SIP-4 Cable

The SIP-4 cable is a type of Self-supporting Insulated Overhead Wire used for low-voltage power distribution. Its name is an acronym for Self-supporting Insulated Polar wire, with "4" denoting its specific design type. A key feature of SIP-4 is that it does not have a separate messenger (load-bearing) wire; all the insulated conductors are self-supporting. The conductors are made of compacted aluminum and insulated with XLPE (cross-linked polyethylene).

  • Sip 4 Cable

SIP-4 Cable


Self-supporting Insulated Overhead Wire Cable SIP-4

  • Voltage 0.6/1kV
  • Conductor Aluminum Conductor
  • Insulation XLPE
  • Number of cores 2-5 cores
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

The SIP-4 cable is a type of Self-supporting Insulated Overhead Wire used for low-voltage power distribution. Its name is an acronym for Self-supporting Insulated Polar wire, with '4' denoting its specific design type. A key feature of SIP-4 is that it does not have a separate messenger (load-bearing) wire; all the insulated conductors are self-supporting. The conductors are made of compacted aluminum and insulated with XLPE (cross-linked polyethylene).

Applications

SIP-4 cables are versatile and used for a variety of low-voltage distribution purposes, including:

  • Powering end-consumer facilities and residential areas.
  • Building lighting power grids.
  • Laying on the walls of construction sites.
  • Equipping branches from overhead power lines to transformer units.

Unlike other ABC cables that rely on a separate neutral messenger wire for support, SIP-4 relies on the combined strength of all its conductors. This makes installation faster and simpler in some cases.

SPECIFICATION :

Specifications
Permissible heating temperature of current-carrying conductors during overload mode (up to 8 hours per day) 130°С
Permissible heating temperature of current-carrying conductors in case of short circuit with short circuit current flow up to 5 seconds 250°С
Operating temperature от -60 °С до +50 °С
Minimum wire laying temperature -20 °С
Long-term permissible core heating temperature +90 °С
Minimum bending radius when laying 10 wire diameters
Minimum service life 25 years

Parameter

Number and nominal cross-section of conductors, mm2 Outer wire diameter, mm Estimated weight of 1 km of wire / 1kg Nominal insulation thickness
SIP-4 2х16 17.2 142.6 1.3
SIP-4 2х25 19.8 205.5 1.3
SIP-4 3х16 15.7 206 1.3
SIP-4 3х25 18.1 292 1.3
SIP-4 4х16 20.08 285.3 1.3
SIP-4 4х25 23.9 410.9 1.3
SIP-4 4х35 27.1 544.7 1.3
SIP-4 4х50 30.9 730.8 1.5
SIP-4 4х70 35.6 1014.1 1.7
SIP-4 4х95 41.5 1358.5 1.7
SIP-4 4х120 45.2 1683.2 1.7