NFC 33-209 Aerial Bundle Conductor ABC Cable 2x16mm2

This NFC 33-209 Aerial Bundle Conductor (ABC) Cable 2x16mm² is a low-voltage power cable designed for overhead line applications. It features two 16mm² stranded aluminum conductors insulated with XLPE. The conductors are twisted together to form a compact cable bundle. It's specifically manufactured to the National French Standard NFC 33-209.

  • Nfc 33 209 Aerial Bundle Conductor Abc Cable 2x16mm2

NFC 33-209 Aerial Bundle Conductor ABC Cable 2x16mm2


2*16mm2 Twist Cable Overhead Line with Aluminum Conductor XLPE Insulation

  • Conductor Stranded Round Aluminum Conductor
  • Insulation XLPE
  • Voltage 0.6/1kV
  • Number of cores 2 Core
  • Package 100 Meters One Roll with Export Wooden Case & Pallet


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

This NFC 33-209 Aerial Bundle Conductor (ABC) Cable 2x16mm² is a low-voltage power cable designed for overhead line applications. It features two 16mm² stranded aluminum conductors insulated with XLPE. The conductors are twisted together to form a compact cable bundle. It's specifically manufactured to the National French Standard NFC 33-209.


Applications

This 2x16mm² ABC cable is used to supply power from a pole-mounted transformer to the user's service head. It is suitable for applications with a voltage of 600V or less, phase to phase. The XLPE insulation allows for conductor temperatures up to 90°C.


Standards Compliance

The cable is manufactured in accordance with the following standards:

  • Aerial Bundled Conductors: National French Standard NFC 33-209
  • Insulation and Extruded Cables: IEC 60502-1

Construction Details

2 core ABC Cable Construction

The construction of the 2-core ABC cable consists of:

  • Phase Conductor: Round stranded compressed aluminum (RM).
  • Insulation: Black XLPE.
  • Assembly: The cores are stranded together with a right-hand lay.

Technical Data & Parameters

ParameterValue
Standards ReferenceIEC 60502-1, NFC 33-209
Rated Voltage0.6/1 kV
Test Voltage4 kV (Veff)
Type of Cable2x16mm²
Conductor MaterialStranded Aluminum wire
Stranding (No. of wires)7
Approx. Diameter of Conductor5.0 mm
Insulation MaterialBlack XLPE
Nominal Thickness of Insulation1.2 mm
Approx. Diameter of Insulated Conductor7.5 mm
Approx. Overall Diameter of Cable15.0 mm
Max. DC Resistance @ 20°C1.91 /km
Approx. Weight of Cable132 kg/km
Laying Temperature (min.)-5°C
Operating Temperature-15°C to +90°C
Conductor Temperature (max.)+90°C
Short-Circuit Temperature (max.)+250°C for 5 seconds
Bending Radius (min.)15 x Ø of cable
Need Help?