AAC-All Aluminum Stranded Conductor CSA C49

AAC All Aluminum Conductor to CSA C49 is a bare overhead conductor widely used in Canadian power transmission lines. It's a popular choice due to its simple construction, ease of installation, and low cost. The conductor is suitable for a wide range of applications, including installations across rivers and valleys.

  • Aac All Aluminum Stranded Conductor Csa C49

AAC-All Aluminum Stranded Conductor CSA C49


AAC CSA C 49 Stranded Aluminum Conductors Canadian Sizes

  • Nominal Area circular and sectional
  • Sectional area 6AWG to 3500MCM
  • Insulation N/A
  • Standard ASC CSA C49


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

AAC (All Aluminum Conductor) to CSA C49 is a bare overhead conductor widely used in Canadian power transmission lines. It's a popular choice due to its simple construction, ease of installation, and low cost. The conductor is suitable for a wide range of applications, including installations across rivers and valleys.


Key Specifications

  • Standard: CSA C49, which covers stranded aluminum conductors for Canadian sizes.
  • Conductor Material: Consists of concentric-lay-stranded hard-drawn 1350-H19 aluminum wires with a minimum purity of 99.55%.
  • Construction: The wires are helically wrapped around a central core, with each successive layer having six more wires than the one beneath it.
  • Insulation: None; this is a bare conductor.
  • Nominal Area: The conductor is available in a wide range of sizes, from 6 AWG to 3500 MCM.
  • Temperature Rating: Designed for continuous use at temperatures up to C.

Application Classes

The conductor's flexibility is defined by its class:

  • Class AA: Used for bare overhead lines, this is the least flexible class.
  • Class A: Used for conductors with weather-resistant coverings or where greater flexibility is needed.
  • Compact Strand: An option for bare overhead applications or with weather-resistant coverings, offering increased flexibility.

Parameter Table

Code Word AWG & MCM Sectional Area (mm²) Stranding Overall Diameter (mm) Breaking Load (kN) D.C. Resistance (/km) Current Rating (A)
Rose 4 21.16 7/1.96 mm 5.89 4.1 1.35 110
Lily 3 26.65 7/2.20 mm 6.61 5.0 1.072 124
Iris 2 33.61 7/2.47 mm 7.42 6.2 0.8497 136
Pansy 1 42.39 7/2.77 mm 8.33 7.6 0.6739 157
Poppy 1/0 53.48 7/3.12 mm 9.36 9.2 0.5341 180
Aster 2/0 67.42 7/3.50 mm 10.51 11.6 0.4236 207
Phlox 3/0 85.03 7/3.93 mm 11.82 14.1 0.3362 237
Oxlip 4/0 107.2 7/4.41 mm 13.25 17.7 0.2664 273
Valerian 250 126.7 19/2.91 mm 14.57 22.3 0.2274 305
Daisy 266.8 135.16 7/4.96 mm 14.9 22.4 0.2113 313
Tulip 336.4 170.45 19/3.38 mm 16.91 29.4 0.1638 364
Canna 397.5 201.42 19/3.67 mm 18.36 34.0 0.1427 401
Cosmos 477 241.68 19/4.02 mm 20.12 40.0 0.1188 447
Zinnia 500 253.35 19/4.12 mm 20.66 41.9 0.1132 459
Dahlia 556.5 282 19/4.34 mm 21.73 46.7 0.1018 489
Orchid 636 322.26 37/3.33 mm 23.31 55.6 0.0896 531
Violet 715.5 362.58 37/3.53 mm 24.74 62.5 0.0797 570
Arbutus 795 402.84 37/3.72 mm 26.06 68.1 0.0715 605
Magnolia 954 483.42 37/4.07 mm 28.55 80.0 0.0597 675
Marigold 1113 563.93 61/3.43 mm 30.89 97.2 0.0512 738
Narcissus 1272 644.51 61/3.66 mm 33.02 108.8 0.0457 797
Carnation 1431 725.16 61/3.89 mm 35.03 119.9 0.0408 854
Corepsis 1590.5 805.68 61/4.09 mm 36.91 133.2 0.0358 907
-1700 1700 861.42 61/4.23 mm 38.15 142.6 0.0335 942
-1800 1800 912.06 61/3.57 mm 39.28 153.9 0.0316 975
Need Help?