N2XB2Y Cable

N2XB2Y cable is a robust, medium-voltage power cable designed for underground and industrial applications where mechanical protection is essential but tensile loads are limited. With cross-linked polyethylene (XLPE) insulation and a steel tape armoured construction, this cable offers high durability and reliable electrical performance under demanding conditions.

  • N2xb2y Cable

N2XB2Y Cable


Power cable 0,6/1 kV with Cu conductors, XLPE insulated and HDPE sheathed

  • Rated Voltage 0.6/1kV
  • Conductor Material Plain annealed copper
  • Insulation Material XLPE
  • Sheath HDPE
  • Armour Double galvanized steel tape
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

N2XB2Y cable is a robust, medium-voltage power cable designed for underground and industrial applications where mechanical protection is essential but tensile loads are limited. With cross-linked polyethylene (XLPE) insulation and a steel tape armoured construction, this cable offers high durability and reliable electrical performance under demanding conditions.

Application

N2XB2Y cables are suitable for:

  • Underground installations, including direct burial

  • Ducts, cable trays, and concrete environments

  • Water-saturated areas, provided the cable is not under continuous tensile stress

  • Power distribution systems in:

    • Electrical substations

    • Transformer stations

    • Industrial plants

    • Urban infrastructure and energy networks

These cables are specifically engineered to withstand moderate mechanical impacts, making them ideal for installation conditions requiring mechanical protection without exposure to significant tensile stress.

Applicable Standards

  • IEC 60502-1

  • HD 603 S1

CONSTRUCTION :

 N2XB2Y Cable Construction

N2XB2Y Cable Construction

Conductor: Copper  Class 1: solid conductor, or Class 2: stranded conductor
Insulation:Cross-linked polyethylene XLPE
Filler: Non-hygroscopic material
Binder tape: Non-hygroscopic material
Inner sheath: Polyvinyl chloride PVC
Armour: Double galvanized steel tape
Outer sheath: HDPE

Key Features

  • Excellent mechanical protection via steel tape armouring

  • High thermal resistance due to XLPE insulation

  • Water-resistant construction for wet or semi-wet installations

  • Non-hygroscopic bedding and fillers improve durability

  • Halogen-containing sheath (PVC inner, HDPE outer) for cost-effective ruggedness

PARAMETER :

NOMINAL CROSS-SECTIONMAX. RESISTANCE AT 20°CCURRENT CAPACITY IN AIRCURRENT CAPACITY IN EARTHOUTER DIAM. (APPROX.)CABLE WEIGHT (APPROX.)
mm²Ω/kmAAmmkg/km
2x44,61425214,2326
2x63,08536415,2390
2x101,83748617,2521
2x161,159811219,0706
2x250,72713314522,01001
2x350,52416217424,21275
2x500,38719720627,41729
2x700,26825025431,42299
3x101830748618,0637
3x1611509811219,9884
3x250,72713314523,21275
3x350,52416217424,51341
3x500,38719720628,32044
3x700,26825025432,52709
3x950,19330830535,73493
3x1200,15335934839,14363
3x1500,12441239243,25336
3x1850,099147544447,16470
3x2400,075456451752,58185
4x101830748619,3841
4x1611509811221,51162
4x250,72713314525,11671
4x350,52416217427,11847
4x500,38719720631,22741
4x700,26825025435,83662
4x950,19330830539,64821
4x1200,15335934843,45903
4x1500,12441239248,87290
4x1850,099147544453,28815
4x2400,075456451759,311194
5x101830748620,7885,6
5x1611509811223,11258,4
5x250,72713314527,21847,4
5x350,52416217430,22429,2
5x500,38719720635,63545,1
5x700,26825025440,74781,6
5x950,19330830545,46287,1
Need Help?