Copper Concentric Cable 2*8awg 2*10awg ASTM Standard

A copper concentric cable with 2 x 8 AWG and 2 x 10 AWG conductors, conforming to ASTM standards, is a type of electrical cable designed for service entrance and feeder applications. It features a central conductor(s) surrounded by a concentric neutral layer, often used in situations where preventing electricity theft is a concern. These cables are suitable for use in both dry and wet locations, including direct burial and outdoor installations.

  • Copper Concentric Cable Astm Standard

Copper Concentric Cable 2*8awg 2*10awg ASTM Standard


Copper Concentric Cable 2*8awg 2*10awg ASTM Standard

  • Type of cable Copper Concentric Cable
  • Phase Conductor Copper
  • Insulation XLPE
  • Neutral Conductor Copper Wire
  • Sheath PVC (XLPE/PE) sheath


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

Copper Concentric Cable Standard

IEC60502-1, BS7870, ASTMD2655
ASTMB556, ASTMB193, ASTMB8, UL44, UL1581, UL854

Key features of this cable include:

  • Conductors: Both 8 AWG and 10 AWG conductors are made of copper.
  • Concentric Neutral: The concentric layer is also made of copper.
  • Insulation: The conductors are insulated, typically with XLPE (cross-linked polyethylene) or PVC (polyvinyl chloride).
  • Sheath: A PVC jacket typically provides protection for the entire assembly.
  • Voltage Rating: Commonly rated for 600V applications.
  • Temperature Rating: Maximum operating temperature is typically 90°C.
  • Standards: Conforms to ASTM standards and may also be designed to meet other standards like IEC, BS, or client specifications. 

Typical applications:

  • Service Entrance: From the power distribution network to the meter panel.
  • Feeder Cable: From the meter panel to the distribution panel.
  • Underground: Direct burial applications are suitable.
  • Outdoor: Suitable for outdoor installations.
  • Where preventing electricity theft is a concern: The concentric design helps prevent tampering. 

CONSTRUCTION

Copper Concentric Cable Standard Construction

Copper Concentric Cable Standard Construction

1.Phase conductor: Copper conductor
2.Insulation :XLPE
3.Neutral conductor :Copper wire
4.Binder tape :Non-hygroscopic tape
5.Sheathed:PVC (XLPE/PE) sheath

Copper Concentric Cable ASTM Standard
Core and
Nominal Cross Section
Conductor StructureInsulation
 Thickness
Concentric conductorThickness
of cable shield
Overall 
Diameter
Cable
Weight
Max DC resistance of conductor (20℃)
Wire gaugeNumberDiameter mmmmNumberDiameter mmmmmmkg/kmΩ/km (Phase)Ω/km (Concentric)
Copper conductor (US standard)
2X #1270.781.14390.3211.147.741085.435.50
2X #1070.981.14250.5111.148.721513.413.50
2X #871.231.14250.6431.149.742142.142.20
2X #671.551.14250.8131.1411.043131.351.40
2X #471.961.14261.0201.1412.684720.8480.85
3X #871.231.14650.4051.1411.3X17.34182.142.20
3X #671.551.14650.5111.5213.2X20.26201.351.40
3X #471.961.14650.6431.5214.7X22.98750.8480.85
3X #272.471.14650.8231.5216.6X26.312750.5240.53
Aluminum alloy conductor (US standard)
2X #1270.781.14390.3211.147.74678.888.90
2X #1070.981.14250.5111.148.72855.595.60
2X #871.231.14250.6431.149.741103.523.60
2X #671.551.14250.8131.1411.041482.212.30
2X #471.961.14261.0201.1412.682061.391.40
3X #871.231.14650.4051.1411.3X17.32623.523.60
3X #671.551.14650.5111.5213.2X20.23702.212.30
3X #471.961.14650.6431.5214.7X22.94881.391.40
3X #272.471.14650.8231.5216.6X26.36400.880.89
Need Help?