3-Layer 25kV ACSR Tree Wire Spacer Cable

This is a specialized covered conductor for medium-voltage overhead power distribution. The 3-Layer 25kV ACSR Tree Wire Spacer Cable has a multi-layered protective covering that prevents direct shorts and flashovers from contact with trees or other objects. It's an ideal choice for areas where space is limited or where lines pass through wooded regions.

  • 3 Layer 25kv Acsr Tree Wire Spacer Cable

3-Layer 25kV ACSR Tree Wire Spacer Cable


3-Layer 25kV ACSR Tree Wire Spacer Cable

  • Conductor ACSR
  • Insulation Cross-linked polyethylene(XLPE)
  • Sheath High-density track-resistant Polyethylene(HDPE)
  • Package Export wooden drum & iron wooden drum or as customer require


Conatact us


Name


Email


Phone


Message


Congratulations. Your message has been sent successfully.
Error, please retry. Your message has not been sent.

This is a specialized covered conductor for medium-voltage overhead power distribution. The 3-Layer 25kV ACSR Tree Wire Spacer Cable has a multi-layered protective covering that prevents direct shorts and flashovers from contact with trees or other objects. It's an ideal choice for areas where space is limited or where lines pass through wooded regions.


Key Specifications & Construction

  • Voltage: 25 kV phase-to-phase.
  • Conductor: Concentrically stranded Aluminum Conductor Steel-Reinforced (ACSR), providing a combination of high strength and good conductivity. Other conductor types like AAC or AAAC are also available.
  • Layers: The 3-layer design consists of a semi-conducting layer, primary insulation, and a final protective outer layer.
  • Insulation: The primary insulating layer is cross-linked polyethylene (XLPE).
  • Sheath: The outermost layer is a high-density track-resistant polyethylene (HDPE).
  • Standards: The cable complies with ICEA S-121-733, ASTM B231, ASTM B399, and ASTM B232.

 

Technical Data

  • Normal Operating Temperature: C.
  • Emergency Overload Temperature: C.
  • Short Circuit Temperature: C.
  • AC Testing Voltage: The cable is tested at a voltage suitable for a 25 kV rating.

Parameter Table

Size (AWG or kcmil) Stranding Conductor Diameter (mils) Covering Thickness (mils) Cable O.D. (mils) Rated Strength (lbs) Weight per 1000 ft (lbs)
1/0 6/1 398 15/125/125 928 4161 385
2/0 6/1 447 15/125/125 977 5045 443
3/0 6/1 502 15/125/125 1032 6289 513
4/0 6/1 563 15/125/125 1093 7933 600
266.8 18/1 609 15/125/125 1139 6536 660
266.8 26/7 642 15/125/125 1172 10735 692
336.4 18/1 684 15/125/125 1214 8246 714
336.4 26/7 720 15/125/125 1250 13395 818
336.4 30/7 741 15/125/125 1271 16435 1086
397.5 18/1 743 15/125/125 1273 9443 804
397.5 24/7 772 15/125/125 1302 13870 863
397.5 26/7 783 15/125/125 1313 15485 926
477 24/7 846 20/125/125 1386 16340 999
477 26/7 858 20/125/125 1398 18525 1076
477 30/7 883 20/125/125 1423 22610 1458
556.5 18/1 879 20/125/125 1419 13015 1045
556.5 24/7 914 20/125/125 1454 18810 1124
556.5 26/7 927 20/125/125 1467 21470 1213