Single Core 8.7/15KV Medium Voltage Aluminum Wire Armoured Cable

The Single Core 8.7/15kV Medium Voltage Aluminum Wire Armoured Cable is designed for reliable power transmission at medium voltage levels, featuring an aluminum conductor, XLPE insulation for excellent electrical and thermal performance, steel tape or wire armour for mechanical protection, and a durable outer sheath. It is suitable for underground and outdoor installations in industrial and civil power distribution systems, offering durability, safety, and efficient electrical performance.

  • Single Core 8.7 15kv Medium Voltage Aluminum Wire Armoured Cable

Single Core 8.7/15KV Medium Voltage Aluminum Wire Armoured Cable


Single Core 8.7/15KV (Um=17.5KV) Armoured

  • Rated Voltage 8.7/15kV
  • Conductor Material Copper or Aluminum
  • Operating Temperature up to 90°C
  • Short Circuit Temperature 250°C
  • Bending Radius 12 x OD


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

Single Core 8.7/15KV Medium Voltage Aluminum Wire Armoured Cable Application

The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.8/6.6KV to 19/33KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

Single Core 8.7/15KV Medium Voltage Aluminum Wire Armoured Cable Standard

BS 6622, IEC60502-2, BS 7835 (LSZH Version)

CONSTRUCTION :
Single Core 8.7/15KV Medium Voltage Aluminum Wire Armoured Cable Construction

Single Core 8.7/15KV Medium Voltage Aluminum Wire Armoured Cable Construction

Single Core 8.7/15KV Medium Voltage Aluminum Wire Armoured Cable Construction

Conductor: Plain annealed copper or aluminium wire. Copper conductors shall be stranded (class 2) and aluminium conductors shall be either solid or stranded (class 2).
Conductor Screen: Extruded layer of semi-conducting cross-linkable compound.
Insulation: cross-linked polyethylene compound XLPE or EPR.
Insulaton Screen: Extruded layer of semi-conducting cross-linkable compound is applied over the insulation.
Metallic Layer: copper tapes or a concentric layer of copper wires or a combination of tapes and wires.
Separation Sheath (for armoured cable): PVC, PE or LSZH.
Armour (for armoured cable): round aluminium wire.
Over Sheath: PVC or MDPE. LSZH can be offered as an option.

DIMENSIONAL DATA :
Single Core 8.7/15KV Medium Voltage Aluminum Wire Armoured Cable Dimensional Data

Nom. Cross-Section Area Aluminium Wire Armoured Cables
Nom. Insulation ThicknessCopper Tape Screen AreaNom. Bedding ThicknessNom. Armour Wire DiameterNom. Sheath ThicknessApprox. Overall DiameterApprox. Weight
CUAL
mm^2mmmm^2mmmmmmmmkg/km
254.54.41.21.61.830.314301210
354.54.71.21.61.931.516301310
504.54.91.21.61.932.617301410
704.55.31.21.61.934.219701520
954.55.71.22236.823701770
1204.56.11.222.138.426701910
1504.56.41.222.140.130202080
1854.56.81.222.241.834202240
2404.57.41.222.344.540502500
3004.57.91.222.346.546802780
4004.58.51.32.52.551.859703430
5004.59.21.32.52.654.470103910
6304.5101.42.52.759.884804420
Need Help?