SIP-3 Cable 20kV 35KV

The SIP-3 cable is a single-core, self-supporting insulated wire designed for medium-voltage overhead power transmission lines. Its conductors are made from a compact aluminum alloy, and the insulation is a light-stabilized XLPE that is resistant to UV radiation and ozone. The key difference between SIP-3 and other SIP cables is its high-voltage rating, suitable for 20kV and 35kV networks.

  • Sip 3 Cable 20kv 35kv

SIP-3 Cable 20kV 35KV


Self-supporting Insulated Overhead Wire Cable SIP-3

  • Conductor Aluminum Alloy Conductor
  • Insulation XLPE
  • Voltage 20kV 35kV
  • Number of cores Single Core
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

The SIP-3 cable is a single-core, self-supporting insulated wire designed for medium-voltage overhead power transmission lines. Its conductors are made from a compact aluminum alloy, and the insulation is a light-stabilized XLPE that is resistant to UV radiation and ozone. The key difference between SIP-3 and other SIP cables is its high-voltage rating, suitable for 20kV and 35kV networks.


Key Specifications & Construction

  • Voltage: 20kV and 35kV.
  • Conductor: Bare alloy aluminum conductor (AlMgSi), round stranded compressed (RM). The conductor is longitudinally watertight due to a dry filling.
  • Insulation: Black, UV-resistant XLPE. The SIPn-3 variant uses XLPE that does not spread combustion.
  • Core Count: Single Core.
  • Standards: The cable adheres to a self-supporting design for medium-voltage lines.
  • Service Life: Minimum 25 years.

Deciphering the Name

  • S – self-supporting
  • I – insulated
  • P – wire
  • 3 – design type for protective insulation
  • n – does not support combustion (for SIPn-3)
  • AAsXS – (A)luminum conductor, (s)elf-supporting, (XS) XLPE insulation.

Technical Data

  • Long-term Conductor Heating: C
  • Overload (up to 8 hrs/day): C
  • Short Circuit (up to 5s): C
  • Operating Temperature: C to C
  • Minimum Laying Temperature: C
  • Minimum Bending Radius: 10 times the wire diameter

 

Parameters for 20kV SIP-3 Cable

Cores x Cross Section (No.xmm²) Nominal Insulation Thickness (mm) Overall Diameter (mm) Weight (kg/km) Max Conductor Resistance (/km)
1x35 2.3 12 165 0.986
1x50 2.3 13 215 0.720
1x70 2.3 15 282 0.630
1x95 2.3 16 364 0.363
1x120 2.3 18 445 0.288
1x150 2.3 19 540 0.236
1x185 2.3 21 722 0.188
1x240 2.3 24 950 0.145

 

Parameters for 35kV SIP-3 Cable

Cores x Cross Section (No.xmm²) Nominal Insulation Thickness (mm) Overall Diameter (mm) Weight (kg/km) Max Conductor Resistance (/km)
1x35 3.5 14 209 0.986
1x50 3.5 16 263 0.720
1x70 3.5 17 334 0.630
1x95 3.5 19 421 0.363
1x120 3.5 20 518 0.288
1x150 3.5 22 618 0.236
1x185 3.5 24 808 0.188
1x240 3.5 26 1045 0.145