4 Core Armoured Cable Copper Cu/XLPE/PVC/SWA/PVC BS5467 0.6/1kV

Our 4 Core Steel Wire Armoured (SWA) Cable with soft annealed copper conductors offers a highly durable and reliable solution for low voltage power distribution. Manufactured to comply with BS 5467 and IEC 60502-1 standards, this cable features XLPE insulation, robust Steel Wire Armour (SWA), and a protective PVC oversweath. With a rated voltage of 0.6/1kV, it is engineered for demanding indoor and outdoor applications requiring mechanical protection and reliable electricity supply.

  • 4 Core Armoured Cable Copper

4 Core Armoured Cable Copper Cu/XLPE/PVC/SWA/PVC BS5467 0.6/1kV


4 Core Armoured Cable Copper XLPE PVC SWA 0.6/1kV

  • Rated Voltage 600/1000 Volts
  • Conductor Material soft annealed copper
  • Insulation Cross Linked Poly Ethylene (XLPE)
  • Armour Steel Wire Armoured
  • Oversheath PVC
  • Number of cores 4 core


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

Our 4 Core Steel Wire Armoured (SWA) Cable with soft annealed copper conductors offers a highly durable and reliable solution for low voltage power distribution. Manufactured to comply with BS 5467 and IEC 60502-1 standards, this cable features XLPE insulation, robust Steel Wire Armour (SWA), and a protective PVC oversweath. With a rated voltage of 0.6/1kV, it is engineered for demanding indoor and outdoor applications requiring mechanical protection and reliable electricity supply.


Applications

This 4 Core SWA Armoured Cable is versatile and commonly used for electricity supply in low voltage installation systems across various environments:

  • Underground Installations: Suitable for direct burial, with the steel wire armouring providing enhanced protection from external mechanical damage.
  • Power Networks: Ideal for general power distribution and fixed installations.
  • Incoming Mains Supply: Frequently used for incoming mains electricity to homes, commercial buildings, and industrial sites.
  • Indoor & Outdoor Use: Designed for installation in diverse locations, including:
    • Cable ducts
    • Power and switching stations
    • Local energy distribution systems
    • Industrial plants
  • Areas without Mechanical Damage Risk: While armoured for protection, these cables are robust enough for general use where reliable power is needed.

The XLPE insulation provides excellent resistance to various fluids and chemicals, good heat stability, and is UV resistant, further enhancing the cable's longevity and reliability.


Standards Compliance

Our 4 Core SWA Armoured Cables are manufactured and tested to comply with or exceed the requirements of the following international and British standards:

  • BS 5467: Electric cables. Thermosetting insulated, armoured cables for voltages of 600/1000 V and 1900/3300 V.
  • IEC/EN 60502-1: Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV) - Part 1: Cables for rated voltages of 1 kV (Um=1.2kV) and 3 kV (Um=3.6kV).
  • IEC/EN 60228: Conductors of insulated cables (specifies conductor types: plain circular, compacted, or shaped stranded copper or aluminium).
  • Flame Retardancy: Compliant with IEC/EN 60332-1-2 (single vertical insulated wire or cable).

CONSTRUCTION :

4 Core SWA Armoured Cable Construction

4 Core SWA Armoured Cable Construction

4 Core SWA Armoured Cable Construction

TECHNICAL DATA :
4 Core SWA Armoured Cable Technical Data

STANDARD IEC 60502-1, BS 5467 and BS 6346
APPLICATION Distribution networks, Industrial use
CHEMICAL PERFORMANCE Chemical & Oil resistance: Good
MECHANICAL PERFORMANCE Minimum bending raduis: x15cable diameter (unarmoured)
Minimum bending raduis: x20 cable diameter (armoured)
FIRE PERFORMANCE Flame non-propagation base on IEC 60332-1
Reduced emission of Halogens chlorine<15%
TERMINAL PERFORMANCE Maximum service temperature: 90°C
Maximum short-circuit temperature: 150°C(max. 5s)
Minimum service temperature: -40°C
4 Core SWA Armoured Cable XLPE Insulated Parameter
Type Specification Outer diameter Nominal
thickness
of insulation
Diameter of
steel wire
Nominal
sheath
thickness
Approx.
Outer
diameter
of cable
Approx. Weight
of cable
Ampacity of cable
Air Soil
CU AL Cu Al Cu Al
XLPE/SWA mm2 mm mm mm mm mm kg/km kg/km A A A A
4×4 RE 2.24 0.7 1.25 1.8 19.1 770 670 37 28 46 35
4×6 RE 2.76 0.7 1.25 1.8 20.3 916 772 47 37 56 46
4×10 CC 3.8 0.7 1.6 1.8 22.3 1148 895 64 47 76 56
4×16 CC 4.8 0.7 1.6 1.8 24.5 1472 1070 84 64 98 76
4×25 CC 6.0 0.9 1.6 1.8 27.5 1942 1317 115 84 126 98
4×35 CC 7.0 0.9 1.6 1.8 29.5 2386 1521 141 115 152 126
4×50 SM 8.0 1.0 2.0 1.9 32.9 3209 2036 172 141 181 152
4×70 SM 9.5 1.1 2.0 2.1 36.7 4197 2502 218 172 222 181
4×95 SM 11.0 1.1 2.0 2.3 40.5 5362 3016 269 218 267 222
4×120 SM 12.4 1.2 2.5 2.4 45.3 6908 3940 313 269 305 267
4×150 SM 13.8 1.4 2.5 2.6 50.0 8327 4683 359 313 344 305
4×185 SM 15.4 1.6 2.5 2.7 54.2 10044 5466 405 359 383 344
4×240 SM 17.5 1.7 2.5 2.9 60.4 12672 6666 451 405 442 383
4×300 SM 19.6 1.8 2.5 3.1 65.7 15302 7795 497 451 461 422