NA2XBY Cable

NA2XBY cable represents a proven solution for medium voltage power distribution applications requiring reliable performance, cost-effectiveness, and long-term durability. Its combination of aluminum conductors, XLPE insulation, and protective sheathing systems makes it ideal for underground distribution, industrial installations, and commercial applications.

  • Na2xby Cable

NA2XBY Cable


Low Voltage Aluminum XLPE Cable with Double Galvanized Steel Tape Armoured

  • Rated Voltage 0.6/1kV
  • Conductor Material Aluminum
  • Insulation Material XLPE
  • Sheath Polyvinylchloride compound PVC 5V-90
  • Armour Double galvanized steel tape
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

NA2XBY cable represents a premium medium voltage power cable solution designed for reliable electrical distribution in demanding applications.

What is NA2XBY Cable?

NA2XBY cable is a medium voltage power cable featuring cross-linked polyethylene (XLPE) insulation with aluminum conductors and PVC outer sheath. The designation 'NA2XBY' follows European cable naming conventions and indicates specific construction characteristics that make it suitable for underground distribution, industrial installations, and power transmission applications.

Cable Designation Breakdown N - Standard medium voltage cable according to VDE standards A - Aluminum conductor 2X - Cross-linked polyethylene (XLPE) insulation B - Moisture barrier (lead sheath or equivalent) Y - PVC outer sheath

NA2XBY Cable Application

NA2XBY cable represents a proven solution for medium voltage power distribution applications requiring reliable performance, cost-effectiveness, and long-term durability. Its combination of aluminum conductors, XLPE insulation, and protective sheathing systems makes it ideal for underground distribution, industrial installations, and commercial applications.

NA2XBY Cable Standards:

IEC 60228 Conductors
IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) - Part 1: Cables for rated voltages of 1 kV(Um=1.2kV) and 3 kV(Um=3.6kV)

CONSTRUCTION :
NA2XBY Cable Construction

NA2XBY Cable Construction

NA2XBY Cable Construction

Conductor: Copper or aluminum, Class 1: solid conductor, or Class 2: stranded conductor
Insulation:Cross-linked polyethylene XLPE
Filler: Non-hygroscopic material
Binder tape: Non-hygroscopic material
Inner sheath: Polyvinyl chloride PVC
Armour: Double galvanized steel tape
Outer sheath: Polyvinyl chloride PVC

TECHNICAL :

Voltage Rating Uo/U (Um) 0.6/1 (1.2)kV
Nominal Voltage DC (core-earth/core-core) :1.8/1.8kV
Test Voltage:4kV
Temperature Rating:
Flexed: 5°C to +90°C
Fixed: -35°C to +90°C
Maximum Short Circuit Temperature:
+250°C (max 5 seconds)
Minimum Bend Radius:
Single core: 15 x overall diameter
Multi core: 12 x overall diameter

Whether used in urban distribution networks, industrial facilities, or commercial buildings, NA2XBY cable provides the reliability and performance required for modern electrical infrastructure.

As electrical systems continue to evolve with smart grid technologies and renewable energy integration, NA2XBY cable remains a fundamental component in delivering safe, reliable, and efficient electrical power distribution for diverse applications worldwide.

PARAMETER :

0.6/1kV-1 core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable
0.6/1kV-1 core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessNon-magnetic steel tape thickness Sheath thicknessApproximate outer diameterApprox.Max.D.C resistance of conductor(20℃)Current carrying capacity 
weight
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
1X100.70.21.811.82063.085847
1X160.70.21.812.92471.917562
1X250.90.21.814.63101.210078
1X350.90.21.815.23520.86812094
1X5010.21.816.74230.641145110
1X701.10.21.818.55230.443190135
1X951.10.21.820.16290.32235160
1X1201.20.21.821.77380.253270185
1X1501.40.21.823.78770.206310205
1X1851.60.21.825.710310.164355235
1X2401.70.21.82812540.125--
1X3001.80.21.93114950.1--
1X40020.223519040.0778--
         
0.6/1kV-2 core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable
0.6/1kV-2 core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessNon-magnetic steel tape thickness Sheath thicknessApproximate outer diameterApprox.Max.D.C resistance of conductor(20℃)Current carrying capacity 
weight
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
2X2.50.70.21.813.423612.1-23
2X40.70.21.814.32697.41-30
2X60.70.21.815.33074.61-38
2X100.70.21.817.83973.085047
2X160.70.21.8204931.916462
2X250.90.21.823.36431.28678
2X350.90.21.824.67380.86810594
2X5010.21.827.28960.641125110
2X701.10.21.931.411640.443165135
2X951.10.2235.514800.32200160
2X1201.20.52.240.221640.253235185
2X1501.40.52.344.225720.206270205
2X1851.60.52.548.930890.164310235
0.6/1kV-3 core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable
0.6/1kV-3 core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessNon-magnetic steel tape thickness Sheath thicknessApproximate outer diameterApprox.Max.D.C resistance of conductor(20℃)Current carrying capacity 
weight
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
3X2.50.70.21.813.925712.1-23
3X40.70.21.814.82967.41-30
3X60.70.21.8163424.61-38
3X100.70.21.818.64473.085047
3X160.90.21.8215631.916462
3X250.90.21.824.67441.28678
3X350.90.21.8268690.86810594
3X5010.21.928.910740.641125110
3X701.10.2233.914430.443165135
3X951.10.52.23921830.32200160
3X1201.20.52.342.725930.253235185
3X1501.40.52.447.531550.206270205
3X1851.60.52.652.137430.164310235
3X2401.70.52.858.346410.125365260
3X3001.80.52.963.655080.1420290
0.6/1kV-4 core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable
0.6/1kV-4 core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessNon-magnetic steel tape thickness Sheath thicknessApproximate outer diameterApprox.Max.D.C resistance of conductor(20℃)Current carrying capacity 
weight
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
4X2.50.70.21.814.728812.1-23
4X40.70.21.815.83347.41-30
4X60.70.21.8173844.61-38
4X100.70.21.8205093.085047
4X160.90.21.822.76491.916462
4X250.90.21.826.78801.28678
4X350.90.21.828.310400.86810594
4X5010.22.13213650.641125110
4X701.10.52.138.521380.443165135
4X951.10.52.342.926380.32200160
4X1201.20.52.447.432020.253235185
4X1501.40.52.652.338470.206270205
4X1851.60.52.757.545850.164310235
4X2401.70.5364.357090.125365260
4X3001.80.53.170.368050.1420290
         
