ABC Aluminum Aerial Bundle Cables AS/NZS 3560.1

ABC (Aerial Bundle Cables) Aluminum Aerial Bundle Cables are specifically engineered for overhead distribution line applications. These cables feature aluminum 1350 conductors with XLPE insulation, providing reliable power transmission for fixed overhead power line installations up to 1000V. The bundled design offers superior performance, safety, and installation convenience compared to traditional bare conductor systems.

  • Abc Aluminum Aerial Bundle Cables 3560.1

ABC Aluminum Aerial Bundle Cables AS/NZS 3560.1


ABC Aluminum Aerial Bundle Cables AS/NZS 3560.1

  • Voltage 0.6/1kV
  • Conductor 1350 Aluminum Conductor
  • Insulation XLPE
  • Number of cores 2-5 cores
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

ABC (Aerial Bundle Cables) Aluminum Aerial Bundle Cables are specifically engineered for overhead distribution line applications. These cables feature aluminum 1350 conductors with XLPE insulation, providing reliable power transmission for fixed overhead power line installations up to 1000V. The bundled design offers superior performance, safety, and installation convenience compared to traditional bare conductor systems.

Standards Compliance

  • Australian/New Zealand Standard: AS/NZS 3560.1

CONSTRUCTION :

ABC Aluminum Aerial Bundle Cables AS NZS 3560.1 Construction

ABC Aluminum Aerial Bundle Cables AS NZS 3560.1 Construction

Conductor Design

  • Material: Aluminum 1350 alloy wires
  • Construction: Compacted circular stranded (RM) configuration
  • Application: Suitable for phase conductors, neutral conductors, and street lighting circuits

Insulation System

  • Material: Cross-Linked Polyethylene (XLPE)
  • Benefits: Superior electrical properties, weather resistance, and long-term durability

Cable Assembly

  • Lay Configuration: Cores are laid up with left-hand lay for optimal mechanical strength
  • Bundle Design: Multiple insulated conductors bundled together for enhanced safety and reduced maintenance

 

Technical Specifications

Electrical Ratings

Parameter Value Unit
Rated Voltage 0.6/1 kV
Test Voltage 4/50 Veff kV/Hz

Temperature Characteristics

Parameter Range Unit
Laying Temperature Minimum -5 °C
Operating Temperature -30 to +90 °C
Maximum Conductor Temperature +90 °C
Short-circuit Temperature Maximum +250 for 5 seconds °C/s

Physical Properties

Parameter Specification
Minimum Bending Radius 15 × cable diameter

Parameter

No. of Core
& Size
Phase Core Neutral Core Complete Cable
No. &
Section Area
No. of Wire Dia. of Conductor
(Approx.)
Insulation
Thickness
No. & Section Area No. of Wire Dia. of Conductor
(Approx.)
Insulation
Thickness
Overall Dia.
(Approx.)
Weight
(Approx.)
mm2 mm2 No. mm mm mm2 No. mm mm mm kg/km
2x16 1x16 7 4.7 1.3 1x16 7 4.7 1.3 14.6 132
4x16 3x16 7 4.7 1.3 1x16 7 4.7 1.3 17.6 263
2x25 1x25 7 6.0 1.3 1x25 7 6.0 1.3 17.2 189
3x25 2x25 7 6.0 1.3 1x25 7 6.0 1.3 18.5 283
4x25 3x25 7 6.0 1.3 1x25 7 6.0 1.3 20.8 378
2x35 1x35 7 7.0 1.3 1x35 7 7.0 1.3 19.2 249
3x35 2x35 7 7.0 1.3 1x35 7 7.0 1.3 20.7 373
4x35 3x35 7 7.0 1.3 1x35 7 7.0 1.3 23.2 497
2x50 1x50 7 8.1 1.5 1x50 7 8.1 1.5 22.2 334
3x50 2x50 7 8.1 1.5 1x50 7 8.1 1.5 23.9 501
4x50 3x50 7 8.1 1.5 1x50 7 8.1 1.5 26.8 668
4x70 3x70 19 10.0 1.5 1x70 19 10.0 1.5 31.4 933
2x95 1x95 19 11.6 1.7 1x95 19 11.6 1.7 30.0 638
4x95 3x95 19 11.6 1.7 1x95 19 11.6 1.7 36.2 1276
4x120 3x120 19 13.0 1.7 1x120 19 13.0 1.7 39.6 1579
4x150 3x150 19 14.6 1.7 1x150 19 14.6 1.7 43.5 1883