E-AY2Y cable is a low voltage power distribution cable with an aluminum conductor, designed for fixed installations in a wide range of environments. With its robust polyethylene (HDPE) outer sheath and UV resistance, it is suitable for both indoor and outdoor use, including direct burial, duct, and water-permissible installations under local regulations. This cable is ideal for power stations, industrial facilities, switchgears, and local mains distribution.
Application
E-AY2Y cables are designed for:
-
Power distribution in industrial plants, substations, and utility networks
-
Fixed installation underground, in concrete, ducts, interior spaces, and outdoors
-
Installations in water (where permitted by local codes)
-
Areas subject to moderate mechanical stress during installation and operation
Its aluminum conductor provides a lightweight, cost-effective alternative to copper in large-scale installations where mechanical flexibility and corrosion resistance are important.
E-AY2Y Cable Standard
-
IEC 60502-1
-
HD 603 S1
-
ÖVE E8200-603
CONSTRUCTION :
| Component | Description |
|---|---|
| Conductor | Aluminium, Class 1 (solid) or Class 2 (stranded), per EN 60228 |
| Insulation | PVC (Polyvinyl Chloride), core insulation |
| Filling Layer | PVC core covering (FM) or non-hygroscopic binding tape (BD) |
| Outer Sheath | Black Polyethylene (HDPE), UV-resistant and weatherproof |
TECHNICAL :
| Parameter | Value |
|---|---|
| Rated Voltage (Uo/U) | 0.6/1 kV |
| Test Voltage | 4,000 V AC |
| Max. Short-Circuit Duration | 5 seconds |
| Bending Radius | Single-core: 15 × D Multi-core: 12 × D |
| Flame Retardancy | EN 60332-1-2 (CPR Class Eca) |
Why Choose TOT Cable for E-AY2Y?
TOT Cable delivers high-quality E-AY2Y cables manufactured to strict international standards. With our focus on competitive pricing, technical reliability, and fast delivery, we support electrical distributors, contractors, and infrastructure developers worldwide.
PARAMETER :
|
Nu'mber of cores x Cross-section |
Overall diameter (approx.) [mm] |
Weight (approx.) [kg/km] |
Maximum electrical resistance at 20℃ [Ω/km] |
|
1x120 RM |
19 |
520 |
0.253 |
|
1x150 RM |
22 |
630 |
0.206 |
|
1x185 RM |
25 |
750 |
0.164 |
|
1x240 RM |
27 |
980 |
0.125 |
|
1x300 RM |
29 |
1200 |
0.1 |
|
3x240 SM + 120 SM |
55 |
3900 |
0.125 / 0.253 |
|
4x16 RM |
21 |
550 |
1.91 |
|
4x25 RM |
24 |
780 |
1.2 |
|
4x25 RE |
22 |
720 |
1.2 |
|
4x35 RM |
26 |
790 |
0.868 |
|
4x35 SM |
25 |
730 |
0.868 |
|
4x50 SM |
28 |
1100 |
0.641 |
|
4x50 SE |
26 |
1000 |
0.641 |
|
4x70 SM |
31 |
1350 |
0.443 |
|
4x70 SE |
30 |
1210 |
0.443 |
|
4x95 SM |
36 |
1800 |
0.32 |
|
4x95 SE |
34 |
1720 |
0.32 |
|
4x150 SM |
43 |
2700 |
0.206 |
|
4x150 SE |
41 |
2580 |
0.206 |
|
4x185 SM |
47 |
3080 |
0.164 |
|
4x185 SE |
46 |
2930 |
0.164 |
|
4x240 SE |
53 |
4140 |
0.125 |
|
4x240 SM |
54 |
4200 |
0.125 |
|
4x300 SM |
60 |
4630 |
0.1 |