The U-1000 ARVFV armoured aluminium cables can be used in all low voltage power installations. This product is used in photovoltaic applications. These cables are suitable for direct burial without additional protection , for installation on cable trays or in conducts where mechanical protection is necessary.

  • U 1000 Arvfv Cable

U-1000 ARVFV Cable


Power cable 0,6/1 kV with AL conductors, XLPE insulated and Double Steel Tape Armoured

  • Rated Voltage 0.6/1kV
  • Conductor Material Aluminum conductor
  • Insulation Material Cross-linked polyethylene (XLPE)
  • Sheath PVC
  • Armour Double Galvansied Steel Tape


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

U-1000 ARVFV Industrial Cable Application

The U-1000 ARVFV armoured aluminium cables can be used in all low voltage power installations. This product is used in photovoltaic applications. These cables are suitable for direct burial without additional protection , for installation on cable trays or in conducts where mechanical protection is necessary.

U-1000 ARVFV Industrial Cable Standard:

NF C 32-322

CONSTRUCTION :
U-1000 ARVFV Industrial Cable Construction
U-1000 ARVFV Industrial Cable Construction

Conductor: Aluminum conductor,Strands to IEC 60228 class 2
Insulation: Cross-linked polyethylene (XLPE) insulation type XLPE according to IEC 60502-1.
Armour bedding: Black extruded PVC separation sheath.
Armour: Double steel or aluminium tape armour. Aluminium armour is used in single-core cables to avoid parasite currents that may overheat the cable. Steel tape is used in the multicore cables.Outer sheath: Flexible PVC outer sheath, Black colour.

The standard identification of insulated conductors is the following:
1 x Natural
2 x Blue + Brown
3 G Blue + Brown + Green/Yellow
3 x Brown + Black + Grey
3 x + 1 x Brown + Black + Grey + Blue (reduced cross-section)
4 G Brown + Black + Grey + Green/Yellow
4 x Brown + Black + Grey + Blue
5 G Brown + Black + Grey + Blue + Green/Yellow
6 or more Black numbered + Green/Yellow

CHARACTERISTICS :U-1000 ARVFV Industrial Cable Characteristics

Electrical performance: Low voltage 0,6/1kV.

Thermal performance:
Maximum service temperature: 90ºC.
Maximum short-circuit temperature: 250ºC (max. 5 s).
Minimum service temperature: -40ºC (fixed and protected installations).

Fire performance:
Flame non-propagation according to EN 60332-1 and IEC 60332-1.
Reduced halogen emission. Chlorine <15%.
Reaction to fire CPR: Eca, according to EN 50575.

Mechanical performance:
Minimum bending radius: x5 cable diameter.
Impact resistance: AG2 Medium severity.

Environmental performance
Chemical & Oil resistance: Good.
UV Resistant: UNE 211605.
Installation conditions
Open Air.
Buried.
In conduit.

Other
Meter by meter marking.

PARAMETER :
U-1000 ARVFV Industrial Cable Parameter

Cross SectionInsulation thicknessAmour thicknessMinimum Sheath thicknessMaximum Overall diameterApprox Cable weight
mm^2mmmmmmmmkg/km
2x100.70.21.418.5420
2x160.70.21.520.5540
2x250.90.21.624.5760
2x350.90.21.727930
3x100.70.21.519470
3x160.70.21.522590
3x250.90.21.626830
3x350.90.21.7291030
3x500.90.21.832.51290
3x701.10.2237.51710
3x951.10.52.143.52610
3x1201.20.52.347.53110
3x1501.40.52.4533770
3x1851.60.52.5584540
3x2401.70.52.765.55620
3x3001.80.52.9726830
3x50+351.0/090.21.934.51500
3x70+501.1/0.90.22402000
3x95+501.1/1.00.52.2452870
3x120+701.2/1.10.52.3503460
3x150+701.4/1.10.52.5544090
3x185+701.6/1.10.52.6594980
3x240+951.7/1.10.52.8666210
4x100.70.21.520.5540
4x160.70.21.623.5700
4x250.90.21.7281000
4x350.90.21.831.51230
4x5010.21.935.51550
4x701.10.52.142.52490
4x951.10.52.347.53120
4x1201.20.52.4533780
4x1501.40.52.658.54550
4x1851.60.52.764.55490
4x2401.70.52.972.56860
4x3001.80.53.179.58250
5x100.70.21.622.5640