12.7/22kV Screened MV ABC Cable–Aerial Bundled Cables to AS/NZS 3599.1 (AL/XLPE /CWS/HDPE)

This is a medium-voltage (MV) Aerial Bundled Cable (ABC) designed for overhead power distribution, built to the AS/NZS 3599.1 standard. Its construction is defined by its materials: AL (aluminum conductor), XLPE (insulation), CWS (copper wire screen), and HDPE (sheath). The cable features a screened design for higher voltage applications, with three insulated cores bundled around a galvanized steel support wire.

  • Screened Mv Abc Cable–aerial Bundled Cables 2

12.7/22kV Screened MV ABC Cable–Aerial Bundled Cables to AS/NZS 3599.1 (AL/XLPE /CWS/HDPE)


12.7/22kV Screened MV ABC Cable–Aerial Bundled Cables to AS/NZS 3599.1 (AL/XLPE /CWS/HDPE)

  • Conductor Compact stranded hard drawn Aluminium Conductor ( Class2)
  • Conductor Screen Extruded semi-conductive layer
  • Insulation Cross-linked polyethylene (Natural)
  • Insulation Screen Extruded semi-conductive layer
  • Metallic Screen Copper wire screen
  • Sheath HDPE


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

This is a medium-voltage (MV) Aerial Bundled Cable (ABC) designed for overhead power distribution, built to the AS/NZS 3599.1 standard. Its construction is defined by its materials: AL (aluminum conductor), XLPE (insulation), CWS (copper wire screen), and HDPE (sheath). The cable features a screened design for higher voltage applications, with three insulated cores bundled around a galvanized steel support wire.

Screened MV ABC Cable Construction

Phase Conductor Circular Compacted Stranded H68 Aluminium ( Class 2)
Conductor Screen Extruded Semi-conductive Layer.
Insulation XLPE.
Insulation Screen Extruded Semi-conductive Layer.
Metallic Screen Copper wire screen or copper tape screen
Separator Semi-conductive swellable tape.
Outer Sheath HDPE.
Support Conductor Galvanized steel wires.
Assembly XLPE insulated screened cores are bundled around the galvanized steel wires in a right hand lay

Screened MV ABC Cable Construction

Screened MV ABC Cable Construction

Applications and Technical Data

This cable is used for medium-voltage overhead distribution in applications like secondary overhead lines on poles or as feeders to residential premises. It is a new type of aerial cable used to transmit electric power overhead, improving the safety and reliability of electrified wire networks, particularly in urban and forest regions.

  • Normal Operating Temperature: C.
  • Emergency Overload Temperature: C.
  • Short Circuit Temperature: C.

12.7/22kV Screened MV ABC Cable (AL/XLPE /CWS/HDPE) Parameter

Number of Cores x Nominal Cross Section Nominal Conductor Diameter Nominal Insulation Thickness Nominal Insulation Screen Thickness Copper Wire Screen Stranding Nominal Sheath Thickness Galvanized Steel Wire Stranding Nominal Overall Diameter Weight Continuous current rating, A
Still air 1m/s wind 2m/s wind
mm^2 mm mm mm No/mm mm No/mm mm kg/km A A A
Light duty screen
3x35 6.9 5.5 0.8 25/0.85 1.8 7/2.00 62.7 2280 100 140 165
3x35 6.9 5.5 0.8 25/0.85 1.8 19/2.00 66.7 2580 105 145 165
3x50 8.1 5.5 0.8 25/0.85 1.8 19/2.00 69.0 2780 125 170 200
3x70 9.7 5.5 0.8 25/0.85 1.8 19/2.00 72.6 3110 150 215 250
3x95 11.4 5.5 0.8 25/0.85 1.8 19/2.00 76.0 3460 180 260 305
3x120 12.8 5.5 0.8 25/0.85 1.8 19/2.00 79.2 3810 205 300 355
3x150 14.2 5.5 0.8 25/0.85 1.9 19/2.00 82.8 4230 230 340 400
3x185 15.7 5.5 0.8 25/0.85 1.9 19/2.00 86.2 4650 265 390 460
Heavy duty screen
3x35 6.9 5.5 0.8 40/0.85 1.8 7/2.00 62.7 2510 100 140 165
3x35 6.9 5.5 0.8 40/0.85 1.8 19/2.00 66.7 2810 105 145 165
3x50 8.1 5.5 0.8 23/1.35 1.8 19/2.00 71.0 3300 125 175 200
3x70 9.7 5.5 0.8 32/1.35 1.9 19/2.00 74.6 3970 155 215 250
3x95 11.4 5.5 0.8 39/1.35 1.9 19/2.00 78.0 4600 180 260 305
3x120 12.8 5.5 0.8 39/1.35 2.0 19/2.00 81.2 4950 205 300 355
3x150 14.2 5.5 1.0 39/1.35 2.0 19/2.00 84.8 5360 230 340 395
3x185 15.7 5.5 1.0 39/1.35 2.1 19/2.00 88.2 5790 265 390 400 