NAYBY Cable

NAYBY cable is suitable for AC 50Hz power and distribution lines with rated voltage of 0.6/1kV, which can be used in fixed industrial power applications, underground tunnels, etc. Using steel wire armour offers great mechanical protection, making it rigid with a large radius.

  • Nayby Cable

NAYBY Cable


NAYBY Cable Low Voltage Aluminum Cable with Double Galvanized Steel Tape Armoured

  • Rated Voltage 0.6/1kV
  • Conductor Material Aluminum
  • Insulation Material Polyvinyl chloride PVC
  • Sheath Polyvinyl chloride PVC
  • Armour Double galvanized steel tape
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

Application

NAYBY cable is designed for fixed power distribution systems operating at AC 50Hz with a rated voltage of 0.6/1kV. It is ideally suited for:

  • Industrial power installations

  • Underground power networks

  • Cable trenches and tunnels

  • Outdoor and indoor fixed installations

Thanks to its double galvanized steel tape armor, NAYBY cable offers enhanced mechanical protection against external stress, making it suitable for harsh environments where rigidity and strength are required.


Standards

  • IEC 60228 – Conductors of insulated cables

  • IEC 60502-1 – Power cables with extruded insulation for rated voltages up to 1 kV (Um = 1.2 kV)

CONSTRUCTION :
NAYBY Cable Construction

NAYBY Cable Construction

ComponentDescription
ConductorCopper or aluminum, Class 1 (solid) or Class 2 (stranded)
InsulationPolyvinyl Chloride (PVC)
FillerNon-hygroscopic material
Binder TapeNon-hygroscopic material
Inner SheathPolyvinyl Chloride (PVC)
ArmourDouble galvanized steel tape (provides mechanical protection)
Outer SheathPolyvinyl Chloride (PVC), UV and moisture resistant

Technical Data

ParameterValue
Rated Voltage (Uo/U)0.6/1 kV (Um = 1.2 kV)
Nominal DC Voltage1.8/1.8 kV (core-earth / core-core)
Test Voltage4 kV
Operating Temperature (Fixed)-35°C to +70°C
Temperature (Flexed)+5°C to +70°C
Max Short Circuit Temp+160°C (for 5 seconds max)
Minimum Bending Radius15 × OD (single core), 12 × OD (multicore)

Key Features

  • Excellent mechanical strength due to steel tape armor

  • Flame retardant and UV-resistant outer sheath

  • High reliability in underground and fixed installations

  • Suitable for harsh and mechanically demanding environments

  • Long service life with low maintenance

0.6/1kV-3 core aluminum conductor PVC insulated steel tape armored PVC sheathed power cable

0.6/1kV-3 core aluminum conductor PVC insulated steel tape armored PVC sheathed power cable

Nominal cross sectional area

Insulation thickness

Non-magnetic steel tape thickness 

Sheath thickness

Approximate outer diameter

Approx.
weight

Max.D.C resistance of conductor(20℃)

Current carrying capacity 

mm2

mm

mm

mm

mm

kg/km

Ω/km

In Air(A)

In Ground(A)

3X2.5

0.8

0.2

1.8

14.3

276

12.1

-

-

3X4

1.0

0.2

1.8

16.1

347

7.41

-

-

3X6

1.0

0.2

1.8

17.3

397

4.61

-

-

3X10

1.0

0.2

1.8

19.9

510

3.08

38

54

3X16

1.0

0.2

1.8

22.3

634

1.91

51

71

3X25

1.2

0.2

1.8

25.9

833

1.2

66

92

3X35

1.2

0.2

1.8

27.2

961

0.868

81

110

3X50

1.4

0.2

1.9

31.1

1229

0.641

98

130

3X70

1.4

0.2

2.0

35.2

1577

0.443

120

160

3X95

1.6

0.5

2.2

41.3

2432

0.32

150

195

3X120

1.6

0.5

2.3

44.6

2824

0.253

180

225

3X150

1.8

0.5

2.5

49.4

3424

0.206

205

250

3X185

2

0.5

2.6

54.0

4045

0.164

235

285

3X240

2.2

0.5

2.8

60.6

5047

0.125

280

330

3X300

2.4

0.5

3.0

66.4

6024

0.1

320

370

0.6/1kV-4 core aluminum conductor PVC insulated steel tape armored PVC sheathed power cable

0.6/1kV-4 core aluminum conductor PVC insulated steel tape armored PVC sheathed power cable

Nominal cross sectional area

Insulation thickness

Non-magnetic steel tape thickness 

Sheath thickness

Approximate outer diameter

Approx.
weight

Max.D.C resistance of conductor(20℃)

Current carrying capacity 

mm2

mm

mm

mm

mm

kg/km

Ω/km

In Air(A)

In Ground(A)

4X2.5

0.8

0.2

1.8

14.9

320

12.1

-

-

4X4

1

0.2

1.8

17.2

396

7.41

-

-

4X6

1

0.2

1.8

18.5

457

4.61

-

-

4X10

1

0.2

1.8

21.5

597

3.08

38

54

4X16

1

0.2

1.8

24.1

747

1.91

51

71

4X25

1.2

0.2

1.8

28.1

989

1.2

66

92

4X35

1.2

0.2

1.9

29.8

1166

0.868

81

110

4X50

1.4

0.2

2.0

34.6

1537

0.641

98

130

4X70

1.4

0.5

2.2

40.0

2327

0.443

120

160

4X95

1.6

0.5

2.4

45.4

2951

0.32

150

195

4X120

1.6

0.5

2.5

49.5

3498

0.253

180

225

4X150

1.8

0.5

2.6

54.4

4191

0.206

205

250

4X185

2

0.5

2.8

60.0

5036

0.164

235

285

4X240

2.2

0.5

3.0

66.9

6229

0.125

280

330

4X300

2.4

0.5

3.2

73.4

7467

0.1

320

370

0.6/1kV-5 core aluminum conductor PVC insulated steel tape armored PVC sheathed power cable

0.6/1kV-5 core aluminum conductor PVC insulated steel tape armored PVC sheathed power cable

Nominal cross sectional area

Insulation thickness

Non-magnetic steel tape thickness 

Sheath thickness

Approximate outer diameter

Approx.
weight

Max.D.C resistance of conductor(20℃)

Current carrying capacity 

mm2

mm

mm

mm

mm

kg/km

Ω/km

In Air(A)

In Ground(A)

5X2.5

0.8

0.2

1.8

16.1

356

12.1

-

-

5X4

1

0.2

1.8

18.4

459

7.41

-

-

5X6

1

0.2

1.8

19.9

525

4.61

-

-

5X10

1

0.2

1.8

23.2

700

3.08

38

54

5X16

1

0.2

1.8

26.2

871

1.91

51

71

5X25

1.2

0.2

1.9

30.8

1174

1.2

66

92

5X35

1.2

0.2

2.0

32.7

1391

0.868

81

110

5X50

1.4

0.5

2.2

39.3

2224

0.641

98

130

5X70

1.4

0.5

2.3

43.9

2760

0.443

120

160

5X95

1.6

0.5

2.5

50.4

3574

0.32

150

195

5X120

1.6

0.5

2.6

54.4

4181

0.253

180

225

5X150

1.8

0.5

2.8

60.3

5093

0.206

205

250

5X185

2

0.5

3.0

66.1

6056

0.164

235

285

5X240

2.2

0.5

3.3

73.9

7520

0.125

280

330

5X300

2.4

0.5

3.5

81.5

9126

0.1

320

370

Need Help?