YJLV Cable

YJLV Cable is a low-voltage power cable with XLPE insulation and aluminum conductor, designed for fixed installations in industrial environments, urban distribution networks, and infrastructure projects. With a rated voltage of 0.6/1kV, it is widely used for power transmission and distribution where flexibility and cost-efficiency are key.

  • Yjlv Cable

YJLV Cable


0.6/1kV XLPE Insulated, PVC Sheathed Low Voltage Cable

  • Rated Voltage 0.6/1kV
  • Conductor Material Aluminum
  • Insulation Material XLPE
  • Sheath Polyvinylchloride compound PVC 5V-90
  • Number of cores Multi Core
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

YJLV Cable is a low-voltage power cable with XLPE insulation and aluminum conductor, designed for fixed installations in industrial environments, urban distribution networks, and infrastructure projects. With a rated voltage of 0.6/1kV, it is widely used for power transmission and distribution where flexibility and cost-efficiency are key.

Applications

YJLV aluminum power cables are suitable for a wide range of applications:

  • Underground installations

  • Cable ducts and conduits

  • Indoor and outdoor power distribution

  • Power stations and transformer substations

  • Industrial control panels and distribution boards

  • Urban network and utility connections

⚠️ Not suitable for areas requiring resistance to mechanical damage.


Standards & Certifications

YJLV cables comply with major international standards, ensuring reliable quality and safety:

  • IEC 60502

  • HD 603.1 / VDE-0276 Part-603

  • IEC 60332-1 / DIN EN 60332-1-2 (Flame retardant)

  • CE LVD 73/23/EEC, 93/68/EEC


Construction Details

YJLV Aluminum Power Cable Construction

YJLV Aluminum Power Cable Construction

Conductor: Class 2 stranded Aluminium Conductor to HD383 Class 1 or Class 2
Insulation: XLPE insulation
Number of Cable Cores: 1-core,2-core,3-core,4-core,5-core,3+1-core,3+2 core,4+1 core
Sheath: PVC outer sheath

Key Features

  • 🔋 High Insulation Performance – XLPE insulation offers excellent thermal and electrical properties

  • 🔧 Lightweight and Cost-effective – Aluminum conductor reduces overall system cost

  • 🔥 Flame-retardant PVC sheath – Complies with IEC 60332-1 for fire safety

  • 🌧️ Weather-resistant – Suitable for outdoor installations without additional protection

  • 🛠️ Multiple core configurations – Flexible design for various application needs


