N2XB2Y cable is a robust, medium-voltage power cable designed for underground and industrial applications where mechanical protection is essential but tensile loads are limited. With cross-linked polyethylene (XLPE) insulation and a steel tape armoured construction, this cable offers high durability and reliable electrical performance under demanding conditions.

  • N2xb2y Cable

N2XB2Y Cable


Power cable 0,6/1 kV with Cu conductors, XLPE insulated and HDPE sheathed

  • Rated Voltage 0.6/1kV
  • Conductor Material Plain annealed copper
  • Insulation Material XLPE
  • Sheath HDPE
  • Armour Double galvanized steel tape
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

N2XB2Y cable is a robust, medium-voltage power cable designed for underground and industrial applications where mechanical protection is essential but tensile loads are limited. With cross-linked polyethylene (XLPE) insulation and a steel tape armoured construction, this cable offers high durability and reliable electrical performance under demanding conditions.

Application

N2XB2Y cables are suitable for:

  • Underground installations, including direct burial

  • Ducts, cable trays, and concrete environments

  • Water-saturated areas, provided the cable is not under continuous tensile stress

  • Power distribution systems in:

    • Electrical substations

    • Transformer stations

    • Industrial plants

    • Urban infrastructure and energy networks

These cables are specifically engineered to withstand moderate mechanical impacts, making them ideal for installation conditions requiring mechanical protection without exposure to significant tensile stress.

Applicable Standards

  • IEC 60502-1

  • HD 603 S1

CONSTRUCTION :

 N2XB2Y Cable Construction

N2XB2Y Cable Construction

Conductor: Copper  Class 1: solid conductor, or Class 2: stranded conductor
Insulation:Cross-linked polyethylene XLPE
Filler: Non-hygroscopic material
Binder tape: Non-hygroscopic material
Inner sheath: Polyvinyl chloride PVC
Armour: Double galvanized steel tape
Outer sheath: HDPE

Key Features

  • Excellent mechanical protection via steel tape armouring

  • High thermal resistance due to XLPE insulation

  • Water-resistant construction for wet or semi-wet installations

  • Non-hygroscopic bedding and fillers improve durability

  • Halogen-containing sheath (PVC inner, HDPE outer) for cost-effective ruggedness

PARAMETER :

NOMINAL CROSS-SECTION MAX. RESISTANCE AT 20°C CURRENT CAPACITY IN AIR CURRENT CAPACITY IN EARTH OUTER DIAM. (APPROX.) CABLE WEIGHT (APPROX.)
mm² Ω/km A A mm kg/km
2x4 4,61 42 52 14,2 326
2x6 3,08 53 64 15,2 390
2x10 1,83 74 86 17,2 521
2x16 1,15 98 112 19,0 706
2x25 0,727 133 145 22,0 1001
2x35 0,524 162 174 24,2 1275
2x50 0,387 197 206 27,4 1729
2x70 0,268 250 254 31,4 2299
3x10 1830 74 86 18,0 637
3x16 1150 98 112 19,9 884
3x25 0,727 133 145 23,2 1275
3x35 0,524 162 174 24,5 1341
3x50 0,387 197 206 28,3 2044
3x70 0,268 250 254 32,5 2709
3x95 0,193 308 305 35,7 3493
3x120 0,153 359 348 39,1 4363
3x150 0,124 412 392 43,2 5336
3x185 0,0991 475 444 47,1 6470
3x240 0,0754 564 517 52,5 8185
4x10 1830 74 86 19,3 841
4x16 1150 98 112 21,5 1162
4x25 0,727 133 145 25,1 1671
4x35 0,524 162 174 27,1 1847
4x50 0,387 197 206 31,2 2741
4x70 0,268 250 254 35,8 3662
4x95 0,193 308 305 39,6 4821
4x120 0,153 359 348 43,4 5903
4x150 0,124 412 392 48,8 7290
4x185 0,0991 475 444 53,2 8815
4x240 0,0754 564 517 59,3 11194
5x10 1830 74 86 20,7 885,6
5x16 1150 98 112 23,1 1258,4
5x25 0,727 133 145 27,2 1847,4
5x35 0,524 162 174 30,2 2429,2
5x50 0,387 197 206 35,6 3545,1
5x70 0,268 250 254 40,7 4781,6
5x95 0,193 308 305 45,4 6287,1