Outdoor Weather-proof PVC Insulated Wire OW

Outdoor Weather-proof PVC Insulated Wire (OW) is specially designed for outdoor applications where exposure to weather elements such as rain, sunlight, and temperature fluctuations is a concern. It features robust PVC insulation that provides excellent resistance to moisture, UV rays, and environmental stress, ensuring long-term durability and safety. Ideal for outdoor wiring in gardens, outdoor lighting, and other exposed electrical installations, this wire ensures reliable performance and protection against the elements, maintaining electrical integrity over time.

  • Outdoor Weather Proof Pvc Insulated Wire Ow

Outdoor Weather-proof PVC Insulated Wire OW


Wire OW

  • Conductor Material Copper Conductor
  • Insulation PVC
  • Voltage 450/450V
  • Number of cores Single Core
  • Package Export Wooden Case & Pallet


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

Outdoor Weather-proof PVC Insulated Wire OW Application

– Used in low-voltage manufactured electrical cables. Uses hard-drawn copper wires for electrical use as the conductor and is sheathed in PCV, making it more durable than previous insulated cables.

Outdoor Weather-proof PVC Insulated Wire OW Standards:

KS 3331

CONSTRUCTION :

Outdoor Weather-proof PVC Insulated Wire OW Construction
– Conductor : Hard-drawn copper wire for electrical use
– Insulator : PVC
– Insulator color : Black
– Highest temperature : 70 ℃

SOLID CONDUCTOR :
Conductor Nominal
Insulation
Thickness
Overall
Diameter
Max.
Conductor
Resistance
at 20℃
Test
Voltage
Min.
Tensile
Load
Approx.
Weight
Standard
Length
Diameter Nominal
Sectional
Area
mm mm2 mm mm Ω/km V/5min N kg/km m
2.0 3.142 0.4 2.8 5.83 2500 1,310 32 300
2.6 5.309 0.5 3.6 3.45 2500 2,180 54 300
3.2 8.042 0.6 4.4 2.28 2500 3,260 81 200
4.0 12.57 1.0 6.0 1.46 2500 4,890 135 200
5.0 19.64 1.2 7.4 0.932 2500 7,450 210  200  
STRANDED CONDUCTOR :
Conductor Nominal
Insulation
Thickness
Overall
Diameter
Max.
Conductor
Resistance
at 20℃
Test
Voltage
Min.
Tensile
Load
Approx.
Weight
Standard
Length
Nominal
Sectional
Area
Number &
Diameter
of Wire
Outer
Diameter
mm2 No./mm mm mm mm Ω/km V/5min N kg/km m
14 7/1.6 4.8 1.0 6.8 1.35 2500 5,620 160 300
22 7/2.0 6.0 1.2 8.4 0.849 2500 8,710 250 300
38 7/2.6 7.8 1.4 11.0 0.502 2500 14,500 410 300
60 19/2.0 10.0 1.4 13.0 0.313 2500 23,600 630 300
100 19/2.6 13.0 1.5 16.0 0.185 2500 39,300 1030 300
Need Help?