductor Material Plain annealed copper
  • Insulation Material XLPE
  • Sheath PVC
  • Standard IEC 60502-1


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

XV Cable Application

XV Cable is used for electricity supply in low voltage installation systems. It is well adapted to underground use in industrial applications with an additional mechanical protection. XV cable can be fixed on cable trays, within conduits or fixed to walls.

XV Cable Standard

NF C 32-321, IEC 60502-1, NF C 32-070 C2
Flame Retardant according to IEC 60332-1-2

CONSTRUCTION :

XV Cable construction

XV Cable construction

Conductor 1.5mm2 to 4mm2: Class 1 solid copper conductor*

6mm2 and above: Class 2 stranded copper conductor *

Class 2 stranded conductor available for these sizes on request

Insulation XLPE (Cross-Linked Polyethylene)

Filler: Not fibrous and not hygroscopic fill

Sheath PVC (Polyvinyl Chloride)

TECHNICAL DATA :

PHYSICAL PROPERTIES:
Minimum bending radius: 12 x Ø
Operation temperature range: -15 °C to 90 °C
Short-circuit temperature: 250 °C
ELECTRICAL PROPERTIES:
Working Voltage: 600/1000 volts
Test voltage: 3500 volts
Insulation resistance: 1000 MΩ x km

PARAMETER :

0.6/1kV-1 core copper conductor XLPE insulated PVC sheathed power cable
0.6/1kV-1 core copper conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of InsulationThickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
1X1.50.71.45.54812.12332
1X2.50.71.45.9597.413142
1X40.71.46.4754.614155
1X60.71.46.9953.085269
1X100.71.48.01401.837192
1X160.71.49.02001.1592115
1X250.91.410.63100.727120150
1X350.91.411.64100.524150180
1X501.01.413.15100.387180215
1X701.11.415.07100.268230265
1X951.11.516.89900.193285320
1X1201.21.518.412300.153335360
1X1501.41.620.514500.124385410
1X1851.61.622.618000.0991450460
1X2401.71.725.223000.0754535535
1x3001.81.827.829600.0601620605
1x4002.01.931.438000.0470720685
1x5002.22.034.948000.0366835775
1X6302.42.239.161000.0283960865
0.6/1kV-2 core copper conductor XLPE insulated PVC sheathed power cable
0.6/1kV-2 core copper conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of InsulationThickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
2X1.50.71.810.410512.12435
2X2.50.71.811.21357.413346
2X40.71.812.21754.614359
2X60.71.813.22303.085575
2X100.71.815.43401.8376100
2X160.71.817.44801.1597130
2X250.91.820.57000.727130165
2X350.91.822.59300.524160200
2X501.01.820.310000.387195240
2X701.11.823.314000.268245290
2X951.11.926.219500.193305355
2X1201.22.029.424500.153355405
2X1501.42.232.630000.124405450
2X1851.62.336.037000.0991465510
0.6/1kV-3 core copper conductor XLPE insulated PVC sheathed power cable
0.6/1kV-3 core copper conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of InsulationThickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
3X1.50.71.811.813512.12130
3X2.50.71.812.71807.412839
3X40.71.813.82254.613751
3X60.71.814.93003.084764
3X100.71.817.24301.836586
3X160.71.819.46301.1584110
3X250.91.822.89400.727110140
3X350.91.825.012500.524135170
3X501.01.824.415000.387170205
3X701.11.929.421400.268215250
3X951.12.033.629600.193265300
3X1201.22.135.937600.153310345
3X1501.42.339.944200.124350385
3X1851.62.444.159500.0991405435
3X2401.72.651.171000.0754480500
3X3001.82.756.190000.0601555565
3X4002.03.062.4100000.0470640640
0.6/1kV-4 core copper conductor XLPE insulated PVC sheathed power cable
0.6/1kV-4 core copper conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of InsulationThickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
4X1.50.71.812.616012.12130
4X2.50.71.813.62107.412839
4X40.71.814.82804.613751
4X60.71.816.03803.084764
4X100.71.818.65301.836586
4X160.71.821.08001.1584110
4X250.91.824.912400.727110140
4X350.91.828.316000.524135170
4X501.01.828.420000.387170205
4X701.12.033.128000.268215250
4X951.12.137.140000.193265300
4X1201.22.240.850000.153310345
4X1501.42.445.261000.124350385
4X1851.62.652.176000.0991405435
4X2401.72.857.895000.0754480500
4X3001.83.063.5120000.0601555565
4X4002.03.370.9160000.0470640640