SIP-4 Cable

The SIP-4 cable is a type of Self-supporting Insulated Overhead Wire used for low-voltage power distribution. Its name is an acronym for Self-supporting Insulated Polar wire, with "4" denoting its specific design type. A key feature of SIP-4 is that it does not have a separate messenger (load-bearing) wire; all the insulated conductors are self-supporting. The conductors are made of compacted aluminum and insulated with XLPE (cross-linked polyethylene).

  • Sip 4 Cable

SIP-4 Cable


Self-supporting Insulated Overhead Wire Cable SIP-4

  • Voltage 0.6/1kV
  • Conductor Aluminum Conductor
  • Insulation XLPE
  • Number of cores 2-5 cores
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

The SIP-4 cable is a type of Self-supporting Insulated Overhead Wire used for low-voltage power distribution. Its name is an acronym for Self-supporting Insulated Polar wire, with '4' denoting its specific design type. A key feature of SIP-4 is that it does not have a separate messenger (load-bearing) wire; all the insulated conductors are self-supporting. The conductors are made of compacted aluminum and insulated with XLPE (cross-linked polyethylene).

Applications

SIP-4 cables are versatile and used for a variety of low-voltage distribution purposes, including:

  • Powering end-consumer facilities and residential areas.
  • Building lighting power grids.
  • Laying on the walls of construction sites.
  • Equipping branches from overhead power lines to transformer units.

Unlike other ABC cables that rely on a separate neutral messenger wire for support, SIP-4 relies on the combined strength of all its conductors. This makes installation faster and simpler in some cases.

SPECIFICATION :

Specifications
Permissible heating temperature of current-carrying conductors during overload mode (up to 8 hours per day)130°С
Permissible heating temperature of current-carrying conductors in case of short circuit with short circuit current flow up to 5 seconds250°С
Operating temperatureот -60 °С до +50 °С
Minimum wire laying temperature-20 °С
Long-term permissible core heating temperature+90 °С
Minimum bending radius when laying10 wire diameters
Minimum service life25 years

Parameter

Number and nominal cross-section of conductors, mm2Outer wire diameter, mmEstimated weight of 1 km of wire / 1kgNominal insulation thickness
SIP-4 2х1617.2142.61.3
SIP-4 2х2519.8205.51.3
SIP-4 3х1615.72061.3
SIP-4 3х2518.12921.3
SIP-4 4х1620.08285.31.3
SIP-4 4х2523.9410.91.3
SIP-4 4х3527.1544.71.3
SIP-4 4х5030.9730.81.5
SIP-4 4х7035.61014.11.7
SIP-4 4х9541.51358.51.7
SIP-4 4х12045.21683.21.7
Need Help?