Typical Applications by Industry

Industry Common Use Cases
Power & Utilities Transformer to panel, substation cabling
Construction & Real Estate Low-voltage mains for residential & commercial buildings
Industrial Plants Distribution panel wiring, motor circuits
Infrastructure Street lighting, public facility power supply
0.6/1kV-1 core aluminum conductor XLPE insulated PVC sheathed power cable
0.6/1kV-1 core aluminum conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross section Thickness of Insulation  Thickness of Sheath Approx. overall Diameter Approx. weight Max. DC resistance of conductor(20℃) Current carrying capacity
(mm2) (mm) (mm) (mm) (kg/km) (Ω/km) In Air(A) In Ground(A)
1X10 0.7 1.4 8.0 75 3.08 55 71
1X16 0.7 1.4 9.0 106 1.91 71 91
1X25 0.9 1.4 10.6 150 1.20 94 115
1X35 0.9 1.4 11.6 180 0.868 115 140
1X50 1.0 1.4 13.1 240 0.641 140 165
1X70 1.1 1.4 15.0 320 0.443 180 205
1X95 1.1 1.5 16.8 400 0.320 220 245
1X120 1.2 1.5 18.4 500 0.253 260 280
1X150 1.4 1.6 20.5 600 0.206 300 315
1X185 1.6 1.6 22.6 730 0.164 350 360
1X240 1.7 1.7 25.2 930 0.125 414 420
1x300 1.8 1.8 27.8 1140 0.100 485 475
1x400 2.0 1.9 31.4 1500 0.0778 570 545
1x500 2.2 2.0 34.9 1800 0.0605 670 620
1X630 2.4 2.2 39.1 2285 0.0469 790 705
0.6/1kV-2 core aluminum conductor XLPE insulated PVC sheathed power cable
0.6/1kV-2 core aluminum conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross section Thickness of Insulation  Thickness of Sheath Approx. overall Diameter Approx. weight Max. DC resistance of conductor(20℃) Current carrying capacity
(mm2) (mm) (mm) (mm) (kg/km) (Ω/km) In Air(A) In Ground(A)
2X10 0.7 1.8 15.4 200 3.08 58 78
2X16 0.7 1.8 17.4 270 1.91 75 100
2X25 0.9 1.8 20.5 380 1.20 100 130
2X35 0.9 1.8 22.5 480 0.868 120 155
2X50 1.0 1.8 20.3 490 0.641 150 185
2X70 1.1 1.8 23.3 630 0.443 190 225
2X95 1.1 1.9 26.2 820 0.320 235 275
2X120 1.2 2.0 29.4 1000 0.253 275 315
2X150 1.4 2.2 32.6 1250 0.206 315 350
2X185 1.6 2.3 36.0 1540 0.164 365 395
0.6/1kV-3 core aluminum conductor XLPE insulated PVC sheathed power cable
0.6/1kV-3 core aluminum conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross section Thickness of Insulation  Thickness of Sheath Approx. overall Diameter Approx. weight Max. DC resistance of conductor(20℃) Current carrying capacity
(mm2) (mm) (mm) (mm) (kg/km) (Ω/km) In Air(A) In Ground(A)
3X10 0.7 1.8 17.2 250 3.08 50 66
3X16 0.7 1.8 19.4 330 1.91 65 85
3X25 0.9 1.8 22.8 480 1.20 87 110
3X35 0.9 1.8 25.0 580 0.868 105 130
3X50 1.0 1.8 24.4 670 0.641 130 160
3X70 1.1 1.9 29.4 910 0.443 165 195
3X95 1.1 2.0 33.6 1170 0.320 205 235
3X120 1.2 2.1 35.9 1460 0.253 240 265
3X150 1.4 2.3 39.9 1820 0.206 270 300
3X185 1.6 2.4 44.1 2200 0.164 315 340
3X240 1.7 2.6 51.1 2850 0.125 375 395
3X300 1.8 2.7 56.1 3500 0.100 435 445
3X400 2.0 3.0 62.4 4500 0.0778 510 510
0.6/1kV-4 core aluminum conductor XLPE insulated PVC sheathed power cable
0.6/1kV-4 core aluminum conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross section Thickness of Insulation  Thickness of Sheath Approx. overall Diameter Approx. weight Max. DC resistance of conductor(20℃) Current carrying capacity
(mm2) (mm) (mm) (mm) (kg/km) (Ω/km) In Air(A) In Ground(A)
4X10 0.7 1.8 18.6 300 3.08 50 66
4X16 0.7 1.8 21.0 400 1.91 65 85
4X25 0.9 1.8 24.9 570 1.20 87 110
4X35 0.9 1.8 28.3 710 0.868 105 130
4X50 1.0 1.8 28.4 850 0.641 130 160
4X70 1.1 2.0 33.1 1160 0.443 165 195
4X95 1.1 2.1 37.1 1520 0.320 205 235
4X120 1.2 2.2 40.8 1898 0.253 240 265
4X150 1.4 2.4 45.2 2369 0.206 270 300
4X185 1.6 2.6 52.1 2925 0.164 315 340
4X240 1.7 2.8 57.8 3700 0.125 375 395
4X300 1.8 3.0 63.5 4580 0.100 435 445
4X400 2.0 3.3 70.9 5800 0.0778 510 510
