Aluminum XHHW SER SEU RHH RHW-2 XLP USE-2 Cable

The name "Aluminum XHHW SER SEU RHH RHW-2 XLP USE-2 Cable" isn't a single product; it's a list of various cable types and their characteristics. All of them generally refer to aluminum conductors with XLPE (Cross-Linked Polyethylene) insulation. They are all rated for 600V and are commonly used for secondary distribution and service entrance applications.

Aluminum XHHW SER SEU RHH RHW-2 XLP USE-2 Cable is primarily used for secondary distribution and underground service at 600 volts or less, either directly burial or in ducts, where increased flexibility is needed.


Aluminum XHHW-2 Wire 600 Volts

Aluminum XHHW-2 Wire 600 Volts

Conductor: 8000 Series Aluminum Alloy
Insulation: Cross-linked polyethylene insulation (XLPE)
Voltage: 600V

Quote Now

The name 'Aluminum XHHW SER SEU RHH RHW-2 XLP USE-2 Cable' isn't a single product; it's a list of various cable types and their characteristics. All of them generally refer to aluminum conductors with XLPE (Cross-Linked Polyethylene) insulation. They are all rated for 600V and are commonly used for secondary distribution and service entrance applications.

  • Conductor: The cables feature a lightweight and cost-effective aluminum conductor.
  • Insulation: They use XLPE insulation, a high-performance material with excellent resistance to heat, moisture, ozone, and chemical corrosion.
  • Voltage Rating: All are rated for 600V.
  • Application: These cables are suitable for secondary distribution and service entrance, and can be directly buried or installed in conduits.

Understanding the Different Cable Types

AcronymFull NamePrimary Use & Features
XHHWXLPE High Heat Water-resistantA versatile single-conductor wire for general wiring. It's suitable for wet or dry locations with a maximum operating temperature of C.
RHH / RHW-2Rubber Heat / Rubber Heat and Water-resistantThese are historical standards, but the term often refers to cables with XLPE insulation that meet the same heat and moisture resistance requirements. The '-2' indicates a C rating for wet locations, making it robust for direct burial.
USE-2Underground Service EntranceA cable specifically designed for direct burial and use as service entrance cable. The '-2' designation means it has a C rating for wet locations.
SERService Entrance RoundA jacketed cable with two or more insulated conductors and a bare neutral. It's typically used for interior wiring from a service panel to branch circuits.
SEUService Entrance UprightSimilar to SER, this cable has a flat profile and a concentric neutral conductor. It's often used for service entrance runs from a meter base to the service panel.