KVV22 Control Cable-PVC Insulated Steel Tape Armoured Copper Cables

KVV22 is a steel tape armoured control cable with copper conductor and PVC insulation/sheath, designed for fixed installations where moderate mechanical protection is required. It offers excellent resistance to heat, cold, aging, and chemicals, making it ideal for complex industrial environments. This cable can also be customized with flame-retardant, fire-resistant, or low-smoke halogen-free (LSZH) properties upon request.

  • Kvv22 Control Cable Pvc Insulated Steel Tape Armoured Copper Cables

KVV22 Control Cable-PVC Insulated Steel Tape Armoured Copper Cables


KVV22 Control Cable-PVC Insulated Steel Tape Armoured Copper Cables

  • Rated Voltage 450/750 Volts
  • Conductor Material soft annealed copper
  • Insulation PVC
  • Sheath PVC
  • Armour Armoured material Steel tape


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

KVV22 is a steel tape armoured control cable with copper conductor and PVC insulation/sheath, designed for fixed installations where moderate mechanical protection is required. It offers excellent resistance to heat, cold, aging, and chemicals, making it ideal for complex industrial environments. This cable can also be customized with flame-retardant, fire-resistant, or low-smoke halogen-free (LSZH) properties upon request.

Application

KVV22 control cables are suitable for use in control, monitoring, and protection circuits in the following environments:

  • Indoor installations

  • Underground and in trenches

  • Cable ducts and control panels

  • Industrial plants and power stations

  • Locations requiring mechanical protection against moderate external forces


Standards

  • IEC 60227 – Polyvinyl chloride insulated cables

  • IEC 60502 – Power cables with extruded insulation

  • GB/T 9330 – Control cables

  • BS 6500 – Flexible cords and cables


Control Cable Variants

Model Name Main Application
KVV Copper conductor, PVC insulated and sheathed control cable Fixed indoor installation, in ducts or trenches
KVVP Same as KVV, with copper wire braid shielding For shielding against electromagnetic interference
KVVP2 Steel tape shielded version Fixed installation with greater mechanical protection
KVV22 Steel tape armoured version For underground or trench installations with moderate mechanical force
KVVR Flexible version of KVV For indoor use where flexibility and movement are needed
ZR-KVVRP Flame-retardant, flexible, shielded For indoor environments requiring shielding and fire protection
ZR-KVV Flame-retardant KVV For flame-resistant indoor or trench installations
ZR-KVVP2 Flame-retardant with steel tape shielding For fixed installations with mechanical and flame-resistance requirements
ZR-KVV22 Flame-retardant with steel tape armour Underground/trench installations with higher external mechanical forces and flame resistance
ZR-KVVR Flame-retardant, flexible version For flexible indoor applications requiring flame resistance

Technical Data

Parameter Value
Standards IEC 60227, IEC 60502, GB/T 9330, BS 6500
Rated Voltage 450/750V
Conductor Material Copper, Class 1 or 2
Insulation & Sheath PVC
Armour Type Steel Tape
Application Industrial control circuits
Chemical Resistance Good resistance to chemicals and oil
Mechanical Performance Min. bending radius: 20 × cable diameter
Fire Performance Flame non-propagation (IEC 60332-1)
Halogen emission: < 15% chlorine
Temperature Range Max. service temp: 70°C
Max. short-circuit temp (5s): 160°C
Min. installation temp: -15°C

Key Features

  • Excellent durability and mechanical strength

  • Flame-retardant and chemical resistant

  • Steel tape armour for underground and trench installations

  • Multiple versions available for shielding, flexibility, and fire performance

 

KVV22 Control Cable CU/PVC/STA/PVC
Nominal
Size
Conductor Structure Insulation Thickness Thickness of Inner Sheath  Thickness of Steel Tape Sheath Thickness Approx. Overall Dia. Approx. Weight Nominal
Size
Conductor Structure Insulation Thickness Thickness of Inner Sheath  Thickness of Steel Tape Sheath Thickness Approx. Overall Dia. Approx. Weight
mm2 No./mm mm mm mm mm mm kg/km mm2 No./mm mm mm mm mm mm kg/km
5×0.75 1/0.97 0.6 1.1  0.2  1.5  12.00  231 5×0.75 7/0.37 0.6 1.1  0.2  1.5  12.39  241
6×0.75 1/0.97 0.6 1.1  0.2  1.5  12.67  258 6×0.75 7/0.37 0.6 1.1  0.2  1.5  13.11  271
7×0.75 1/0.97 0.6 1.1  0.2  1.5  12.67  264 7×0.75 7/0.37 0.6 1.1  0.2  1.5  13.11  276
8x0.75 1/0.97 0.6 1.1  0.2  1.5  13.35  289 8x0.75 7/0.37 0.6 1.2  0.2  1.5  13.83  303
10x0.75 1/0.97 0.6 1.2  0.2  1.5  14.93  348 10x0.75 7/0.37 0.6 1.2  0.2  1.5  15.51  366
12x0.75 1/0.97 0.6 1.2  0.2  1.5  15.28  373 12x0.75 7/0.37 0.6 1.2  0.2  1.5  15.88  391
14x0.75 1/0.97 0.6 1.2  0.2  1.5  15.87  407 14x0.75 7/0.37 0.6 1.2  0.2  1.5  16.51  427
16x0.75 1/0.97 0.6 1.2  0.2  1.5  16.51  445 16x0.75 7/0.37 0.6 1.2  0.2  1.5  17.20  468
19x0.75 1/0.97 0.6 1.2  0.2  1.5  17.19  490 19x0.75 7/0.37 0.6 1.2  0.2  1.5  17.92  515
24x0.75 1/0.97 0.6 1.2  0.2  1.7  19.64  606 24x0.75 7/0.37 0.6 1.2  0.2  1.7  20.52  638
27x0.75 1/0.97 0.6 1.2  0.2  1.7  19.99  642 27x0.75 7/0.37 0.6 1.2  0.2  1.7  20.89  676
30x0.75 1/0.97 0.6 1.2  0.2  1.7  20.58  688 30x0.75 7/0.37 0.6 1.2  0.2  1.7  21.51  724
37x0.75 1/0.97 0.6 1.2  0.2  1.7  21.90  795 37x0.75 7/0.37 0.6 1.2  0.2  1.7  22.92  837
44x0.75 1/0.97 0.6 1.2  0.2  1.7  24.16  928 44x0.75 7/0.37 0.6 1.2  0.2  1.7  25.12  965
48x0.75 1/0.97 0.6 1.2  0.2  1.7  24.31  963 48x0.75 7/0.37 0.6 1.2  0.2  1.7  25.49  1014
52x0.75 1/0.97 0.6 1.2  0.2  1.7  24.89  1020 52x0.75 7/0.37 0.6 1.2  0.2  1.7  26.12  1075
61x0.75 1/0.97 0.6 1.2  0.2  1.7  26.22  1149 61x0.75 7/0.37 0.6 1.2  0.2  1.7  27.53  1211
Need Help?