0.6/1kV-5 core aluminum conductor XLPE insulated PVC sheathed power cable
0.6/1kV-5 core aluminum conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross section Thickness of Insulation  Thickness of Sheath Approx. overall Diameter Approx. weight Max. DC resistance of conductor(20℃) Current carrying capacity
(mm2) (mm) (mm) (mm) (kg/km) (Ω/km) In Air(A) In Ground(A)
5X10 0.7 1.8 18.8 360 3.08 50 66
5X16 0.7 1.8 21.8 485 1.91 65 85
5X25 0.9 1.8 26.2 690 1.20 87 110
5X35 0.9 1.8 28.0 865 0.868 105 130
5X50 1.0 1.9 32.4 1138 0.641 130 160
5X70 1.1 2.1 37.4 1575 0.443 165 195
5X95 1.1 2.2 41.7 2068 0.320 205 235
5X120 1.2 2.4 46.2 2550 0.253 240 265
5X150 1.4 2.6 53.1 3165 0.206 270 300
5X185 1.6 2.8 58.9 3950 0.164 315 340
5X240 1.7 3.0 65.6 5025 0.125 375 395
5X300 1.8 3.2 72.0 6190 0.100 435 445
0.6/1kV-3+1 core aluminum conductor XLPE insulated PVC sheathed power cable
0.6/1kV-3+1 core aluminum conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross section Thickness of Insulation  Thickness of Sheath Approx. overall Diameter Approx. weight Max. DC resistance of conductor(20℃) Current carrying capacity
(mm2) (mm) (mm) (mm) (kg/km) (Ω/km) In Air(A) In Ground(A)
3X16+1X10 0.7/0.7 1.8 19.4 370 1.91/3.08 65 85
3X25+1X16 0.9/0.7 1.8 22.8 520 1.20/1.91 87 110
3X35+1X16 0.9/0.7 1.8 25.1 650 0.868/1.91 105 130
3X50+1X25 1.0/0.9 1.8 28.2 780 0.641/1.20 130 160
3X70+1X35 1.1/0.9 1.9 31.9 1050 0.443/0.868 165 195
3X95+1X50 1.1/1.0 2.1 35.7 1460 0.320/0.641 205 235
3X120+1X70 1.2/1.1 2.2 39.6 1820 0.253/0.443 240 265
3X150+1X70 1.4/1.1 2.3 43.6 2150 0.206/0.443 270 300
3X185+1X95 1.6/1.1 2.5 49.8 2725 0.164/0.320 315 340
3X240+1X120 1.7/1.2 2.7 55.3 3480 0.125/0.253 375 395
3X300+1X150 1.8/1.4 2.9 57.0 4230 0.100/0.206 435 445
3X400+1X185 2.0/1.7 3.1 70.0 5520 0.0778/0.164 510 510
0.6/1kV-4+1 core aluminum conductor XLPE insulated PVC sheathed power cable
0.6/1kV-4+1 core aluminum conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross section Thickness of Insulation  Thickness of Sheath Approx. overall Diameter Approx. weight Max. DC resistance of conductor(20℃) Current carrying capacity
(mm2) (mm) (mm) (mm) (kg/km) (Ω/km) In Air(A) In Ground(A)
4X16+1X10 0.7/0.7 1.8 21.3 450 1.91/3.08 65 85
4X25+1X16 0.9/0.7 1.8 25.7 650 1.20/1.91 87 110
4X35+1X16 0.9/0.7 1.8 28.2 795 0.868/1.91 105 130
4X50+1X25 1.0/0.9 1.9 28.9 1020 0.641/1.20 130 160
4X70+1X35 1.1/0.9 2.0 32.2 1360 0.443/0.868 165 195
4X95+1X50 1.1/1.0 2.2 36.9 1870 0.320/0.641 205 235
4X120+1X70 1.2/1.1 2.3 40.8 2342 0.253/0.443 240 265
4X150+1X70 1.4/1.1 2.5 44.7 2778 0.206/0.443 270 300
4X185+1X95 1.6/1.1 2.7 50.7 3495 0.164/0.320 315 340
4X240+1X120 1.7/1.2 2.9 56.4 4416 0.125/0.253 375 395
4X300+1X150 1.8/1.4 3.1 64.0 5422 0.100/0.206 435 445
0.6/1kV-3+2 core aluminum conductor XLPE insulated PVC sheathed power cable
0.6/1kV-3+2 core aluminum conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross section Thickness of Insulation  Thickness of Sheath Approx. overall Diameter Approx. weight Max. DC resistance of conductor(20℃) Current carrying capacity
(mm2) (mm) (mm) (mm) (kg/km) (Ω/km) In Air(A) In Ground(A)
3X16+2X10 0.7/0.7 1.8 20.8 425 1.91/3.08 65 85
3X25+2X16 0.9/0.7 1.8 25.2 600 1.20/1.91 87 110
3X35+2X16 0.9/0.7 1.8 26.8 720 0.868/1.91 105 130
3X50+2X25 1.0/0.9 1.9 28.7 955 0.641/1.20 130 160
3X70+2X35 1.1/0.9 2.0 33.7 1230 0.443/0.868 165 195
3X95+2X50 1.1/1.0 2.2 38.3 1706 0.320/0.641 205 235
3X120+2X70 1.2/1.1 2.3 43.2 2180 0.253/0.443 240 265
3X150+2X70 1.4/1.1 2.4 46.5 2525 0.206/0.443 270 300
3X185+2X95 1.6/1.1 2.6 51.9 3195 0.164/0.320 315 340
3X240+2X120 1.7/1.2 2.8 58.0 4050 0.125/0.253 375 395
3X300+2X150 1.8/1.4 3.0 64.2 4983 0.100/0.206 435 445
Need Help?