0.6/1kV-5 core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable
0.6/1kV-5 core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessNon-magnetic steel tape thickness Sheath thicknessApproximate outer diameterApprox.Max.D.C resistance of conductor(20℃)Current carrying capacity 
weight
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
5X2.50.70.21.815.632112.1-23
5X40.70.21.816.83767.41-30
5X60.70.21.818.24434.61-38
5X100.70.21.821.65923.085047
5X160.70.21.824.67631.916462
5X250.90.21.82910291.28678
5X350.90.21.93112360.86810594
5X5010.22.135.716160.641125110
5X701.10.52.342.425280.443165135
5X951.10.52.447.231720.32200160
5X1201.20.52.651.838010.253235185
5X1501.40.52.757.646040.206270205
5X1851.60.52.963.855740.164310235
5X2401.70.53.270.768590.125365260
5X3001.80.53.47883050.1420290
         
0.6/1kV-3+1core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable
0.6/1kV-3+1core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessNon-magnetic steel tape thickness Sheath thicknessApproximate outer diameterApprox.Max.D.C resistance of conductor(20℃)Current carrying capacity 
weight
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
3X4+1X2.50.7/0.70.21.815.53187.41/12.1-30
3X6+1X40.7/0.70.21.816.83714.61/7.41-38
3X10+1X60.7/0.70.21.819.34783.08/4.615047
3X16+1X100.7/0.70.21.822.16151.91/3.086462
3X25+1X160.9/0.70.21.825.17941.2/1.918678
3X35+1X160.9/0.70.21.826.89260.868/1.9110594
3X50+1X251/0.90.21.930.211750.641/1.2125110
3X70+1X351.1/0.90.2235.115700.443/0.868165135
3X95+1X501.1/1.00.52.240.423590.32/0.641200160
3X120+1X701.2/1.10.52.34528860.253/0.443235185
3X150+1X701.4/1.10.52.549.133960.206/0.443270205
3X185+1X951.6/1.10.52.854.340700.164/0.32310235
3X240+1X1201.7/1.20.52.859.148550.125/0.253365260
3X300+1X1501.8/1.40.536660280.1/0.206420290
         
0.6/1kV-4+1core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable
0.6/1kV-4+1core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessNon-magnetic steel tape thickness Sheath thicknessApproximate outer diameterApprox.Max.D.C resistance of conductor(20℃)Current carrying capacity 
weight
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
4X4+1X2.50.7/0.70.21.816.33657.41/12.1-30
4X6+1X40.7/0.70.21.817.74294.61/7.41-38
4X10+1X60.7/0.70.21.820.35613.08/4.615047
4X16+1X100.7/0.70.21.8247281.91/3.086462
4X25+1X160.9/0.70.21.828.19741.2/1.918678
4X35+1X160.9/0.70.21.929.611340.868/1.9110594
4X50+1X251/0.90.223415050.641/1.2125110
4X70+1X351.1/0.90.52.240.323510.443/0.868165135
4X95+1X501.1/1.00.52.344.829070.32/0.641200160
4X120+1X701.2/1.10.52.650.235880.253/0.443235185
4X150+1X701.4/1.10.52.854.642150.206/0.443270205
4X185+1X951.6/1.10.52.960.551330.164/0.32310235
4X240+1X1201.7/1.20.5367.162890.125/0.253365260
4X300+1X1501.8/1.40.53.273.775440.1/0.206420290
         
0.6/1kV-3+2 core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable
0.6/1kV-3+2 core aluminum conductor XLPE insulated steel tape armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessNon-magnetic steel tape thickness Sheath thicknessApproximate outer diameterApprox.Max.D.C resistance of conductor(20℃)Current carrying capacity 
weight
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
3X4+2X2.50.7/0.70.21.816.63547.41/12.1-30
3X6+2X40.7/0.70.21.8184164.61/7.41-38
3X10+2X60.7/0.70.21.820.95313.08/4.615047
3X16+2X100.7/0.70.21.8246941.91/3.086462
3X25+2X160.9/0.70.21.828.19201.2/1.918678
3X35+2X160.9/0.70.21.929.610340.868/1.9110594
3X50+2X251/0.90.223414000.641/1.2125110
3X70+2X351.1/0.90.52.240.321530.443/0.868165135
3X95+2X501.1/1.00.52.344.826580.32/0.641200160
3X120+2X701.2/1.10.52.550.233290.253/0.443235185
3X150+2X701.4/1.10.52.654.637900.206/0.443270205
3X185+2X951.6/1.10.52.860.545750.164/0.32310235
3X240+2X1201.7/1.20.5367.155640.125/0.253365260
3X300+2X1501.8/1.40.53.273.768010.1/0.206420290
Need Help?